EDX-100A
Universal Recorder

  • TEDS

EDX-100A

Summary

· Available with 1, 2 and 4 slots
· LAN port for establishing multichannel network
 (Max. 256 channels)

Features

The EDX-100A is a data recorder for measuring up to 256 channels.
Various conditioner cards are available for wide applications.

Products table

All display

EDX-100A-1
1 slot, 8 channels

  • TEDS

Specifications

Models EDX-100A-1 (With DCS-100A)
EDX-100A-1-0
EDX-100A-1-1 (With DCS-100A and DCS-101A)
Max. Channels 8
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45× speed or higher)
Offline data transfer to computers is enabled after the recording is complete
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 1.2 A
(When operated on 12 VDC with 1 CDV-40B card mounted and full load applied)
Dimensions 70.0 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 1.6 kg
(1.7 kg with 1 CDV-40B card mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

EDX-100A-2
2 slots, 16 channels

  • TEDS

Specifications

Models EDX-100A-2 (With DCS-100A)
EDX-100A-2-0
EDX-100A-2-1 (With DCS-100A and DCS-101A)
Max. Channels 16
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)

Up to 2 GB data for 1 time of measurement
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 1.8 A
(When operated on 12 VDC with 2 CDV-40B cards mounted and full load applied)
Dimensions 92.5 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 1.8 kg
(2.0 kg with 2 CDV-40B cards mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

EDX-100A-4
4 slots, 32 channels

  • TEDS

Specifications

Models EDX-100A-4 (With DCS-100A)
EDX-100A-4-0
EDX-100A-4-1 (With DCS-100A and DCS-101A)
Max. Channels 32
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)

Up to 2 GB data for 1 time of measurement
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as a trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 2.8 A
(When operated on 12 VDC with 4 CDV-40B cards mounted and full load applied)
Dimensions 137.5 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 2.0 kg
(2.6 kg with 4 CDV-40B card mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

EDX-100A-1H
1 slot, 8 channels, with handle grip

  • TEDS

Specifications

Models EDX-100A-1H (With DCS-100A)
EDX-100A-1H-0
EDX-100A-1H-1 (With DCS-100A and DCS-101A)
Max. Channels 8
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)

Up to 2 GB data for 1 time of measurement
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 1.2 A
(When operated on 12 VDC with 1 CDV-40B card mounted and full load applied)
Dimensions 70.0 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 1.6 kg
(1.7 kg with 1 CDV-40B card mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

Dimensions

EDX-100A

EDX-100A-2H
2 slots, 16 channels, with handle grip

  • TEDS

Specifications

Models EDX-100A-2H (With DCS-100A)
EDX-100A-2H-0
EDX-100A-2H-1 (With DCS-100A and DCS-101A)
Max. Channels 16
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)

Up to 2 GB data for 1 time of measurement
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 1.8 A
(When operated on 12 VDC with 2 CDV-40B cards mounted and full load applied)
Dimensions 92.5 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 1.8 kg
(2.0 kg with 2 CDV-40B card mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

Dimensions

EDX-100A

EDX-100A-4H
4 slots, 32 channels, with handle grip

  • TEDS

Specifications

Models EDX-100A-4H (With DCS-100A)
EDX-100A-4H-0
EDX-100A-4H-1 (With DCS-100A and DCS-101A)
Max. Channels 32
Analog Input Optional conditioner cards

Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Accepts one card of CAN-41A
Voice Memo Input 1 channel.
Record voice memos included with recordings alongside with measurement data (during manual measurements) using a dedicated remote control(optional accessory)
Sampling Frequency
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Series 1Hz to 100kHz(1-2-5 series): for 1 channel measurement
1Hz to 10kHz(1-2-5 series): for 16 channel measurement
1Hz to 5kHz(1-2-5 series): for 32 channel measurement
1Hz to 1kHz(1-2-5 series): for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)

Up to 2 GB data for 1 time of measurement
Setting Conditions Online: From the PC via LAN or USB port

Offline:
By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.

Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.

Note that any CAN data mustn't be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels are balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor's information and sets to channel condition automatically.

[Supported conditioner cards]
 CDV-40B (-F)
 DPM-42B (-F)
 DPM-42B-I (-F)
 CCA-40A (-F)
 CDV-44AS
 CDA-44AS/45AS
 CVM-41A
 AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A.
While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output All, except for CDV-40B (-F), AD-40AS (-F), and CAN-41A.

