EDX Series Conditioner Cards

  • CE
  • TEDS

Conditioner Cards

Summary

· Conditioner cards for EDX-100A, EDX-200A, and EDX-5000A.
· EDX-5000A does not support CAN card CAN-41A.

Features

The Cards are for measuring strain, voltage, acceleration, and temperature. CAN data is supported. Isolated amplifier cards and carrier-wave amplifier cards also available for countermeasure against noise.

Products table

All display

CDV-40B
Strain/Voltage Measurement Card

CDV-40B-F
  • CE
  • TEDS

Specifications

Channels 8 (Integrated connector)
Input Modes Strain Measurement: Balanced differential.
Voltage Measurement: Unbalanced
Input Resistance Strain Measurement: Approx. (10 + 10 MΩ)
Voltage Measurement: Approx. 1 MΩ
Coupling DC/AC (DC cut)
Applicable Gage Factor 2.00
Bridge Excitation 2 VDC ±2% (120 to 1k Ω )
Balance Adjustment Resistance ±2.4% (±12000 ×10-6 strain)
Measuring Range Strain Measurement: 500, 1 k, 2 k, 5 k, 10 k, 20 k, 50 k ×10-6 strain, OFF
Voltage Measurement: 0.1, 0.2, 0.5, 1, 2, 5, 10 V, OFF
Range Accuracy ±0.2% FS, each range
Calibration ±100%, ±50% of each range
Nonlinearity ±0.1%FS
Frequency Response DC coupling: DC to 50 kHz, deviation: 1 to -3 dB
AC coupling (DC cut): 0.2, 1 Hz to 50 kHz (See the HPF)
LPF Transfer characteristics : 2nd order Butterworth
Cutoff frequencies : 8 steps of 10, 30, 100, 300, 1 k, 3 k, 10 k [Hz] and FLAT
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
HPF (DC cut) Cutoff frequencies: 0.2, 1 Hz
Attenuation: -6 dB/oct.
A/D Converter 16 bits
TEDS Reading of information using TEDS built-in sensors.
EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581
Optional Accessories 8-channel input cable U-38 to U-48
Note If the transducer with a remote-sensing function, a 4-conductor extension cable cable (N-81 to N-85) enables measurement. But the remote-sensing function will be ineffective.
Conversion adapter FV-1A

CDV-40B-F
Strain/Voltage Measurement Card, with Antialiasing LPF

CDV-40B-F
  • CE
  • TEDS

Specifications

Channels 8 (Centralized connector)
Input Modes Strain Measurement: Balanced differential.
Voltage Measurement: Unbalanced
Input Resistance Strain Measurement: Approx. (10 + 10 MΩ)
Voltage Measurement: Approx. 1 MΩ
Coupling DC/AC (DC cut)
Applicable Gage Factor 2.00
Bridge Excitation 2 VDC ±2% (120 to 1k Ω )
Balance Adjustment Resistance ±2.4% (±12000 ×10-6 strain)
Measuring Range Strain Measurement: 500, 1 k, 2 k, 5 k, 10 k, 20 k, 50 k ×10-6 strain, OFF
Voltage Measurement: 0.1, 0.2, 0.5, 1, 2, 5, 10 V, OFF
Range Accuracy ±0.2% FS, each range
Calibration ±100%, ±50% of each range
Nonlinearity ±0.1%FS
Frequency Response DC coupling: DC to 50 kHz, deviation: 1 to -3 dB
AC coupling (DC cut): 0.2, 1 Hz to 50 kHz (See the HPF)
LPF Transfer characteristics : 2nd order Butterworth
Cutoff frequencies : 8 steps of 10, 30, 100, 300, 1 k, 3 k, 10 k [Hz] and FLAT
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
Antialiasing LPF Transfer characteristics : 8th order Butterworth
Cutoff frequencies : Automatically set at sampling frequencies x 0.25
Attenuation : -48 dB±5 dB (At sampling frequency x 0.5)
Note: Available when the LPF is set to AUTO on the DCS-100A.
HPF (DC cut) Cutoff frequencies: 0.2, 1 Hz
Attenuation: -6 dB/oct.
A/D Converter 16 bits
TEDS Reads information from TEDS-installed sensors.
EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581
Optional Accessories 8-channel input cable U-38 to U-48
Note If the transducer with a remote-sensing function, a 4-conductor extension cable cable (N-81 to N-85) enables measurement. But the remote-sensing function will be ineffective.
Conversion adapter FV-1A

