CDA/CDV-900A
Signal Conditioner

  • CE
  • TEDS

CDA-900A/CDV-900A

Summary

· High sensitivity (Up to 10000 times)
· Fast response (DC to 500 kHz)
· Long-distance testing
  (CDA-900A can measure up to 2 km)
· Excellent nonlinearity (Within ±0.01%FS)
· Universal power supply
  (100 to 240 VAC or 10.5 to 15 VDC)

Features

The CDA/CDV-900A is a Signal Conditioner which features wide frequency response range from DC to 500 kHz, and excellent nonlinearity within ±0.01%FS.
Simple setting enables improvement of work efficiency greatly.

Products table

All display

CDA-900A
Signal Conditioner

  • TEDS

Specifications

Excitation Modes Constant current
Measuring Targets Strain gages, strain-gage transducers and voltage
Channels 1
Compatible Bridge Resistance 120, 350 Ω
Gage Factor 2.00 fixed
Bridge Excitation 120 Ω: 8.3, 16.7 mA
350 Ω: 5.7, 14.3, 28.6 mA
Balancing Range (BAL) Within ±2% (± 10000 ×10-6 strain)
Balancing Method Auto balance
Accuracy: ±1 ×10-6 strain
  (At sensitive of 10 V/1000 ×10-6 strain.)
Saved in nonvolatile memory
Nonlinearity Within ±0.01% FS
Input Impedance 10 MΩ +10 MΩ or more
Output Impedance Approx. 2 Ω
Calibration (CAL) Equivalent strain: ±(1 to 9999 ×10-6 strain)
DC voltage: ± (10 to 99990 μV)
Setting: CAL switch (4-digital switch)

Accuracy:
Within ± (0.2% +0.5 ×10-6 strain)
Within ± (0.1% +5.0 μVRTI)
Sensitivity Adjustment Sensitivity is set in combination with CAL and VOLTAGE OUT switches (4-digit digital switches)

CAL switch range: 100 to 9999 ×10-6 strain by 1 ×10-6 strain step
VOLTAGE OUT switch range: 1.00 to 10.00 by 0.01 V step
Accuracy: Within ± (0.5% + 5 mV)
Range: ×200 to ×10000
Fine Sensitivity Adjustment Range: 1 to 1/2.5
Frequency Response DC to 500 kHz
(Amplitude deviation: 1, -3 dB)
LPF Transfer characteristic : 4th order Butterworth
Cutoff frequencies : 10, 100, 1 k, 10 k, 100 k Hz and FLAT - 6 steps
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-24 ±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz, OFF - 2 steps
Output OUTPUT A: ±10 V (Load resistance: 5 kΩ or more)
OUTPUT B: ±10 V (Load resistance: 5 kΩ or more)
Noise LPF FLAT: 40 μVp-p or less
LPF 100 kHz: 16 μVp-p or less
LPF 10 kHz: 6 μVp-p or less
LPF 1 kHz: 4 μVp-p or less
LPF 100 Hz: 3 μVp-p or less
LPF 10 Hz: 2 μVp-p or less

(At Bridge excitation: 2 V, bridge resistance: 120 Ω, 1000 ×10-6 strain input, 10.00 V output set)
Allowable Max. Input Voltage ±15 V
Allowable Common Mode Voltage ±10 V
CMRR 100 dB or more
Stability Temperature
Zero point: ±1 ×10-6 strain per °C
Sensitivity: ±0.01%/°C

