PCD-430A
Sensor Interface

  • CE
  • TEDS

PCD-430A

Summary

· Input signals of strain or voltage can be selected channel by channel
· Synchronous sampling in 4 units connected by an optional Connection Connector Set
· TEDS compliant if Input Adapter UI-10A or UI-11A is used
· Max sampling frequency 10 kHz

Features

The PCD-430A is a carrier-wave measuring instrument for connecting strain gages, strain-gage transducers and voltage. Up to 16 channels is possible, simply dock 4 units.

Products table

All display

PCD-430A
Sensor Interface

PCD-430A
  • CE
  • TEDS

General specifications

Input Channels 4
Synchronous Measurement Up to 4 units by 16 channels
Sampling Sampling Frequencies : Maximum 10 kHz (Synchronous sampling of 4 units 16 channels)
A/D Resolution 24 bits
Holding Setting Conditions Range, Balance adjustment are stored in internal nonvolatile memory.
TEDS Loading function from the TEDS sensor
channel name writing function (For the manufacture ID: KYOWA only)
Interfaces USB 2.0 (Compliant to the High-Speed, USB 3.0 port supported)
Operating Temperature/Humidity 0 to 40ºC, 20 to 85% RH (Noncondensing)
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 200 Hz (12 cycles for each axis, 10 minutes/cycle)
Power Supply 11 to 16 VDC
Connector: RM12BRD-4PH (Hirose)
Current Consumption 0.9 A or less (12 VDC)
Dimensions 210 W x 35 H x 157.5 D mm (Excluding Protrusions)
Weight Approx. 750 g
EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581

Strain Measurement Mode

Applicable Sensors Strain gages, Strain-gage transducers
Applicable Gage Resistance Quarter bridge system
(2-wire and 3-wire): 120 Ω
Half bridge system: 120 to 1000 Ω
Full bridge system: 120 to 1000 Ω
Input Types Balanced Differential Input
Bridge Power Supply 2 VACrms
Gage Factor 2.00 Fixed
Balance Adjustment Resistance: Within ±2% (±10000 μm/m)
Capacity: Within 5000 pF
Balance Adjustment Methods Resistance: Auto balance
Capacity: CST method (Automatic tracking)
Nonlinearity Within ±0.1% FS
Measurement Range 200, 500, 1 k, 2 k, 5 k, 10 k, and 20 k μm/m, 7 steps
Accuracy: Within ±0.5% FS
Frequency Response DC to 200 Hz, deviation within ±10%
LPF Transfer Characteristics : 2nd order Butterworth
Cutoff Frequency : 10, 30, 100 Hz, and FLAT, 4 steps
Amplitude Ratio at Cutoff Point : -3±1 dB
Attenuation : -12±1 dB/oct.
Stability Temperature
Zero point: ±0.2 μm/m per ºC
Sensitivity: ±0.05%/ºC
Time
Zero point: ±0.5 μm/m/8h
Sensitivity: ±0.15%/8h
Withstand Voltage Input-case, 250 VAC, 1 min.

Voltage Measurement Mode

Input Types Unbalanced Input
Measurement Range 1, 2, 5, 10, 20, and 50 V, 6 steps
Accuracy: Within ±0.2% FS
Frequency Response DC to 1 kHz,
Deviation: within -3 to + 1 dB
HPF Cutoff Frequency : 0.2 Hz, OFF
LPF Transfer Characteristics : 2nd order Butterworth
Cutoff Frequency : 10, 30, 100, 300 Hz and FLAT, 5 steps
Amplitude Ratio at Cutoff Point : -3±1 dB
Attenuation : -12±1 dB/oct.
Stability Temperature
Zero point: ±0.008%FS/ºC
Sensitivity: ±0.02%/ºC
Time
Zero point: ±0.03%FS/8h
Sensitivity: ±0.1%/8h
Standard Accessories USB cable N-38 (1 m)
Ground wire P-72 (5 m)
DVD (Dynamic data acquisition software DCS-100A)
Optional Accessories AC adapter UIA345-12 (For USA:UNI345-1238)
USB cable N-39 (2 m)
DC power cable P-76 (11 to 16 VDC, 2 m)
Connection cable N-97 (10cm)
Stacking connector set ST-1A
Stack fixture CN-20
Input adapter for strain gage transducer UI-10A (TEDS compatible)
Input adapter for strain gage UI-11A (TEDS compatible)
Input adapter for strain gage with operating lever UI-15A
One-touch lock type input adapter for strain gage UI-16 A
One-touch type input adapter UI-55A
Voltage input adapter UI-30A

UI-10A
Input Adapter for Strain Gage Transducers

  • TEDS
Product name Input adapter for strain gage transducers
Object Product Model PCD-300 Series, PCD-400A/430A

Specifications

Connecting Targets strain gage transducer
Number of Input Channels 4

UI-11A
Input Adapter for Strain Gages

UI-11A
  • TEDS
Product name Input adapter for strain gages
Object Product Model PCD-300 Series, PCD-400A/430A

Specifications

Connecting Targets strain gage, strain gage transducer
Strain Method quater bridge system (2-wire and 3-wire), half bridge system, full bridge system
Number of Input Channels 4

UI-15A
Input Adapter with Operating Levers for Strain Gages

UI-15A
Product name Input adapter with operating levers for strain gages
Object Product Model PCD-300 Series, PCD-400A/430A

Specifications

Connecting Targets strain gage, strain gage transducer
Strain Method quarter bridge system (2-wire and 3-wire), half bridge system, full bridge system
Number of Input Channels 4

UI-55A
One-touch Type Input Adapter

UI-55A
Product name One-touch type input adapter
Object Product Model PCD-400A/430A
EDX-11A( Full bridge system only)

Specifications

Connecting Targets strain gage, strain gage transducer
Strain Method quarter bridge system (2-wire and 3-wire), half bridge system, full bridge system
Number of Input Channels 4
Dimensions 105(W)×18.5(H)×35(D)mm
Weight Approx. 90g

UI-30A
Voltage input adapter

Product name Voltage input adapter
Object Product Model PCD-300 Series, PCD-430A

UI-16B
One-touch Type Input Adapter for Strain Gages

UI-16B
Product name One-touch type input adapter for strain gages
Object Product Model PCD-300 Series, PCD-400A/430A

Specifications

Connecting Targets strain gage, strain gage transducer
Strain Method quarter bridge system (2-wire and 3-wire), half bridge system, full bridge system
Number of Input Channels 4

Page Top

Download