CVM-41A
Strain/Voltage/Acceleration Measurement Card

CVM-41A
  • CE
  • TEDS

Specifications

Applicable Recorders EDX-100A, EDX-200A, and EDX-5000A
Channels 8
Measuring Targets Strain measurement: Strain gages, strain-gage transducers
* For strain measurement, using bridge boxes

Voltage measurement: Voltage

Acceleration measurement (Piezoelectric): Piezoelectric accelerometers (Built-in amplifier)
Input Modes Strain measurement: Balanced differential input

Voltage measurement: Balanced differential input
*When using the Conversion Adapter FV-1A, this becomes unbalanced input
*Common mode input voltage range ±20 VDC, absolute input voltage range ±50 V

Acceleration measurement (Piezoelectric): Unbalanced input
*Conversion Adapter FV-1A usage possible
Input Impedance Voltage Measurement: (1 + 1 MΩ) Within ±10%
*When using the voltage conversation adapter FV-1A (At unbalanced input), within 1 MΩ±10%.
Bridge Excitation or Power Supply to Sensors Strain measurement: Constant voltage output (BV 2V: 2 VDC, BV 5V: 5 VDC, BV 10V: 10 VDC)

Voltage Measurement:Const. voltage output
BV2V: 2 VDC (± 1 V)
BV5V: 5 VDC (± 2.5 V)
BV10V: 10 VDC (± 5 V) or OFF
20 mA/channels or less
Acceleration measurement (Piezoelectric): Constant current output (Approx. 4 mA, Excitation voltage: Approx. 23 VDC, Load: 1 kΩ or less)

*Each channel settable, the max. channels of CVM-41A in EDX-100A is 3 times of units of CVM
Applicable Gage Factor Strain measurement: 2.00 fixed
Applicable Bridge Resistance Strain measurement:
BV2V: 120 to 1000 Ω
BV5V: 350 to 1000 Ω
BV10V: 500 to 1000 Ω
Balance Operation Settings(Zero suppression) Strain measurement:
[Autobalance enabled]
Cancel the unbalanced bridge portion in the analog circuit, and zero the measurement value.
[Autobalance disabled]
Do not cancel the unbalanced bridge portion (The initial unbalanced value in the bridge circuit can beconfirmed)

Voltage Measurement:
[Zero suppression enabled]
Cancel the input voltage in the analog circuit, and zero the measurement value
[Zero suppression disabled]
Do not cancel the input voltage in the analog circuit (Display the input voltage as is)
Balance Adjustment Range Strain measurement:
BV 2V: Resistance ±10% (±50k ×10-6 strain)
BV 5V: Resistance ±4% (±20k ×10-6 strain)
BV 10V: Resistance ±2% (±10k ×10-6 strain)

Voltage Measurement: ±5 V
Measuring Range Strain measurement:
BV2V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k, 500 k ×10-6 strain
BV5V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k ×10-6 strain
BV10V: 2 k, 5 k, 10 k, 20 k, 50 k, 100 k ×10-6 strain

Voltage Measurement:
1, 2, 5, 10, 20, and 50 V

Acceleration measurement (Piezoelectric):
100, 200, 500, 1000, 2000, and 5000 mV
Range Accuracy Strain measurement:
Within ±0.2%FS

Voltage Measurement:
Within ±0.2%FS

Acceleration measurement (Piezoelectric):
Within ±1.0%FS
Nonlinearity Strain measurement:
Within ±0.1%FS

Voltage Measurement:
Within ±0.1%FS

Acceleration measurement (Piezoelectric):
Within ±0.2%FS
Calibration (CAL)SHUNT CAL Strain measurement: ±100% and ±50% of each range and SHUNT
*When SHUNT CAL has 350 Ω load connected, Approx. 257 ×10-6 strain output.

Voltage Measurement: ±100% and ±50% of each range

Acceleration measurement (Piezoelectric): ±100% and ±50% of each range
Frequency Response Strain measurement:
DC coupling: DC to 5 kHz, deviation +1dB, -3dB
AC coupling: 0.2, 1 Hz to 5 kHz (See the HPF.)

Voltage measurement:
DC coupling: DC to 5 kHz, deviation +1dB, -3dB
AC coupling: 0.2, 1 Hz to 5 kHz (See the HPF.)