Time
Zero point: ±5 ×10-6 strain/24 h
Sensitivity: ±0.05%/24 h

Power supply
Zero point: ±0.05%FS/power fluctuation ±10%
Sensitivity: ±0.05%/power fluctuation ±10%
(At sensitivity of 10 V per 1000 ×10-6 strain)
Withstand Voltage 1 kVAC for 1 min between AC power supply and case
Output Voltage Indication 4½ digit digital display (7-segment LED)
11-segment LED bar meter
Over Input Indication Output voltage display flashing
(4½ digit digital display only)
Check Functions Bridge resistance check
Key Lock Function Locks all keys other than POWER switch.
(Allows settings on digital CAL and VOLTAGE OUT switches to be changed)
Remote Functions Balance adjustment execute (BAL)
Calibration strain output execute (CAL)
Key lock
TEDS Reads the sensor TEDS information, and sets the rated output to the VOLTAGE OUT output voltage.
Actual Load Calibration Sets actual load input to the VOLTAGE OUT output voltage.
User’s Function Bridge-resistance compensation
Extension Cable Length Up to 2 km
*By a 4-conductor (0.5 mm2) shielded cable
Vibration Resistant 5 to 200 Hz, with 29.4 m/s2 (3 G) in X, Y
and Z directions for 12 cycles, 10 min/cycle
Impact Resistant 15 G, 11 ms or less, in X, Y
and Z directions, every 3 cycles
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -30 to 70ºC
Power Supply 100 to 240 VAC, approx. 8 VA (At 100 VAC)
10.5 to 15 VDC, approx. 4 W (At 12 VDC)
Dimensions 49 W x 128.5 H x 262.5 D mm
(Excluding protrusions)
Weight Approx. 1.0 kg
Standard Accessories Output cable U-08, U-59
AC power cable P-25 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Input cable U-37
Extension cables N-81 to N-85
Housing case YC-A
Amplifier stand FA-1B

CDA-900A-DC
Signal Conditioner

  • CE
  • TEDS

Specifications

Excitation Modes Constant current
Measuring Targets Strain gages, strain-gage transducers and voltage
Channels 1
Compatible Bridge Resistance 120, 350 Ω
Gage Factor 2.00 fixed
Bridge Excitation 120 Ω: 8.3, 16.7 mA
350 Ω: 5.7, 14.3, 28.6 mA
Balancing Range (BAL) Within ±2% (± 10000 ×10-6 strain)
Balancing Method Auto balance
Accuracy: ±1 ×10-6 strain
  (At sensitive of 10 V/1000 ×10-6 strain.)
Saved in nonvolatile memory
Nonlinearity Within ±0.01% FS
Input Impedance 10 MΩ +10 MΩ or more
Output Impedance Approx. 2 Ω
Calibration (CAL) Equivalent strain: ±(1 to 9999 ×10-6 strain)
DC voltage: ± (10 to 99990 μV)
Setting: CAL switch (4-digital switch)

Accuracy:
Within ± (0.2% +0.5 ×10-6 strain)
Within ± (0.1% +5.0 μVRTI)
Sensitivity Adjustment Sensitivity is set in combination with CAL and VOLTAGE OUT switches (4-digit digital switches)

CAL switch range: 100 to 9999 ×10-6 strain by 1 ×10-6 strain step
VOLTAGE OUT switch range: 1.00 to 10.00 by 0.01 V step
Accuracy: Within ± (0.5% +5 mV)
Range: ×200 to ×10000
Fine Sensitivity Adjustment Range: 1 to 1/2.5
Frequency Response DC to 500 kHz
(Amplitude deviation: 1, -3 dB)
LPF Transfer characteristic : 4th order Butterworth
Cutoff frequencies : 10, 100, 1 k, 10 k, 100 k Hz and FLAT - 6 steps
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-24 ±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz, OFF - 2 steps
Output OUTPUT A: ±10 V (Load resistance 5 kΩ or more)
OUTPUT B: ±10 V (Load resistance 5 kΩ or more)
Noise LPF FLAT: 40 μVp-p or less
LPF 100 kHz: 16 μVp-p or less
LPF 10 kHz: 6 μVp-p or less
LPF 1 kHz:  4μVp-p or less
LPF 100 Hz: 3 μVp-p or less
LPF 10 Hz: 2 μVp-p or less

(At Bridge excitation: 2 V, bridge resistance: 120 Ω, 1000 ×10-6 strain input, 10.00 V output set)
Allowable Max. Input Voltage ±15 V
Allowable Common Mode Voltage ±10 V
CMRR 100 dB or more
Stability Temperature
Zero point: ±1 ×10-6 strain per °C
Sensitivity: ±0.01%/°C

