EDX-5000A
Memory Recorder/Analyzer

Summary
· High-speed sampling at 200 kHz/32 channels
· Up to 80 input channels
· Simultaneous recording of measuring data and video
· Conditioner cards selectable for specific applications
· Effective real-time processing capability
Features
EDX-5000A is an advanced all-in-one measuring instrument having sophisticated features and high-speed processing capabilities.
It is the high-end model of EDX Series.
Products table
All display
EDX-5000A-64
8 slots, 64 channels

Specifications
Model | EDX-5000A-64-HE: Hard disk drive (HDD) , English EDX-5000A-64-SE: Solid state drive (SSD) , English |
---|---|
Compatible Conditioner Cards | CDV-40B (-F) CVM-41A DPM-42B (-F) DPM-42B-I (-F) CTA-40A CFV-40A CCA-40A (-F) CDV-44AS CDA-44AS CDA-45AS AD-40AS (-F) *The number of CFV-40A that able to be mounted is up to 2 units. |
Channels | Max. 64 (CDV-40B × 8) |
Analog Input | See spec of respective conditioner cards. |
Digital I/O
I/O Points | Max. 8 |
---|---|
I/O Settings | Sets every bit to digital input, digital output, or remote-control input with the same common. *Remote-control input: Start and stop measuring Execute BAL, etc. |
Input Modes | Isolated TTL level input |
Input Voltage | Max. 5 VDC |
Isolation Modes | Digital isolation |
Output Modes | Isolated open-collector output (With 10 kΩ built-in pull-up resistors) |
Output Voltage | 5 VDC |
Output Current | Max. 25 mA (per point) |
Voice Input | 1 channel (To be recorded together with measuring data.) An optional remote control unit RCU-42 is required. |
---|
Sampling Frequencies
Sampling System | Simultaneous sampling of all channels |
---|---|
Sampling Frequencies | 1-2-5 series 1 Hz to 200 kHz: When recording data up to 32 channels (16 channels) 1 Hz to 100 kHz: When recording data up to 64 channels (32 channels) 1 Hz to 50 kHz: When recording data up to 80 channels (64 channels) 1 Hz to 20 kHz: When recording data up to 80 channels (80 channels) 1 Hz to 10 kHz: When real-time simultaneous process is enabled 2n series 2 Hz to 131.072 kHz: When recording data up to 32 channels (16 channels) 2 Hz to 65.536 kHz: When recording data up to 64 channels (32 channels) 2 Hz to 32.768 kHz: When recording data up to 80 channels (64 channels) 2 Hz to 16.384 kHz: When recording data up to 80 channels (80 channels) 2 Hz to 8.192 kHz: When real-time simultaneous process is enabled [Note] AD data format: In 16-bit mode [Note] In the 24-bit mode, the number of channels mentioned in parentheses. |
Data Storage Device | Hard Disk Drive (HDD) Capacity: 300 GB or more Solid State Drive (SSD) Capacity: 30 GB or more |
---|---|
Display | Channel status LED (OVER value of every channel is settable) REC, BUSY, BATTERY, POWER LED With 12.1-inch wide touch panel mounted display |
Operation Keys | Touch panel and front mounted keys(REC, STOP, BAL., OPT). Operation with external keyboard and mouse is also possible. |
External Control Connectors | CONT IN, CONT OUT (remote control,synchronous operation) |
External I/O Connectors | External triggers: TRG IN, TRG OUT External clock: CLK IN, CLK OUT (Output at any frequency division ratio) |
External Interfaces | USB type keyboard USB type mouse VGA connector for monitor USB I/F: 3 USB 2.0 in front, 2 USB 3.0 in rear *The USB 2.0 port in the front is limited to about 100 mA that can be supplied. LAN I/F: 100/1000BASE-T |
Power Supply | 100 to 240 VAC and 10 to 30 VDC, dual supply Built-in batteries against momentary power failure |
Current Consumption | Approx. 1.8 A (For 100 VAC, CDV-40B x 8) |
Operating Temperature | 0 to 40 ºC |
Operating Humidity | 20 to 80% (Non-condensing) |
Storage Temperature | -20 to 60 ºC |
Vibration Resistant | [EDX-5000A-64-HE, EDX-5000A-64-SE] 49.0 m/s2 (5 G), 5 to 55 Hz (When not operating) 29.4 m/s2 (3 G), 5 to 55 Hz (When operating) [EDX-5000A-64-HE] 9.8 m/s2 (1 G), 10 to 200 Hz (When operating) [EDX-5000A-64-SE] 19.6 m/s2 (2 G), 10 to 200 Hz (When operating) |
Impact Resistant | 196.1 m/s2 (20 G), 11 ms |
Dimensions | 365 W × 159 H × 300 D mm (Excluding protrusions) |
Weight | Approx. 11.5 kg (Mainframe only) |
Synchronous Operation | Records data synchronously by connecting multiple EDX-5000A units. Able to connect EDX-5000A and EDX-3000B, EDX-5000A and EDX-200A. Connectable units: 10 (When connecting EDX-5000A-80 units only: Max. 800 channels) When connecting the EDX-200A, the connectable units is max. 8. |