Acceleration measurement (Piezoelectric):
0.5 Hz to 5 kHz, Deviation +1dB, -3dB
LPF Transfer characteristics : 5 Butterworth type
Cutoff frequencies : 30, 100, 300, 1 k, 3 k Hz, FLAT and AUTO
*With AUTO settings, the cutoff frequency is set to 1/4 of the sampling frequency.
Cutoff accuracy : Within -3±1 dB
Attenuation : (-30±3) dB /oct.
HPF Cutoff frequencies : 0.2, 1 Hz
Attenuation : -6 dB/oct.
Resolution 24 bits
*When installed in EDX-100A, its resolution becomes 16 bits.
Distortion Rate Acceleration measurement (Piezoelectric): 1% or less
Monitor Output Accuracy: Within ±5 V ±0.5% (With ±FS),
Nonlinearity: Within ±0.5%FS
Dimensions 22 W x 119 H x 213 D mm (Excluding protrusions)
Weight Approx. 400 g
TEDS Reads information from TEDS-installed sensors.
EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581
Standard Accessories 2 cross recessed binding head screw M3x6
Optional Accessories CCA input cable U-111
CVM input cable U-121 to U-123
CVM input integrated cable N-121
Integrated output cable U-62
Conversion adapter FV-1A
Voltage input box VI-8A (-T)
Bridge box for quarter bridge system
DBS-120B-8 (C) (T), DBS-350B-8 (C) (T)
One-touch type bridge box DBV-120A-8 (C), DBV-350A-8 (C)

DPM-42B
Dynamic Strain Measurement Card

  • CE
  • TEDS

Specifications

Measuring Targets Strain gages, Strain-gage transducers
Channels 4
Frequency Response DC to 5 kHz (Deviation: ±10%)
Carrier Wave Frequency 12 kHz
Applicable Bridge Resistance 120 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 2 Vrms, 0.5 Vrms switching, 12 kHz sine wave
Balance Adjustment Range Resistance: ±2.4% (±12000 ×10-6 strain)
Capacity: 2000 pF
Balance Adjustment Methods Resistance: Auto balance (Saved in nonvolatile memory)
Capacity: CST method (Capacitance self-tracking)
Measuring Range With bridge excitation 2 Vrms: 200, 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF - 8 steps.
With bridge excitation 0.5 Vrms: 1k, 2k, 5k, 10k, 20k, 50k ×10-6 strain and OFF - 7 steps.
Calibration Values (CAL) Output at ±100% and ±50% of each range
Nonlinearity Within ±0.2% FS
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT, (6 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1 ) dB/oct.
Resolution 16 bits
Check Functions Input resistance into one side of the bridge,and check input
TEDS Reads information from TEDS-installed sensors.
Monitor Output Accuracy: Within ±5 V±0.5% (At ±FS)
Nonlinearity: Within 0.5% FS
Withstand Voltage Between input and output: 250 VAC, 1 min.
EMC Directive EN61326-1 (Class A)
Optional Accessories Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor extension cable (N-81 to N-85) enables measurement. But the remotesensing function will be ineffective.

DPM-42B-F
Dynamic Strain Measurement Card, with Antialiasing LPF

DPM-42B-F
  • CE
  • TEDS

Specifications

Measuring Targets Strain gages, Strain-gage transducers
Channels 4
Frequency Response DC to 5 kHz (Deviation: ±10%)
Carrier Wave Frequency 12 kHz
Applicable Bridge Resistance 120 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 2 Vrms, 0.5 Vrms switching, 12 kHz sine wave
Balance Adjustment Range Resistance: ±2.4% (±12000 ×10-6 strain)
Capacity: 2000 pF
Balance Adjustment Methods Resistance: Auto balance (Saved in nonvolatile memory)
Capacity: CST method (Capacitance self-tracking)
Measuring Range With bridge excitation 2 Vrms: 200, 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF – 8 steps.
With bridge excitation 0.5 Vrms: 1k, 2k, 5k, 10k, 20k, 50k ×10-6 strain and OFF – 7 steps.
Calibration Values (CAL) Output at ±100% and ±50% of each range
Nonlinearity Within ±0.2% FS
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT, (6 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
Antialiasing LPF Transfer characteristics : 8th order Butterworth type
Cutoff frequencies : Automatic setting at x0.25 sampling frequency
Attenuation : -48 ±5 dB (When ×0.5 sampling frequency)
Note: Enabled when "AUTO" set in DCS-100A LPF settings
Resolution 16 bits
Check Functions Input resistance into one side of the bridge,and check input
TEDS Reads information from TEDS-installed sensors.
Monitor Output Accuracy: Within ±5 V±0.5% (At ±FS)
Nonlinearity: Within 0.5% FS
Withstand Voltage Between input and output: 250 VAC, 1 min.
EMC Directive EN61326-1 (Class A)
Optional Accessories Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor
extension cable (N-81 to N-85) enables measurement. But the remotesensing function will be ineffective.

