EDX-100A
Universal Recorder

Summary
· Available with 1, 2 and 4 slots
· LAN port for establishing multichannel network
(Max. 256 channels)
Features
The EDX-100A is a data recorder for measuring up to 256 channels.
Various conditioner cards are available for wide applications.
Products table
All display
EDX-100A-1
1 slot, 8 channels

Specifications
Models | EDX-100A-1 (With DCS-100A) EDX-100A-1-0 EDX-100A-1-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 8 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45× speed or higher) Offline data transfer to computers is enabled after the recording is complete |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 1.2 A (When operated on 12 VDC with 1 CDV-40B card mounted and full load applied) |
Dimensions | 70.0 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 1.6 kg (1.7 kg with 1 CDV-40B card mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
EDX-100A-2
2 slots, 16 channels

Specifications
Models | EDX-100A-2 (With DCS-100A) EDX-100A-2-0 EDX-100A-2-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 16 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45x speed or higher) Up to 2 GB data for 1 time of measurement |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 1.8 A (When operated on 12 VDC with 2 CDV-40B cards mounted and full load applied) |
Dimensions | 92.5 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 1.8 kg (2.0 kg with 2 CDV-40B cards mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
EDX-100A-4
4 slots, 32 channels

Specifications
Models | EDX-100A-4 (With DCS-100A) EDX-100A-4-0 EDX-100A-4-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 32 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45x speed or higher) Up to 2 GB data for 1 time of measurement |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as a trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 2.8 A (When operated on 12 VDC with 4 CDV-40B cards mounted and full load applied) |
Dimensions | 137.5 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 2.0 kg (2.6 kg with 4 CDV-40B card mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
EDX-100A-1H
1 slot, 8 channels, with handle grip

Specifications
Models | EDX-100A-1H (With DCS-100A) EDX-100A-1H-0 EDX-100A-1H-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 8 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45x speed or higher) Up to 2 GB data for 1 time of measurement |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 1.2 A (When operated on 12 VDC with 1 CDV-40B card mounted and full load applied) |
Dimensions | 70.0 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 1.6 kg (1.7 kg with 1 CDV-40B card mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
Dimensions

EDX-100A-2H
2 slots, 16 channels, with handle grip

Specifications
Models | EDX-100A-2H (With DCS-100A) EDX-100A-2H-0 EDX-100A-2H-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 16 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45x speed or higher) Up to 2 GB data for 1 time of measurement |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 1.8 A (When operated on 12 VDC with 2 CDV-40B cards mounted and full load applied) |
Dimensions | 92.5 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 1.8 kg (2.0 kg with 2 CDV-40B card mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
Dimensions

EDX-100A-4H
4 slots, 32 channels, with handle grip

Specifications
Models | EDX-100A-4H (With DCS-100A) EDX-100A-4H-0 EDX-100A-4H-1 (With DCS-100A and DCS-101A) |
---|---|
Max. Channels | 32 |
Analog Input | Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed |
CAN Data Input | Accepts one card of CAN-41A |
Voice Memo Input | 1 channel. Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory) |
Sampling Frequency
Sampling Methods | Synchronous sampling of all channels |
---|---|
Sampling Frequency Series | 1Hz to 100kHz(1-2-5 series): for 1 channel measurement 1Hz to 10kHz(1-2-5 series): for 16 channel measurement 1Hz to 5kHz(1-2-5 series): for 32 channel measurement 1Hz to 1kHz(1-2-5 series): for CAN data measurement |
Data Storage | CF cards recommended by Kyowa (128 MB to 8 GB; 45x speed or higher) Up to 2 GB data for 1 time of measurement |
---|---|
Setting Conditions | Online: From the PC via LAN or USB port Offline: By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software |
Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
Measuring Modes
Manual | Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
---|---|
Trigger | Data recording is automatically started when the preset trigger condition is satisfied. Note that any CAN data mustn't be used as trigger condition |
Interval | Data recording is periodically made at preset intervals. |
Manual Start/Stop of Data Recording | Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
---|---|
Balance Adjustment | Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC. |
Saved Data Format | Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A |
Collecting Data | LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer. |
TEDS | Reads sensor's information and sets to channel condition automatically. [Supported conditioner cards] CDV-40B (-F) DPM-42B (-F) DPM-42B-I (-F) CCA-40A (-F) CDV-44AS CDA-44AS/45AS CVM-41A AD-40AS (-F) |
Synchronous Operation | Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC. |
Analog Output | All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A. Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS). |
CF Card Slot | 1 (For data recording and condition setting) |
Interfaces
LAN and USB (For control and data transfer), switchable | |
LAN I/F | 10BASE-T/100BASE-TX Connector: RJ45 modular jack |
USB I/F | Conforms to USB 2.0 (High speed). Connector: Series B receptacle |
Operation Switches | REC/PAUSE: Starts/pauses data recording. STOP: Stops data recording. BAL.: Executes balance adjustment. READ: Reads and sets conditions. ID: Sets ID No. of EDX-100A. LAN/USB: Switches communication port. |
---|---|
Indicators | Operation status indicator LEDs: 7 Channel status indicator LEDs: The number corresponds to the number of channels provided. |
External Control Connectors | CONT IN and CONT OUT (For remote control and synchronous operation) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Vibration Resistant | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Power Supply | 10 to 18 VDC Connector: RM12BRD-4PH (Hirose) DC power supply or optional dedicated AC adapter is required. |
Current Consumption | Approx. 2.8 A (When operated on 12 VDC with 4 CDV-40B cards mounted and full load applied) |
Dimensions | 137.5 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | 2.0 kg (2.6 kg with 4 CDV-40B card mounted) |
Standard Accessories | DC power cable P-76 Ground wire P-72 USB cable N-38 CF card (1 GB) DVD (Dynamic data acquisition software DCS-100A) *DCS-100A is optional for models with suffix "-0". |
---|---|
Optional Accessories | USB cable N-39 (2 m) Synchronous cable N-128 Camera synchronous cable N-98, N-99, N-101 AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Cable fixture Synchronous extension unit ESYN-30A Remote control unit RCU-41A Battery unit for instantaneous power failure EDB-41B Monitor unit EMON-20A Dummy panel EDX2000-DUMMY |
Dimensions