Optional Functions | CAN data acquisition (Input channels: Max. 512) GPS data acquisition (Tracing data acquisition, time synchronous function) |
Online Control | Controlled by DCS-100A |
Compliance | Compliance Directive 2014/30/EU (EMC) Directive 2014/35/EU (LVD) (AC model only) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Standard Accessories | AC power cable P-18 (With 2-pin conversion plug CM-52) DC power cable P-70 Ground wire P-72 Simplified instruction manual CD-R (Instruction manual) EDX accessory bag AC fuse DC fuse Soldering plug for DIO Shell case for DIO plug |
---|---|
Optional Accessories | Synchronous cable N-128 Remote control unit RCU-42A Belt hook Dummy panel for EDX EDX1P-DUMMY EDX2000-DUMMY |
Software ETA-55A Specifications
Measuring Condition Settings
Measuring Channel Conditions | Measurement ON/OFF Measuring modes Range HPF LPF Digital HPF Digital LPF Balance ON/OFF CAL Calibration coefficient Offset Offset zero ON/OFF Unit Channel name Measuring range Rated capacity Rated output Upper-limit check value Lower-limit check value Numeric display digits (Selects any items to display) Inner sensitivity register ON/OFF Input cable Cable compensation value |
---|---|
Recordable Data | Up to remaining disk space of built-in memory |
Manual Measurement | Recording from REC to STOP, or preset data starts from REC |
Interval Measurement | Automatic recording according to designated starting time and recording interval |
Trigger Measurement | Recording and stopping according to preset trigger conditions • Common trigger conditions End trigger: Settable Pre-trigger: Max. 2097152 points per channel Post-trigger: Max. 2097152 points per channel (When AD is set to 24 bits) Trigger data correlates with the number of channels and the AD data. • Analog trigger conditions Trigger channels: Any 1 analog channel Trigger level: Sets in physical quantity. Trigger slope: Up, down • Digital trigger conditions Trigger bit: Any 1 bit Trigger level: 0, 1 • External trigger conditions Trigger slope: Up, down • Complex trigger conditions Trigger source: Selection of any 4 analog/digital channels, an external trigger channel, or a manual trigger channel AND/OR: Be used for analog trigger, digital trigger and external trigger. Trigger level: An physical quantity is set for the analog channel, and 0 or 1 for the digital channel. Trigger slope: Up, down |
TEDS | Reads sensor's information and sets to channel condition automatically. |
Load/Save Measurement Conditions File | Load ME5 file and configure settings according to loaded measurement conditions. Save the measurement conditions in ME5 file. *You can also load/save ME5 file using DCS-100A and EDX-3000B COMPATIBLE SOFTWARE. |
Measuring Operations
Monitor measurement, recording start, pause, stop, balancing, CAL output, etc. | |
Real-time Processing | Simultaneous monitoring and recording of data The sampling frequencies up to 10 kHz are available. |
Video Data Acquisition with a Web Camera
Camera | DirectX compatible Web camera (Recognized by the OS as an imaging device) |
---|---|
Number of Cameras | 1 |
Resolution | Max. 640 x 480 |
Frame Rate | Max. 30 fps |
Saving File Format | AVI format *Resolution and frame rate depend on the camera. *The Web camera is optional. |
Measuring Conditions During Recording Video | Manual mode Manual mode (Data points preset) |
Arithmetic Operation
Digital Filters | Butterworth filters (IIR) Type of filters: LPF, HPF Order of filter: 1 to 8 Amplitude ratio at cut off point: -3 dB Attenuation: -6 x N dB/oct. (N is the filtering orders) *Simultaneous use with built-in LPF of conditioner is possible. |
---|---|
Applicable Operators and Constants | Calculation channels: Max. 64 Calculation conditions: ON/OFF Operators (Max. 200 characters) Unit Numeric display digits Channel name (Max. 40 characters) Calculation zero Calculation zero value Applicable operators and constants: +, -, *, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation |
---|---|
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
Analyzed Data Points | 256, 512, 1024, 2048, 4096, and 8192 |
Analysis Channels | 4 channels/window |