DPM-42B-I
Dynamic Strain Measurement Card, Low Inverter Noise Type

  • CE
  • TEDS

Specifications

Measuring Targets Strain gages, Strain-gage transducers
Channels 4
Frequency Response DC to 5 kHz (Deviation: ±10%)
Carrier Wave Frequency 12 kHz
Applicable Bridge Resistance 120 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 2 Vrms, 0.5 Vrms switching, 12 kHz sine wave
Balance Adjustment Range Resistance: ±2.4% (±12000 ×10-6 strain)
Capacity: 2000 pF
Balance Adjustment Methods Resistance: Auto balance (Saved in nonvolatile memory)
Capacity: CST method (Capacitance self-tracking)
Measuring Range With bridge excitation 2 Vrms: 200, 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF – 8 steps.
With bridge excitation 0.5 Vrms: 1k, 2k, 5k, 10k, 20k, 50k ×10-6 strain and OFF – 7 steps.
Calibration Values (CAL) Output at ±100% and ±50% of each range
Nonlinearity Within ±0.2% FS
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT, (6 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
Resolution 16 bits
Check Functions Input resistance into one side of the bridge,and check input
TEDS Reads information from TEDS-installed sensors.
Monitor Output Accuracy: Within ±5 V±0.5% (At ±FS)
Nonlinearity: Within 0.5% FS
Withstand Voltage Between input and output: 250 VAC, 1 min.
EMC Directive EN61326-1 (Class A)
Optional Accessories Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor extension cable (N-81 to N-85) enables measurement. But the remotesensing function will be ineffective.

DPM-42B-I-F
Dynamic Strain Measurement Card, with Antialiasing LPF, Low Inverter Noise Type

DPM-42B-I-F
  • CE
  • TEDS

Specifications

Measuring Targets Strain gages, Strain-gage transducers
Channels 4
Frequency Response DC to 5 kHz (Deviation: ±10%)
Carrier Wave Frequency 12 kHz
Applicable Bridge Resistance 120 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 2 Vrms, 0.5 Vrms switching, 12 kHz sine wave
Balance Adjustment Range Resistance: ±2.4% (±12000 ×10-6 strain)
Capacity: 2000 pF
Balance Adjustment Methods Resistance: Auto balance (Saved in nonvolatile memory)
Capacity: CST method (Capacitance self-tracking)
Measuring Range With bridge excitation 2 Vrms: 200, 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF – 8 steps.
With bridge excitation 0.5 Vrms: 1k, 2k, 5k, 10k, 20k, 50k ×10-6 strain and OFF – 7 steps.
Calibration Values (CAL) Output at ±100% and ±50% of each range
Nonlinearity Within ±0.2% FS
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 k Hz and FLAT, (6 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1 ) dB/oct.
Antialiasing LPF Transfer Characteristic : 8th order Butterworth type
Cutoff frequencies : Automatic setting at x0.25 sampling frequency
Attenuation : -48 ±5 dB (When ×0.5 sampling frequency)
Notes: Enabled when "AUTO" set in DCS-100A LPF settings
Resolution 16 bits
Check Functions Input resistance into one side of the bridge,and check input
TEDS Reads information from TEDS-installed sensors.
Monitor Output Accuracy: Within ±5 V±0.5% (At ±FS)
Nonlinearity: Within 0.5% FS
Withstand Voltage Between input and output: 250 VAC, 1 min.
EMC Directive EN61326-1 (Class A)
Optional Accessories Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor extension cable (N-81 to N-85) enables measurement. But the remotesensing function will be ineffective.