Time
Zero point: ±5 ×10-6 strain/24 h
Sensitivity: ±0.05%/24 h

Power supply
Zero point: ±0.05%FS/power fluctuation ±10%
Sensitivity: ±0.05%/power fluctuation ±10%
(At sensitivity of 10 V per 1000 ×10-6 strain)
Output Voltage Indication 4½ digit digital display (7-segment LED)
11-segment LED bar meter
Over Input Indication Output voltage display flashing
(4½ digit digital display only)
Check Functions Bridge resistance check
Key Lock Function Locks all keys other than POWER switch.
(Allows settings on digital CAL and VOLTAGE OUT switches to be changed)
Remote Functions Balance adjustment execute (BAL)
Calibration strain output execute (CAL)
Key lock
TEDS Reads the sensor TEDS information, and sets the rated output to the VOLTAGE OUT output voltage.
Actual Load Calibration Sets actual load input to the VOLTAGE OUT output voltage.
User’s Function Bridge-resistance compensation
Extension Cable Length Up to 2 km
*By a 4-conductor (0.5 mm2) shielded cable
Vibration Resistant 5 to 200 Hz, with 29.4 m/s2 (3 G) in X, Y
and Z directions for 12 cycles, 10 min/cycle
Impact Resistant 15 G, 11 ms or less, in X, Y
and Z directions, every 3 cycles
Operating Temperature -10 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -30 to 70ºC
Power Supply 10.5 to 15 VDC, approx. 4 W (At 12 VDC)
Dimensions 49 W x 128.5 H x 262.5 D mm
(Excluding protrusions)
Weight Approx. 1.0 kg
Compliance Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)
Standard Accessories Output cable U-08, U-59
DC power cable P-69
Ferrite core × 5
Instruction manual
Optional Accessories Input cable U-37
Extension cables N-81 to N-85
Housing case YC-A
Amplifier stand FA-1B
AC adapter SA-10A-AMP

CDV-900A
Signal Conditioner

  • TEDS

Specifications

Excitation Modes Constant voltage
Remote Sensing Auto (On/off automatically)
Manual (On constantly)
Measuring Targets Strain gages, strain-gage transducers and voltage
Channels 1
Compatible Bridge Resistance 60 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 1, 2, 5, 10 V
Balancing Range (BAL) Within ±2% (± 10000 ×10-6 strain)
Balancing Method Auto balance
Accuracy: ±1 ×10-6 strain
  (At sensitive of 10 V/1000 ×10-6 strain.)
Saved in nonvolatile memory
Nonlinearity Within ±0.01% FS
Input Impedance 10 MΩ + 10 MΩ or more
Output Impedance Approx. 2 Ω
Calibration (CAL) Equivalent strain: ±(1 to 9999 ×10-6 strain)
DC voltage: ±(10 to 99990 μV)
Setting: CAL switch (4-digital switch)

Accuracy:
Within ± (0.2% +0.5 ×10-6 strain)
Within ± (0.1% +5.0 μVRTI)
Sensitivity Adjustment Sensitivity is set in combination with CAL and VOLTAGE OUT switches (4-digit digital switches)

CAL switch range: 100 to 9999 ×10-6 strain by 1 ×10-6 strain step
VOLTAGE OUT switch range: 1.00 to 10.00 by 0.01 V step
Accuracy: Within ± (0.5% +5 mV)
Range: ×200 to ×10000
Fine Sensitivity Adjustment Range: 1 to 1/2.5
Frequency Response DC to 500 kHz
(Amplitude deviation: 1, -3 dB)
LPF Transfer characteristic : 4th order Butterworth
Cutoff frequencies : 10, 100, 1 k, 10 k, 100 k Hz and FLAT - 6 steps
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-24 ±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz , OFF - 2 steps
Output OUTPUT A: ±10 V (Load resistance 5 kΩ or more)
OUTPUT B: ±10 V (Load resistance 5 kΩ or more)
Noise LPF FLAT: 40 μVp-p or less
LPF 100 kHz: 16 μVp-p or less
LPF 10 kHz: 6 μVp-p or less
LPF 1 kHz: 4 μVp-p or less
LPF 100 Hz: 3 μVp-p or less
LPF 10 Hz: 2 μVp-p or less

(At Bridge excitation: 2 V, bridge resistance: 120 Ω, 1000 ×10-6 strain input, 10.00 V output set)
Allowable Max. Input Voltage ±15 V
Allowable Common Mode Voltage ±10 V
CMRR 100 dB or more
Stability Temperature
Zero point: ±1 ×10-6 strain per °C
Sensitivity: ±0.01%/°C