Saving File Format | Kyowa standard file format (KS2) KS2 file version: 01.06 |
---|
Monitor
Y-time Graph | X axis indicates the time, and Y axis the physical values of measurement for a maximum of 8 channels. |
---|---|
X-Y Graph | X and Y axes indicate the measured data, max. 4 channels |
Bar Graph | Up to 80 channels are contained in a graph. Displays max. and min. values are possible. |
Circle Meter | Any one channel is displayed in a circle meter. |
Numeric Display | Up to 80 channels are listed. Displays max. and min. values of each channel are possible. |
FFT Graph | Up to 4 channels of analyzed results are displayed. |
Web Camera | Displays captured images. |
Over Input Indication | Displays the over-input values, background, etc. in red. |
Graph Scale | Capable of displaying auto-scale value on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis). |
Cursors | Available on Y-time graph, X-Y graph, physical values appear at the cursor positions |
Windows | Up to 12 different graph windows are available at the same time. |
Saving Images | Saves each graph as an image file. |
Environmental Settings
Synchronous Operation | Standalone, sync host, or sync guest is selected |
---|
Others
Inner, external oscillators switching, operating beep, balance reference value, AD bits switching, and optional switches selection |
GPS/Multi-channel CAN Optional Functions
CAN Data Recording | Up to 512 channels of CAN data can be recorded for each unit. (CAN data is saved in E4A file format.) *Use the ELA-55A for CAN condition settings. |
---|---|
CAN Trigger | Start/stop recording data by using analog triggers, digital triggers, and complex triggers. *Use the ELA-55A for CAN condition settings. |
Graph Display | Display numerical and analog data in graphs simultaneously. |
Point ZERO (Manual) Measurement | Able to start manual measurement at zero second (at the moment when ms is zero) using the time data received from GPS satellites. |
Interval (GPS Synchronization) Measurement | Able to start interval measurement at zero second (at the moment when ms is zero) using the time data received from GPS satellites. |
GPS Data Recording | Able to monitor and record GPS data (latitude, longitude, speed, bearing, etc.). GPS data is saved in NMEA file format. |
Software ELA-55A Specifications
Measuring Condition Settings
Measuring Channel Conditions | Measurement ON/OFF Measuring modes Range HPF LPF Digital HPF Digital LPF Balance ON/OFF CAL Calibration coefficient Offset Offset zero ON/OFF Unit Channel name Measuring range Rated capacity Rated output Upper-limit check value Lower-limit check value Numeric display digits (Selects any items to display) Inner sensitivity register ON/OFF Input cable Cable compensation value |
---|---|
Recordable Data | Up to remaining disk space of built-in memory |
Manual Measurement | Recording from REC to STOP, or preset data starts from REC |
Interval Measurement | Automatic recording according to designated starting time and recording interval |
Trigger Measurement | • Common trigger conditions End trigger: Settable Pre-trigger or post-trigger: Max. 2097152 points per channel when AD is set to 24 bits. Trigger data correlates with the number of channels and the AD data. • Analog trigger conditions Trigger channels: Any 1 analog channel Trigger level: Sets in physical quantity. Trigger slope: Up, down • Digital trigger conditions Trigger bit: Any 1 bit Trigger level: 0, 1 • External trigger conditions Trigger slope: Up, down • Complex trigger conditions Trigger source: Selection of any 4 analog/digital channels, an external trigger channel, or a manual trigger channel AND/OR: Be used for analog trigger, digital trigger and external trigger. Trigger level: An physical quantity is set for the analog channel, and 0 or 1 for the digital channel. Trigger slope: Up, down |
Reading/Saving Measuring Condition Files | Capable of reading/saving measuring condition files |
Reading/Saving Sensors Files | Capable of reading/saving sensor's CSV files by channel condition |
Digital I/O Settings | I/O points: Max. 8 I/O settings: Sets every bit to digital input, digital output, or remote-control |
TEDS | Reads sensor's information and sets to channel condition automatically. |