CTA-40A
Thermocouple Card

  • CE

Specifications

Measuring Targets Thermocouples
Channels 8
Thermocouple Resistance 200 Ω or less (Burnout ON)
1000 Ω or less (Burnout OFF)
Measuring Range K1230, K480, K240, T400, T210 and OFF – 6 steps
K1230 (-200 to 1230ºC)
K480 (-200 to 480ºC)
K240 (-200 to 240ºC)
T400 (-200 to 400ºC)
T210 (-200 to 210ºC)
General Accuracy Within ±(0.5% of reading+1)°C (At ambient temp. 20±3°C)
Within ±(0.5% of reading+2)°C (At ambient temp. 0 to
40°C)
Calibration (CAL) Output at 100% and 50% and 0ºC as absolute value of each range
Frequency Response DC to 10 Hz
Resolution 16 bits
Burnout Built-in: At burnout [Burnout display], with ON/OFF
Note: If high thermocouple resistance, turn the burnout function OFF to improve accuracy.
Monitor Output Accuracy: Within ±5 V±0.5% (At + FS)
Nonlinearity: Within ±0.5%FS
Isolation Between input and output, and between channels: 50 MΩ or more (500 VDC)
EMC Directive EN61326-1 (Class A)
Standard Accessories 8-channel input cable U-104
Temperature measuring adapter CT-2A x8
Optional Accessories Integrated output cable U-62

CFV-40A
F/V Converter Card

  • CE

Specifications

Measuring Targets Alternating signal output sensors
Channels 4
Input Signals AC (Zero cross),
TTL level (Including open collector signals)
Input Voltage ± (0.5 V to 50 V): High hysteresis
± (0.1 V to 50 V): Low hysteresis
Measuring Range 50, 100, 500, 1 k, 2 k, 5 k, 10 k, 20 kHz and OFF - 9 steps
Accuracy: Within ±0.1%FS
Calibration (CAL) Output at 100%, 50% (added), and 0% (Absolute value) of each range
Response Time 10 μs (Continuous pules input ) or less
( 2 cycles of input pules + 50 μs) or less
(Input pules are broken)
Resolution 16 bits
Sensor Power supply 12 VDC: Within ±10% (Each channel 50 mA or less)
Monitor Output Accuracy: Within 5 V±0.5% (At + FS)
Nonlinearity: Within ±0.1%FS
Isolation Between input and output, and between channels: 50 MΩ or more (500 VDC)
Standard Accessories Conversion adapter FV-1A x4
Optional Accessories Input cable U-12, U-13
Monitor output cable U-64

CCA-40A
Charge Amplifier Card

  • CE
  • TEDS

Specifications

Measuring Targets Piezoelectric accelerometers
Applied Accelerometers Built-in amplifier (Voltage output) type
Channels 8
Power Supply to Sensors Constant current power (Current: 4 mA, excitation voltage: Approx. 24 VDC, load 1 kΩ or less)
Frequency Response 1 to 20 kHz (Deviation: + 1 dB, -3 dB)
Measuring Range 20, 50, 100, 200, 500, 1000, 2000, 5000 mV and OFF-9 steps.
Accuracy: Within ±1%FS
Calibration DC CAL: ±100% and ±50% of each range, Accuracy: Within ±0.2%FS
AC CAL: 100% and 50% of each range, Accuracy: Within ±1%FS
Frequency accuracy: Within 100 Hz±5%
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 300, 1 k, 3 k, 10 k, and FLAT (5 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
Distortion Factor 1% or less
Resolution 16 bits
Monitor Output Accuracy: Within 5 V±1% (At +FS)
TEDS Reads information from TEDS-installed sensors.
EMC Directive EN61326-1 (Class A)
Standard Accessories Input cable U-111
Optional Accessories Integrated output cable U-62
Input cable U-109
Conversion adapter (BNC-miniature) BNCP-C25J-A
Conversion adapter (Miniature-Tajimi) CCA-1B
Conversion adapter (BNC-Tajimi) CCA-2B