RCU-41A
Remote Control Unit

Object Product Model | EDX-100A |
---|---|
Control Functions | ①"REC/PAUSE": Starts/pauses data recording. ②"STOP": Stops data recording. ③"BAL": Executes balance adjustment. ④"VOICE MEMO": Records voice memo. |
Indicators | REC/PAUSE, BAL |
Cable Length | Approx. 1.5 m (Used by connecting to the CONT IN connector of the EDX-100A recorder unit) |
Dimensions | 35 W × 110 H × 20 D mm *Excluding protrusions |
Weight | Approx.200 g |
EDB-41B
Battery Unit for Instantaneous Power Failure

Specifications
Applicable EDX | EDX-100A-1(H), EDX-100A-2(H), EDX-100A-4(H), EDX-200A-2H, EDX-200A-4H |
---|---|
Built-in Batteries | Battery type: Nickel-Metal Hydride (Ni-MH) battery Nominal capacity: 730 mAh, nominal voltage: 12 V |
External Power Supply Input | 11 V to 18 VDC [DC IN] connector type: RM12BRD-4PH (HIROSE made) DC power supply, AC adapter (Optional) for EDX-100A, or AC adapter (Optional) for EDX-200A is used |
Power Supply Output | External power voltage when using external power drive Approx. 11 to 15 V when using this units drive (In instantaneous stop) [DC OUT] terminal model: RM12BRD-4S (Hirose) When operated on external power supply: Voltage of the external power supply When operated on the EDB-41B (During instantaneous power failure): Approximately 11 to 15 V [DC OUT] connector type: RM12BRD-4S (HIROSE made) |
Charging Method | Automatically starts charging the battery by connecting the external power supply. (Battery charging period: Max. 3.5 hours) Starts discharging by pressing the [REFRESH] button. (Refresh period: Max. 6.5 hours) |
Indicator | [BATTERY LEVEL] LED (With [CHECK] button turned ON.) Remaining capacity of the built-in battery is 10% or more: Lights up green Remaining capacity of the built-in battery is 10% or less: Lights up red [CHARGE] LED During charging----------ON green During discharging------ON orange Charging complete------OFF |
Buzzer | During instantaneous power supply, alarm buzzer is issued. |
Operating Temperature | 0 to 50°C (However, when charging and refreshing: 0 to 30°C) |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | -20 to 50°C |
Vibration Resistance | ±29.42 m/s2 (3 G), 5 to 55 Hz (When operated) ±49.03 m/s2 (5 G), 5 to 55 Hz (When not operated) |
Impact Resistance | 196.10 m/s2 (20 G), 11 ms. |
Dimensions | 25 W x 132.5 H x 255 D mm (Excluding protrusions) |
Weight | Approx. 500 g |
Backup Time (Reference value) | Approx. 30 minutes When 1 CDV-40B card (8 CHs) is installed to the EDX-100A-1(H) and full loaded Approx. 15 minutes When 2 CDV-40B cards (16 CHs) are installed to the EDX-100A-2(H) and full loaded Approx. 5 minutes When 4 CDV-40B cards (32 CHs) are installed to the EDX-100A-4(H) and full loaded Approx. 15 minutes When 2 CDV-40B cards (16 CHs) are installed to the EDX-200A-2H and full loaded Approx. 5 minutes When 4 CDV-40B cards (32 CHs) are installed to the EDX-200A-4H and full loaded * When built-in battery is fully charged and ambient temperature is 20 to 30°C |
To Ensure Safe Usage
For LAN connection, use straight cables and a hub.