Load/Save ME5 File | Load ME5 file and configure settings according to loaded measurement conditions. Save the measurement conditions in ME5 file. *You can also load/save ME5 file using DCS-100A and MAIN SOFTWARE. |
Measuring Operations
Monitor measurement, recording start, pause, stop, balancing, CAL output, etc. | |
Real-time Processing | Simultaneous monitoring and recording of data The sampling frequencies up to 10 kHz are available. |
Video Data Acquisition with a Web Camera
Camera | DirectX compatible Web camera (Recognized by the OS as an imaging device) |
---|---|
Number of Cameras | 1 |
Resolution | Max. 640 x 480 |
Frame Rate | Max. 30 fps |
Saving File Format | AVI format *Resolution and frame rate depend on the camera. *The Web camera is optional. |
Measuring Conditions During Recording Video | Manual mode Manual mode (Data points preset) |
Arithmetic Operation
Digital Filters | Butterworth filters (IIR) Type of filters: LPF, HPF Order of filter: 1 to 8 Amplitude ratio at cut off point: -3 dB Attenuation: -6 x N dB/oct. (N is the filtering orders) *Simultaneous use with built-in LPF of conditioner is possible. |
---|---|
Applicable Operators and Constants | Calculation channels: Max. 64 Calculation conditions: ON/OFF Operators (Max. 200 characters) Unit Numeric display digits Channel name (Max. 40 characters) Calculation zero Calculation zero value Applicable operators and constants: +, -, *, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation |
---|---|
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
Analyzed Data Points | 256, 512, 1024, 2048, 4096, and 8192 |
Analysis Channels | 4 channels/window Max. 8 channels |
Saving | Analyzed results are saved in the FFT analyzed result file format (CSV). |
Saving File Format | Kyowa standard file format (KS2) KS2 file version: 01.06 |
---|
Monitor
Y-time Graph | X axis indicates the time, and Y axis the physical amount of measurement for a maximum of 16 channels. 1 to 10 graphs per window is possible. |
---|---|
Y-time (All channel) Graph | X axis indicates the time, and Y axis the physical amount of measurement. The line color is the same for all channels. |
Y-time (DIV) Graph | X axis indicates the time, and Y axis the physical amount of measurement for a maximum of 16 channels possible. Allows channel's zero position to be set on the Y axis. |
X-Y Graph | Any combination of 8 channels is plotted on X and Y axis |
Bar Graph | Up to 32 channels are contained in a graph. 1 to 4 graphs are indicated on a window. Peak hold ON/OFF |
Digital Graph | X axis indicates the time, and Y axis bit data of a digital channel (Up to 16 bits). 1 to 4 graphs are displayed on a window. |
Circle Meter | Any one channel is displayed in a circle meter. |
Bar Meter | Any one channel is displayed in a horizontal or vertical bar meter. |
Numeric Display | Any one channel, 16 channels or all channels are listed. The max. and min. values of each channel are possible. |
FFT Graph | Up to 4 channels of analyzed results are displayed |
Web Camera | Displays captured images |
Over Input Indication | Capable of displaying the excessive channel values in red, except FFT graphs. |
Graph Scale | Capable of displaying auto-scale and full scale values on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis). Y axis of Y-time graph are switchable among 1-axis, 2-axis, and channel-by-channel |
Display Color | Any color is selectable per window. |
Title, Labels | Any title or X and Y axis labels are specified. |
Windows | 8 numeric windows 8 graph windows (Including an FFT window) |
Auxiliary Lines | Capable of displaying the desired auxiliary lines on the Y-time Graphs (X axis and Y axis), X-Y Graphs (X axis and Y axis), and Bar Graphs (X axis and Y axis). (Up to 4 auxiliary lines each for both X axis and Y axis.) |
Comparative Data | Displays the comparative data (existing KS2 format data) on the Y-time graphs, neither Y-time (All channels) graphs nor Y-time (DIV) graphs, and X-Y graphs for comparing the monitor data. The size of the data file is maximum 10 MB. If the file size exceeds 10 MB, displays the 10 MB data from its head. |
Configuration
Operation Modes | Standalone, sync host, sync guest setting |
---|---|
Control Modes | Off-line, online switching |
Automatic File Conversion | Automatic file conversion upon measurement (CSV, XLS, XLSX, or RPCIII format) |