CCA-40A-F
Charge Amplifier Card, with Antialiasing LPF

CCA-40A-F
  • CE
  • TEDS

Specifications

Measuring Targets Piezoelectric accelerometers
Applied Accelerometers Built-in amplifier (Voltage output) type
Channels 8
Power Supply to Sensors Constant current power (Current: 4 mA, excitation voltage: Approx. 24 VDC, load 1 kΩ or less)
Frequency Response 1 to 20 kHz (Deviation: + 1 dB, -3 dB)
Measuring Range 20, 50, 100, 200, 500, 1000, 2000, 5000 mV and OFF- 9 steps
Accuracy: Within ±1%FS
Calibration DC CAL: ±100% and ±50% of each range, Accuracy: Within ±0.2%FS
AC CAL: 100% and 50% of each range, Accuracy: Within ±1%FS
Frequency accuracy: Within 100 Hz±5%
LPF Transfer characteristics : 2nd order Butterworth
Cutoff frequencies : 300, 1 k, 3 k, 10 k Hz, and FLAT (5 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12±1) dB/oct.
Antialiasing LPF Transfer characteristic : 8th order Butterworth type
Cutoff frequencies : Automatic setting at x0.25 sampling frequency
Attenuation : -48±5dB (When ×0.5 sampling frequency)
Note: Available when the LPF is set to AUTO.
Distortion Factor 1% or less
Resolution 16 bits
Monitor Output Accuracy: Within ±5 V±1% (At +FS)
TEDS Reads information from TEDS-installed sensors.
EMC Directive EN61326-1 (Class A)
Standard Accessories Input cable U-111
Optional Accessories Integrated output cable U-62
Input cable U-109
Conversion adapter (BNC-miniature) BNCP-C25J-A
Conversion adapter (Miniature-Tajimi) CCA-1B
Conversion adapter (BNC-Tajimi) CCA-2B

CAN-41A
CAN Card

CAN-41A
  • CE

Specifications

CAN Board Numbers 2 (2 nodes)
Connector Configuration D-sub 9 pin (male)
Supported CAN Version Bosch2.0B active support (ISO-11898 specifications-compliant)
High-speed CAN/low-speed CAN switching
Measurement ID Numbers Max. 32
CAN Controller Operation Clock 40 MHz, 32 MHz
Baud Rate With high-speed CAN: 1000, 800, 500, 250, 125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 kbps.
With low-speed CAN: 125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 kbps
Communication Conditions Sample points, sampling frequency,resynchronization jump width selection.
Measuring Channel Conditions Start bit, bit length, data type, calibration coefficient
(Conditions for conversion of extracting CAN data to physical quantity)
Graph Display Simultaneous display of graph, numerical value, frame, and analog data
Others Only one card is mounted in the last slot of the EDX.
When measuring CAN data, the sampling frequency is restricted.
EDX-200A: 2048 Hz
EDX-100A: 1 kHz
EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581
Standard Accessories Integrated output cable U-62

CDA-44AS
Constant Current Amplifier Card, Applicable Bridge Resistance 120 Ω

  • TEDS

Specifications

Measuring Targets Strain gages (Full bridge system)
Strain-gage transducers, voltage
Channels 4
Input Resistance Approx. 10 + 10 MΩ (Strain mode)
Approx. 1 MΩ (Voltage mode)
Input Format Balanced differential input (Strain mode)
Unbalanced input (Voltage mode)
IMRR 120 dB (When 500 ×10-6 strain range)
Frequency Response DC coupling: DC to 200 Hz,
deviation: +1 dB, -3 dB
DC cut (AC coupling): 0.2 Hz (See the HPF)
Gage Factor 2.00 fixed (Strain mode)
Bridge Excitation Approx. DC 16.7 mA (Constant current) when gage resistance 120 Ω connected
*If sensitivity or temperature resistance is in the transducer bridge exitation line, then sensitivity and temperature characteristics are not corrected
Cable Length 500 m (At cross section: 0.5 mm 2)
Range Accuracy Within ±0.3% FS
Measuring Range 500, 1 k, 2 k, 5 k, 10 k, 20 k ×10-6 strain, OFF (Strain mode)
1, 2, 5, 10, 20, 50 V, OFF (Voltage mode)
Balance Adjustment Within ±2.4% (±12000 ×10-6 strain) (At strain measurement).
Within ±5 V (At voltage measurement)
ZERO Accuracy Within ±0.3% FS (Voltage OFF mode)
Nonlinearity Within ±0.1% FS
Calibration (CAL) Output at ±100% and ±50% of each range.
Accuracy: Within ±0.3%FS
Monitor Output Accuracy: Within ±5 V±0.5%
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 1, 3, 10, 30, 100 Hz and FLAT, (6 steps)
Amplitude ratio at cutoff point : Within -3±1 dB
Attenuation : whitin (-12±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz
Attenuation : Within (-6±1) dB/oct.
A/D Converter 16 bits
TEDS Reads information from TEDS-installed sensors.
Isolation Between input and case (output), and between
Between channels: Withstand voltage 500 VDC,1 min.
Standard Accessories Conversion adapter FV-2A × 4
Optional Accessories Input cable U-03
Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor extension cable (N-81 to N-85) enables measurement.
But the remote-sensing function will be ineffective.