Time
Zero point: ±5 ×10-6 strain/24 h
Sensitivity: ±0.05%/24 h

Power supply
Zero point: ±0.05%FS/power fluctuation ±10%
Sensitivity: ±0.05%/power fluctuation ±10%
(At sensitivity of 10 V per 1000 ×10-6 strain)
Withstand Voltage 1 kVAC for 1 min between AC power supply and case
Output Voltage Indication 4½ digit digital display (7-segment LED)
11-segment LED bar meter
Over Input Indication Output voltage display flashing
(4½ digit digital display only)
Check Functions Bridge resistance check
Key Lock Function Locks all keys other than POWER switch.
(Allows settings on digital CAL and VOLTAGE OUT switches to be changed)
Remote Functions Balance adjustment execute (BAL)
Calibration strain output execute (CAL)
Key lock
TEDS Reads the sensor TEDS information, and sets the rated output to the VOLTAGE OUT output voltage.
Actual Load Calibration Sets actual load input to the VOLTAGE OUT output voltage.
User’s Function Cable-resistance compensation
Extension Cable Length Up to 2 km (Using a sensing cable)
*By a 6-conductor (0.5 mm2) shielded cable
Vibration Resistant 5 to 200 Hz, with 29.4 m/s2 (3 G) in X, Y
and Z directions for 12 cycles, 10 min/cycle
Impact Resistant 15 G, 11 ms or less, in X, Y
and Z directions, every 3 cycles
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -30 to 70ºC
Power Supply 100 to 240 VAC, approx. 8 VA (At 100 VAC)
10.5 to 15 VDC, approx. 4W (At 12 VDC)
Dimensions 49 W × 128.5 H × 262.5 D mm
(Excluding protrusions)
Weight Approx. 1.0 kg
Standard Accessories Output cable U-08, U-59
AC power cable P-25 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Input cable U-37
Extension cables N-81 to N-85
Housing case YC-A
Amplifier stand FA-1B

Dimensions

CDV-900A

CDV-900A-DC
Signal Conditioner

  • CE
  • TEDS

Specifications

Excitation Modes Constant voltage
Remote Sensing Auto (On/off automatically)
Manual (On constantly)
Measuring Targets Strain gages, strain-gage transducers and voltage
Channels 1
Compatible Bridge Resistance 60 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 1, 2, 5, 10 V
Balancing Range (BAL) Within ±2% (± 10000 ×10-6 strain)
Balancing Method Auto balance
Accuracy: ±1 ×10-6 strain
  (At sensitive of 10 V/1000 ×10-6 strain.)
Saved in nonvolatile memory
Nonlinearity Within ±0.01% FS
Input Impedance 10 MΩ + 10 MΩ or more
Output Impedance Approx. 2 Ω
Calibration (CAL) Equivalent strain: ±(1 to 9999 ×10-6 strain)
DC voltage: ± (10 to 99990 μV)
Setting: CAL switch (4-digital switch)

Accuracy:
Within ± (0.2% +0.5 ×10-6 strain)
Within ± (0.1% +5.0 μVRTI)
Sensitivity Adjustment Sensitivity is set in combination with CAL and VOLTAGE OUT switches (4-digit digital switches)

CAL switch range: 100 to 9999 ×10-6 strain by 1 ×10-6 strain step
VOLTAGE OUT switch range: 1.00 to 10.00 by 0.01 V step
Accuracy: Within ± (0.5% + 5 mV)
Range: ×200 to ×10000
Fine Sensitivity Adjustment Range: 1 to 1/2.5
Frequency Response DC to 500 kHz
(Amplitude deviation: 1, -3 dB)
LPF Transfer characteristic : 4th order Butterworth
Cutoff frequencies : 10, 100, 1 k, 10 k, 100 k Hz and FLAT - 6 steps
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-24 ±1) dB/oct.
HPF Cutoff frequencies : 0.2 Hz, OFF - 2 steps
Output OUTPUT A: ±10 V (Load resistance 5 kΩ or more)
OUTPUT B: ±10 V (Load resistance 5 kΩ or more)
Noise LPF FLAT: 40 μVp-p or less
LPF 100 kHz: 16 μVp-p or less
LPF 10 kHz: 6 μVp-p or less
LPF 1 kHz: 4 μVp-p or less
LPF 100 Hz: 3 μVp-p or less
LPF 10 Hz: 2 μVp-p or less

(At Bridge excitation: 2 V, bridge resistance: 120 Ω, 1000 ×10-6 strain input, 10.00 V output set)
Allowable Max. Input Voltage ±15 V
Allowable Common Mode Voltage ±10 V
CMRR 100 dB or more
Stability Temperature
Zero point: ±1 ×10-6 strain per °C
Sensitivity: ±0.01%/°C