Others
Inner, external oscillators switching, operating beep, balance reference value, AD bits switching, and optional switches selection |
GPS/Multi-channel CAN Optional Functions
Recording CAN Data | Capable of recording up to 512-channel CAN data per one unit. (In the EDX-5000A data drive, as the E4A file). |
---|---|
CAN Trigger | • Analog trigger conditions Trigger channel: Any CAN channel Trigger level: Set in CAN data Trigger slope: Up, down • Digital trigger conditions Trigger channel: Any 1 bit of CAN channel Trigger level: 0, 1 • Complex trigger conditions Trigger source: Any 4 channels AND/OR Analog trigger: Logic is possible. Digital trigger: Logic is possible. Trigger level Analog channel: CAN data Digital channel: 0, 1 Trigger slope: Up, down |
Communications Conditions | Communication standards Communication speed Terminal resistance *Sample points, sampling frequency, resynchronization jump width are set automatically. |
Measuring ID Conditions | Port No Format Frame ID Data length |
Measuring Channel Conditions | Start bit Bit length Data type Endian Calibration coefficient Offset (Conditions for conversion of extracting CAN data to physical quantity) |
Graph Display | Simultaneous display of graph Numerical value Analog data |
Read CANdb Files | File: DBC format The number of “Network Node”: Maximum 1024 The number of “Message”: Maximum 2048 The number of “Signal”: Maximum 4096 |
Point ZERO (Manual Measurement) | Starts the manual measurement at 0 ms by using the time data, received from the GPS satellite. |
Interval (GPS Synchronization Measurement) | Starts the interval measurement at 0 ms by using the time data, received from the GPS satellite. |
Recording GPS Data | Monitors/records the GPS data (latitude, longitude, speed, azimuth, etc.). The ELA-55A saves the GPS data in the EDX-5000A data drive (in the NMEA format). |
Data Reproduction, Data Analysis Specifications
Data Reproduction
Graph Display | 4 patterns of display condition are set for a graph. Allows 1, 2, or 4 graphs to be displayed |
---|---|
Y-time Graph | Up to 16 channels per graph, and allows Y axis to be scaled automatically. |
X-Y Graph | 1 graph fixed, allows any 4 channels to be plotted on X- and Y-axis. Both axes to be scaled automatically. |
All Data Display | Displays all data by every 4 channels. |
Numeric Data Display | Lists any 16 channels data |
Cursor | Numeric display of the engineering value of cursor position. Zoom in data between 2 cursors. Display max. and min. data between 2 cursors. |
Scrolling | Scrolls X axis on Y-time graphs. |
Data File Editing | Extracting of an arbitrary range or arbitrary channel from collected data file and conversion to a CSV format file are possible. Data file titles, comments, channel conditions display and editing are possible. |
Max. and Min. Display | Showing max. and min. data of each channel (Max. 5-data) , 400-data around the max. or min. are shown in graphs. |
KS2 File | Block number support (1 block display, all block display). Displays and plays back the audio data. |
Video Playback | Playback Backward Repeat Frame-by-frame forward Frame-by-frame backward Jump to the beginning Jump to the end Set the beginning position Set the end position Playback speed: ×0.1 to ×20 Plays back the measured data, video and GPS data at the same time. |
AVI Files | Playback frame rate Start frame No. (time) |
Static Measuring Files | Reproduces the static measuring files (CSV format files). |
Data Analysis
Static Processing | A list of maxima, minima, averages and standard deviations in a desired section of the data file. The results are saved in CSV files. |
---|---|
Arithmetic Operations | Inter-channel operations for up to 2 files. The result is saved in a new file (Up to 320 expressions is possible). Expression: Up to 200 characters Applicable operators and constants: +, -, ×, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation Coherence Transfer function |
---|---|
Analyzed Data Points | 256, 512, 1024, 2048, 4096, 8192, 16384, and 32768 |
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
LPF | 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000 Hz and FLAT, 12 steps |
Integration Times | 0 (None) to 2 |
Average Times | 0 or more (0: whole waveform) |
Shift Data Points | 2 or more |