CDA-45AS
Constant Current Amplifier Card, Applicable Bridge Resistance 350 Ω

CDA-45AS
  • TEDS

Specifications

Measuring Targets Strain gages (Full bridge system)
Strain-gage transducers, voltage
Channels 4
Input Resistance Approx. 10 + 10 MΩ (Strain mode)
Approx. 1 MΩ (Voltage mode)
Input Format Balanced differential input (Strain mode)
Unbalanced input (Voltage mode)
IMRR 120 dB (When 500 ×10-6 strain range)
Frequency Response DC coupling: DC to 200 Hz,
deviation: +1 dB, -3 dB
DC cut (AC coupling): 0.2 Hz (See the HPF)
Gage Factor 2.00 fixed (Strain mode)
Bridge Excitation Approx. DC 5.7 mA (Constant current) when gage resistance 350 Ω connected
*If sensitivity or temperature resistance is in the transducer bridge excitation lines, then sensitivity and temperature characteristics are not corrected.
Cable Length Within 1 km(At cross section: 0.5 mm2)
Range Accuracy Within ±0.3% FS
Measuring Range 500, 1 k, 2 k, 5 k, 10 k, 20 k ×10-6 strain, OFF (Strain mode)
1, 2, 5, 10, 20, 50 V, OFF (Voltage mode)
Balance Adjustment Within ±2.4% (±12000 ×10-6 strain) (At strain measurement).
Within ±5 V (At voltage measurement)
ZERO Accuracy Within ±0.3% FS (Voltage OFF mode)
Nonlinearity Within ±0.1% FS
Calibration (CAL) Output at ±100% and ±50% of each range.
Accuracy: Within ±0.3%FS
Monitor Output Accuracy: Within ±5 V ±0.5%
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 1, 3, 10, 30, 100 and FLAT, (6 steps)
Amplitude ratio at cutoff point : Within -3±1 dB
Attenuation : whitin (-12±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz
Attenuation : Within (-6±1) dB/oct.
A/D Converter 16 bits
TEDS Reads information from TEDS-installed sensors.
Isolation Between input and case (output), and between
Between channels: Withstand voltage 500 VDC,1 min.
Standard Accessories Conversion adapter FV-2A × 4
Optional Accessories Input cable U-03
Monitor output cable U-64
Note If the transducer with a remote-sensing function, a 4-conductor extension cable (N-81 to N-85) enables measurement.
But the remote-sensing function will be ineffective.

CDV-44AS
Strain/Voltage Measurement Insulation Card

  • TEDS

Specifications

Measuring Targets Strain gages (Full bridge system)
Strain-gage transducers, voltage
Channels 4
Input Resistance Strain Measurement: Approx. 10 + 10 MΩ.
Voltage Measurement: Approx. 1 MΩ
Input Format Balanced differential input (Strain mode)
Unbalanced input (Voltage mode)
IMRR 120 dB (When 500 ×10-6 strain range)
Gage Factor 2.00 fixed (Strain mode)
Frequency Response With DC coupling DC to 5 kHz,
deviation within +1 dB, -3 dB
DC cut (With AC coupling) 0.2 Hz
(See the HPF)
Bridge Excitation Within 2 VDC±2% (Strain mode)
Range Accuracy Within ±0.3% FS
Applicable Bridge Resistance 120 to 1000 Ω (Strain mode)
Measuring Range Strain Measurement: 500, 1 k, 2 k, 5 k, 10 k, 20 k ×10-6 strain, OFF
Voltage Measurement: 1, 2, 5, 10, 20, 50 V, OFF
Accuracy: Each range ±0.3%FS
Balance Adjustment Range Within ±2.4% (±12000 ×10-6 strain)
(At strain measurement)
Within ±5 V (At voltage measurement)
ZERO Accuracy Within ±0.3% FS (Voltage OFF mode)
Nonlinearity Within ±0.1% FS
Calibration Values (CAL) Output at ±100% and ±50%of each range
Accuracy: Within ±0.3%FS
Monitor Output Accuracy: Within ±5 V±0.5% (±5 V of full scale of each range)
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 k, Hz and FLAT (6 steps)
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-12±1) dB/oct.
HPF Cutoff frequencies : 0.2Hz
Attenuation : Within (-6±1) dB/oct.
A/D Converter 16 bits
TEDS Reads information from TEDS-installed sensors.
Isolation Between input and case (Output) : Withstand voltage 500 VDC, 1 min.
Between channels : Withstand voltage 500 VDC, 1 min.
Standard Accessories Conversion adapter FV-2A × 4
Optional Accessories Input cable U-03
Monitor output cable U-64 (2 m)
Note If the transducer with a remote-sensing function, a 4-conductor
extension cable (N-81 to N-85) enables measurement.
But the remotesensing function will be ineffective.