Conditioner cards provide an analog output connector, enabling voltage monitoring (±5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces
  LAN and USB (For control and data transfer), switchable
LAN I/F 10BASE-T/100BASE-TX
Connector: RJ45 modular jack
USB I/F Conforms to USB 2.0 (High speed).
Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Executes balance adjustment.
READ: Reads and sets conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7

Channel status indicator LEDs:
 The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT
(For remote control and synchronous operation)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 60ºC
Vibration Resistant ±29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)

DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 2.8 A
(When operated on 12 VDC with 4 CDV-40B cards mounted and full load applied)
Dimensions 137.5 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight 2.0 kg
(2.6 kg with 4 CDV-40B card mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card (1 GB)
DVD (Dynamic data acquisition software DCS-100A)
 *DCS-100A is optional for models with suffix "-0".
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX2000-DUMMY

Dimensions

EDX-100A

RCU-41A
Remote Control Unit

Object Product Model EDX-100A
Control Functions ①"REC/PAUSE": Starts/pauses data recording.
②"STOP": Stops data recording.
③"BAL": Executes balance adjustment.
④"VOICE MEMO": Records voice memo.
Indicators REC/PAUSE, BAL
Cable Length Approx. 1.5 m
(Used by connecting to the CONT IN connector of the EDX-100A recorder unit)
Dimensions 35 W × 110 H × 20 D mm
*Excluding protrusions
Weight Approx.200 g

EDB-41B
Battery Unit for Instantaneous Power Failure

EDB-41B

Specifications

Applicable EDX EDX-100A-1(H), EDX-100A-2(H), EDX-100A-4(H), EDX-200A-2H, EDX-200A-4H
Built-in Batteries Battery type: Nickel-Metal Hydride (Ni-MH) battery
Nominal capacity: 730 mAh, nominal voltage: 12 V
External Power Supply Input 11 V to 18 VDC
[DC IN] connector type: RM12BRD-4PH (HIROSE made)
DC power supply, AC adapter (Optional) for EDX-100A, or AC
adapter (Optional) for EDX-200A is used
Power Supply Output External power voltage when using external power drive
Approx. 11 to 15 V when using this units drive (In instantaneous stop)
[DC OUT] terminal model: RM12BRD-4S (Hirose)
When operated on external power supply:
Voltage of the external power supply
When operated on the EDB-41B (During instantaneous power failure):
Approximately 11 to 15 V
[DC OUT] connector type: RM12BRD-4S (HIROSE made)
Charging Method Automatically starts charging the battery by connecting the
external power supply. (Battery charging period: Max. 3.5 hours)
Starts discharging by pressing the [REFRESH] button.
(Refresh period: Max. 6.5 hours)
Indicator [BATTERY LEVEL] LED (With [CHECK] button turned ON.)
Remaining capacity of the built-in battery is 10% or more:
Lights up green
Remaining capacity of the built-in battery is 10% or less:
Lights up red
[CHARGE] LED
During charging----------ON green
During discharging------ON orange
Charging complete------OFF
Buzzer During instantaneous power supply, alarm buzzer is issued.
Operating Temperature 0 to 50°C (However, when charging and refreshing: 0 to 30°C)
Operating Humidity 20 to 90% (Non-condensing)
Storage Temperature -20 to 50°C
Vibration Resistance ±29.42 m/s2 (3 G), 5 to 55 Hz (When operated)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operated)
Impact Resistance 196.10 m/s2 (20 G), 11 ms.
Dimensions 25 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight Approx. 500 g
Backup Time (Reference value) Approx. 30 minutes
When 1 CDV-40B card (8 CHs) is installed to the
EDX-100A-1(H) and full loaded
Approx. 15 minutes
When 2 CDV-40B cards (16 CHs) are installed to the
EDX-100A-2(H) and full loaded
Approx. 5 minutes
When 4 CDV-40B cards (32 CHs) are installed to the
EDX-100A-4(H) and full loaded
Approx. 15 minutes
When 2 CDV-40B cards (16 CHs) are installed to the
EDX-200A-2H and full loaded
Approx. 5 minutes
When 4 CDV-40B cards (32 CHs) are installed to the
EDX-200A-4H and full loaded
* When built-in battery is fully charged and ambient
temperature is 20 to 30°C

Page Top

To Ensure Safe Usage

For LAN connection, use straight cables and a hub.

eBook