Analysis Types and Graphs | [Linear spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase [Power spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: --- [Cross-spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase [Auto-correlation] Y-time graph: Yes Analysis graph 1: Correlation Analysis graph 2: --- [Cross-correlation] Y-time graph: Yes Analysis graph 1: Correlation Analysis graph 2: --- [Coherence] Y-time graph: Yes Analysis graph 1: Coherence Analysis graph 2: --- [Transfer function] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase Analyzed results are saved in CSV files. |
Histogram Analysis
Algorithm Types | Peak/valley Maxima/minima 1D rainflow Amplitude 1D time at level 1D rainflow + peak/valley 1D rainflow + maxima/minima 2D rainflow |
---|---|
Slices | 1D algorithm: Even numbers from 10 (±5) to 256 (±128) 2D algorithm: Even numbers from 10 to 50 Slice width, hysteresis, offset (For maxima/minima), etc. to be specified. Results: Tabular or drawing display (3D display for 2D rainflow) |
Life Prediction Processing | Predicts life from the result of histogram analysis of 1D rainflow method, 2D rainflow method, or amplitude method. The life prediction data is shown and saved as a file. (Allows S-N data files to be read.) |
Filtering | Digital IIR filters, 4th order Butterworth (Cutoff: -6dB, no phase delay) HPF & LPF: FLAT to 500 k Hz (Effective up to one-half of the sampling frequency) Mirroring Analysis results are saved as an additional format |
Differentiation/Integration | Differential/integration times: 0 (None) to 2 Analysis results are saved as additional format |
Utility
Multiple Files Conversion | Conversion to CSV, XLS, XLSX, or RPCIII format |
---|---|
File Coupling | Multiple files (Host and guests) acquired in synchronized operation are coupled into one file. |
Reverse Conversion | Data files converted by this software into CSV format are converted back to KS2 format. |
File Division | Extracts the specified block No. data of the data file into single file. |
Batch Analysis | Analysis of multiple files under same conditions at one time. Histogram analysis, filtering and differentiation/integration are available. |
Overwriting of Multiple Files | Up to 16 data files are displayed and overlapped as Y-time data. Allows start point of each file to be set. |
Multiple Files Conversion | Converts multiple KS2 files acquired in the interval measurement into a CSV file. |
Dimensions

EDX-5000A-80
10 slots, 80 channels

Specifications
Model | EDX-5000A-80-HE: Hard disk drive (HDD) , English EDX-5000A-80-SE: Solid state drive (SSD) , English |
---|---|
Compatible Conditioner Cards | CDV-40B (-F) CVM-41A DPM-42B (-F) DPM-42B-I (-F) CTA-40A CFV-40A CCA-40A (-F) CDV-44AS CDA-44AS CDA-45AS AD-40AS (-F) *The number of CFV-40A that able to be mounted is up to 2 units. |
Channels | Max. 80 (CDV-40B × 10) |
Analog Input | See spec of respective conditioner cards. |
Digital I/O
I/O Points | Max. 8 |
---|---|
I/O Settings | Sets every bit to digital input, digital output, or remote-control input with the same common. *Remote-control input: Start and stop measuring Execute BAL, etc. |
Input Modes | Isolated TTL level input |
Input Voltage | Max. 5 VDC |
Isolation Modes | Digital isolation |
Output Modes | Isolated open-collector output (With 10 kΩ built-in pull-up resistors) |
Output Voltage | 5 VDC |
Output Current | Max. 25 mA (per point) |
Voice Input | 1 channel (To be recorded together with measuring data.) An optional remote control unit RCU-42 is required. |
---|
Sampling Frequencies
Sampling System | Simultaneous sampling of all channels |
---|---|
Sampling Frequencies | 1-2-5 series 1 Hz to 200 kHz: When recording data up to 32 channels (16 channels) 1 Hz to 100 kHz: When recording data up to 64 channels (32 channels) 1 Hz to 50 kHz: When recording data up to 80 channels (64 channels) 1 Hz to 20 kHz: When recording data up to 80 channels (80 channels) 1 Hz to 10 kHz: When real-time simultaneous process is enabled 2n series 2 Hz to 131.072 kHz: When recording data up to 32 channels (16 channels) 2 Hz to 65.536 kHz: When recording data up to 64 channels (32 channels) 2 Hz to 32.768 kHz: When recording data up to 80 channels (64 channels) 2 Hz to 16.384 kHz: When recording data up to 80 channels (80 channels) 2 Hz to 8.192 kHz: When real-time simultaneous process is enabled [Note] AD data format: In 16-bit mode [Note] In the 24-bit mode, the number of channels mentioned in parentheses. |