Time
Zero point: ±5 ×10-6 strain/24 h
Sensitivity: ±0.05%/24 h

Power supply
Zero point: ±0.05%FS/power fluctuation ±10%
Sensitivity: ±0.05%/power fluctuation ±10%
(At sensitivity of 10 V per 1000 ×10-6 strain)
Output Voltage Indication 4½ digit digital display (7-segment LED)
11-segment LED bar meter
Over Input Indication Output voltage display flashing
(4½ digit digital display only)
Check Functions Bridge resistance check
Key Lock Function Locks all keys other than POWER switch.
(Allows settings on digital CAL and VOLTAGE OUT switches to be changed)
Remote Functions Balance adjustment execute (BAL)
Calibration strain output execute (CAL)
Key lock
TEDS Reads the sensor TEDS information, and sets the rated output to the VOLTAGE OUT output voltage.
Actual Load Calibration Sets actual load input to the VOLTAGE OUT output voltage.
User’s Function Cable-resistance compensation
Extension Cable Length Up to 2 km (Using a sensing cable)
*By a 6-conductor (0.5 mm2) shielded cable
Vibration Resistant 5 to 200 Hz, with 29.4 m/s2 (3 G) in X, Y
and Z directions for 12 cycles, 10 min/cycle
Impact Resistant 15 G, 11 ms or less, in X, Y
and Z directions, every 3 cycles
Operating Temperature -10 to 50°C
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -30 to 70ºC
Power Supply 10.5 to 15 VDC, approx. 4 W (At 12 VDC)
Dimensions 49 W x 128.5 H x 262.5 D mm
(Excluding protrusions)
Weight Approx. 1.0 kg
Compliance Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)
Standard Accessories Output cable U-08, U-59
DC power cable P-69
Ferrite core × 5
Instruction manual
Optional Accessories Input cable U-37
Extension cables N-81 to N-85
Housing case YC-A
Amplifier stand FA-1B
AC adapter SA-10A-AMP

Dimensions

CDV-900A

Housing Cases

YC-3A
Portable Housing Case (3 housing units)

Model YC-3A
YC-3A-AC/DC
Object Product Model DPM-900 series
CDV-900A
CDA-900A
VAQ-700A
DA-710A
Housing Units 3
Power Supply 100 VAC (YC-3A)
100 VAC or 12 VDC (YC-3A-AC/DC)
Standard Accessories AC power cable P-17 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Dummy panel for 1 channel: YB-DUMMY
Handle for YC-A: YC-HANDLE

Dimensions

YC-A

YC-4A
Portable Housing Case (4 housing units)

YC-4A
Model YC-4A
YC-4A-AC/DC
Object Product Model DPM-900 series
CDV-900A
CDA-900A
VAQ-700A
DA-710A
Housing Units 4
Power Supply 100 VAC (YC-4A)
100 VAC or 12 VDC (YC-4A-AC/DC)
Standard Accessories AC power cable P-17 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Dummy panel for 1 channel: YB-DUMMY
Handle for YC-A: YC-HANDLE

YC-6A
Portable Housing Case (6 housing units)

YC-6A
Model YC-6A
YC-6A-AC/DC
Object Product Model DPM-900 series
CDV-900A
CDA-900A
VAQ-700A
DA-710A
Housing Units 6
Power Supply 100 VAC (YC-6A)
100 VAC or 12 VDC (YC-6A-AC/DC)
Standard Accessories AC power cable P-17 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Dummy panel for 1 channel: YB-DUMMY
Handle for YC-A: YC-HANDLE

YC-8A
Portable Housing Case (8 housing units)

Model YC-8A
YC-8A-AC/DC
Object Product Model DPM-900 series
CDV-900A
CDA-900A
VAQ-700A
DA-710A
Housing Units 8
Power Supply 100 VAC (YC-8A)
100 VAC or 12 VDC (YC-8A-AC/DC)
Standard Accessories AC power cable P-17 (With 2-pin conversion plug CM-52)
Instruction manual
Optional Accessories Dummy panel for 1 channel: YB-DUMMY
Handle for YC-A: YC-HANDLE

Dimensions

YC-A

SA-10A-AMP
AC adapter

SA-10A-AMP

Specifications

Object Product Model CDV-900A-DC, CDA-900A-DC

FA-1B
Amplifier Stand

Object Product Model DPM-900 series
DA-710A
CDV-900A
CDA-900A
VAQ-700A

Page Top