Firmware for EDX-5000A Ver.01.13 (01/21/2019)

Upgraded program for the EDX-5000A firmware

Ver.01.13 (01/21/2019)

CPU board, FPGA file, MSYF-55A

  1. Changed the sampling clock to be output continuously from the [CONT OUT].
  2. Fixed the following bug.
    When the trigger conditions were satisfied just before start recording data (within 4 sampling frequencies) during the "External trigger", the firmware hung.
  3. Fixed the following bug.
    When executed the synchronous operation during the "Manual trigger", the number of recorded data of the master unit and the number of slave units were not identical.

Control Software

Fixed the following bug.

  • When executed the balance adjustment during the synchronous operation, the slave files were overwritten.
  • Example:

    Start monitoring data. Starts monitoring data with the file No. 1.(Data file name: TEST0001_1.KS2)

    Start recording data. Saves the data in the TEST0001_1.KS2.

    Stop recording data. The file No. becomes file No. 2 and the data file name becomes TEST0002_1.KS2 .

    Execute balance adjustment. Error occurs. The file No. becomes file No. 1 and the data file name becomesTEST0001_1.KS2.

    Start recording data. Overwrites the data in the TEST0001_1.KS2.

    • Fixed the following bug.
      When the "Mode of recording" was "External Trigger" and the frequency of the trigger signal voltages (entered to the TRG. IN) fluctuated near that of the sampling frequency, the PC hung immediately after start recording data.
    • Fixed the following bug. Slave units measured the GPS data.
    • ETA-55A: Added the clear function for character strings of scales and numerical values.
    • ETA-55A: Added the swipe function to drop-down lists.
    • ETA-55A: Changed the part of recording conditions not to be set on the slave units.
    • Fixed the following bug.
      ETA-55A: When the master unit started recording data while displaying the data confirmation window of the slave units, the monitoring window did not appear on the ETA-55A. (This bug is the problem of displaying data. Note that the units record data correctly.)
    • ELA-55A: Added the static measurements.
    • ELA-55A: Added the "Set Continuous No. of the CH Name" function on the [Set Continuous No. of the CH Name] window. (Pop-up menu → [Set Continuous No. of the CH Name] menu → [Set Continuous No. of the CH Name] window.
    • ELA-55A: Although the arithmetic expressions did not include an analog channel, the “Calculation ON” appeared on the [Set CH Condition] window. (The bug occurred in the Ver.01.12 only.)
    • Fixed the following bug.
      When connected the external display, the main-display resolution changed.

    Client License Agreement

    The customer and Kyowa Electronic Instruments Co., Ltd. (“company”) agree the following concerning the use of the software package (“software”), copyright to which is owned by the company:

    Article 1. (License Agreement)

    The company grants the customer a license to use the software on a single computer.
    The company prohibits the customer from diverting, transferring, selling or leasing the software for any purpose.

    Article 2. (Disclaimer of Warranty)

    The company makes no warranty as to the quality and performance of the software (*). The company may change the software for improvement without notice. Under no circumstances shall the company be liable for the result of using the software by the customer (*).

    (*)
    Including but not limited to shareware, freeware, sample programs, and updates.

    Agree and download212MB