Data Storage Device | Hard Disk Drive (HDD) Capacity: 300 GB or more Solid State Drive (SSD) Capacity: 30 GB or more |
---|---|
Display | Channel status LED (OVER value of every channel is settable) REC, BUSY, BATTERY, POWER LED With 12.1-inch wide touch panel mounted display |
Operation Keys | Touch panel and front mounted keys(REC, STOP, BAL., OPT). Operation with external keyboard and mouse is also possible. |
External Control Connectors | CONT IN, CONT OUT (remote control,synchronous operation) |
External I/O Connectors | External triggers: TRG IN, TRG OUT External clock: CLK IN, CLK OUT (Output at any frequency division ratio) |
External Interfaces | USB type keyboard USB type mouse VGA connector for monitor USB I/F: 3 USB 2.0 in front, 2 USB 3.0 in rear *The USB 2.0 port in the front is limited to about 100 mA that can be supplied. LAN I/F: 100/1000BASE-T |
Power Supply | 100 to 240 VAC and 10 to 30 VDC, dual supply Built-in batteries against momentary power failure |
Current Consumption | Approx. 2.0 A (For 100 VAC, CDV-40B x 10) |
Operating Temperature | 0 to 40 ºC |
Operating Humidity | 20 to 80% (Non-condensing) |
Storage Temperature | -20 to 60 ºC |
Vibration Resistant | [EDX-5000A-80-HE, EDX-5000A-80-SE] 49.0 m/s2 (5 G), 5 to 55 Hz (When not operating) 29.4 m/s2 (3 G), 5 to 55 Hz (When operating) [EDX-5000A-80-HE] 9.8 m/s2 (1 G), 10 to 200 Hz (When operating) [EDX-5000A-80-SE] 19.6 m/s2 (2 G), 10 to 200 Hz (When operating) |
Impact Resistant | 196.1 m/s2 (20 G), 11 ms |
Dimensions | 410 W × 159 H × 300 D mm (Excluding protrusions) |
Weight | Approx. 12.5 kg (Mainframe only) |
Synchronous Operation | Records data synchronously by connecting multiple EDX-5000A units. Able to connect EDX-5000A and EDX-3000B, EDX-5000A and EDX-200A. Connectable units: 10 (When connecting EDX-5000A-80 units only: Max. 800 channels) When connecting the EDX-200A, the connectable units is max. 8. |
Optional Functions | CAN data acquisition (Input channels: Max. 512) GPS data acquisition (Tracing data acquisition, time synchronous function) |
Online Control | Controlled by DCS-100A |
Compliance | Compliance Directive 2014/30/EU (EMC) Directive 2014/35/EU (LVD) (AC model only) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Standard Accessories | AC power cable P-18 (With 2-pin conversion plug CM-52) DC power cable P-70 Ground wire P-72 Simplified instruction manual CD-R (Instruction manual) EDX accessory bag AC fuse DC fuse Soldering plug for DIO Shell case for DIO plug |
---|---|
Optional Accessories | Synchronous cable N-128 Remote control unit RCU-42A Belt hook Dummy panel for EDX EDX1P-DUMMY EDX2000-DUMMY |
Software ETA-55A Specifications
Measuring Condition Settings
Measuring Channel Conditions | Measurement ON/OFF Measuring modes Range HPF LPF Digital HPF Digital LPF Balance ON/OFF CAL Calibration coefficient Offset Offset zero ON/OFF Unit Channel name Measuring range Rated capacity Rated output Upper-limit check value Lower-limit check value Numeric display digits (Selects any items to display) Inner sensitivity register ON/OFF Input cable Cable compensation value |
---|---|
Recordable Data | Up to remaining disk space of built-in memory |
Manual Measurement | Recording from REC to STOP, or preset data starts from REC |
Interval Measurement | Automatic recording according to designated starting time and recording interval |
Trigger Measurement | Recording and stopping according to preset trigger conditions • Common trigger conditions End trigger: Settable Pre-trigger: Max. 2097152 points per channel Post-trigger: Max. 2097152 points per channel (When AD is set to 24 bits) Trigger data correlates with the number of channels and the AD data. • Analog trigger conditions Trigger channels: Any 1 analog channel Trigger level: Sets in physical quantity. Trigger slope: Up, down • Digital trigger conditions Trigger bit: Any 1 bit Trigger level: 0, 1 • External trigger conditions Trigger slope: Up, down • Complex trigger conditions Trigger source: Selection of any 4 analog/digital channels, an external trigger channel, or a manual trigger channel AND/OR: Be used for analog trigger, digital trigger and external trigger. Trigger level: An physical quantity is set for the analog channel, and 0 or 1 for the digital channel. Trigger slope: Up, down |