CDV-46AS
Strain/Voltage Measurement Isolation Card

CDV-46AS
  • TEDS

Specifications

Measuring Targets Strain gages (Full-bridge system)
Strain-gage transducers, voltage
Channels 4
Input Format Balanced differential input (Strain mode)
Unbalanced input (Voltage mode)
Input Resistance Approx. 10 + 10 MΩ (Strain mode)
Approx. 1 MΩ (Voltage mode)
IMRR 120 dB (When 2k ×10-6 strain range)
Frequency Response With DC coupling DC to 5 kHz,
deviation within +1 dB, -3 dB
DC cut (With AC coupling) 0.2 Hz
(See the HPF)
Gage Factor 2.00 fixed (Strain mode)
Bridge Excitation Within 2 VDC±2% (Strain mode)
Applicable Bridge Resistance 120 to 1000 Ω (Strain mode)
Measurement Range 2k, 5k, 10k, 20k, 50k, 100k ×10-6 strain, OFF
(At strain measurement)
1, 2, 5, 10, 20, 50, OFF (At voltage measurement)
Range Accuracy Within ±0.3%FS
Balance Adjustment Range Within ±2.4% (±12000 ×10-6 strain)
(At strain measurement)
Within ±5 V (At voltage measurement)
ZERO Accuracy Within ±0.3% FS (Voltage OFF mode)
Nonlinearity Within ±0.1%FS
Calibration Values (CAL) Output at ±100% and ±50% of each range
Accuracy: Within ±0.3%FS
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 k, Hz and FLAT (6 steps)
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-12±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz
Attenuation : Within (-6±1) dB/oct.
A/D Converter 24 bits
Monitor Output Accuracy: Within ±5 V±0.5% (±5 V of full scale of each range)
Isolation Between input and case (Output) : Withstand voltage 500 VDC, 1 min.
Between channels : Withstand voltage 500 VDC, 1 min.
TEDS Reads information from TEDS-installed sensors.
Max. Sampling Frequency 100 kHz
Standard Accessories Conversion adapter FV-2A × 4

AD-40AS
A/D Converter Card

Specifications

Channels 8
Input Range ±5 V, ±10 V and OFF
Input Modes Unbalanced (Not balanced differential)
Input Resistance Approx. 1 MΩ
A/D Converter Methods Successive approximation
A/D Converter Resolution: 16 bits (± 32000 counts/FS)
Accuracy Within ±0.2% FS
Nonlinearity Within ±0.1% FS
Input Frequencies Range: DC to 50 kHz
Deviation: 1dB to -3dB
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 k, 3 k, 10 kHz and FLAT (8 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12 ±1) dB/oct.
Power Supply to Sensors ±2.5 V ± 1%, each channel
TEDS Reads information from TEDS-installed sensors.
Optional Accessories 8-channel input cable: U-127 (1.5 m)
Voltage input box: VI-8A with a cable N-121 (1.5 m)

AD-40AS-F
A/D Converter Card, with Antialiasing LPF

Specifications

Channels 8
Input Range ±5 V, ±10 V and OFF
Input Modes Unbalanced (Not balanced differential)
Input Resistance Approx. 1 MΩ
A/D Converter Methods Successive approximation
A/D Converter Resolution: 16 bits (± 32000 counts/FS)
Accuracy Within ±0.2% FS
Nonlinearity Within ±0.1% FS
Input Frequencies Range: DC to 50 kHz
Deviation: 1dB to -3dB
LPF Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 k, 3 k, 10 k Hz and FLAT (8 steps)
Amplitude ratio at cutoff point : -3±1 dB
Attenuation : (-12 ±1) dB/oct.
Antialiasing LPF Transfer characteristics : 8th order Butterworth
Cutoff frequencies : A quarter of sampling frequency (auto setting) *
Attenuation : -48 ± 5 dB*(Set LPF to [AUTO])
Power Supply to Sensors ±2.5 V ± 1%, each channel
TEDS Reads information from TEDS-installed sensors.
Optional Accessories 8-channel input cable: U-127 (1.5 m)
Voltage input box: VI-8A with a cable N-121 (1.5 m)

Page Top

Download