TEDS | Reads sensor's information and sets to channel condition automatically. |
Load/Save Measurement Conditions File | Load ME5 file and configure settings according to loaded measurement conditions. Save the measurement conditions in ME5 file. *You can also load/save ME5 file using DCS-100A and EDX-3000B COMPATIBLE SOFTWARE. |
Measuring Operations
Monitor measurement, recording start, pause, stop, balancing, CAL output, etc. | |
Real-time Processing | Simultaneous monitoring and recording of data The sampling frequencies up to 10 kHz are available. |
Video Data Acquisition with a Web Camera
Camera | DirectX compatible Web camera (Recognized by the OS as an imaging device) |
---|---|
Number of Cameras | 1 |
Resolution | Max. 640 x 480 |
Frame Rate | Max. 30 fps |
Saving File Format | AVI format *Resolution and frame rate depend on the camera. *The Web camera is optional. |
Measuring Conditions During Recording Video | Manual mode Manual mode (Data points preset) |
Arithmetic Operation
Digital Filters | Butterworth filters (IIR) Type of filters: LPF, HPF Order of filter: 1 to 8 Amplitude ratio at cut off point: -3 dB Attenuation: -6 x N dB/oct. (N is the filtering orders) *Simultaneous use with built-in LPF of conditioner is possible. |
---|---|
Applicable Operators and Constants | Calculation channels: Max. 64 Calculation conditions: ON/OFF Operators (Max. 200 characters) Unit Numeric display digits Channel name (Max. 40 characters) Calculation zero Calculation zero value Applicable operators and constants: +, -, *, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation |
---|---|
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
Analyzed Data Points | 256, 512, 1024, 2048, 4096, and 8192 |
Analysis Channels | 4 channels/window |
Saving File Format | Kyowa standard file format (KS2) KS2 file version: 01.06 |
---|
Monitor
Y-time Graph | X axis indicates the time, and Y axis the physical values of measurement for a maximum of 8 channels. |
---|---|
X-Y Graph | X and Y axes indicate the measured data, max. 4 channels |
Bar Graph | Up to 80 channels are contained in a graph. Displays max. and min. values are possible. |
Circle Meter | Any one channel is displayed in a circle meter. |
Numeric Display | Up to 80 channels are listed. Displays max. and min. values of each channel are possible. |
FFT Graph | Up to 4 channels of analyzed results are displayed. |
Web Camera | Displays captured images. |
Over Input Indication | Displays the over-input values, background, etc. in red. |
Graph Scale | Capable of displaying auto-scale value on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis). |
Cursors | Available on Y-time graph, X-Y graph, physical values appear at the cursor positions |
Windows | Up to 12 different graph windows are available at the same time. |
Saving Images | Saves each graph as an image file. |
Environmental Settings
Synchronous Operation | Standalone, sync host, or sync guest is selected |
---|
Others
Inner, external oscillators switching, operating beep, balance reference value, AD bits switching, and optional switches selection |
GPS/Multi-channel CAN Optional Functions
CAN Data Recording | Up to 512 channels of CAN data can be recorded for each unit. (CAN data is saved in E4A file format.) *Use the ELA-55A for CAN condition settings. |
---|---|
CAN Trigger | Start/stop recording data by using analog triggers, digital triggers, and complex triggers. *Use the ELA-55A for CAN condition settings. |
Graph Display | Display numerical and analog data in graphs simultaneously. |
Point ZERO (Manual) Measurement | Able to start manual measurement at zero second (at the moment when ms is zero) using the time data received from GPS satellites. |
Interval (GPS Synchronization) Measurement | Able to start interval measurement at zero second (at the moment when ms is zero) using the time data received from GPS satellites. |
GPS Data Recording | Able to monitor and record GPS data (latitude, longitude, speed, bearing, etc.). GPS data is saved in NMEA file format. |
Software ELA-55A Specifications
Measuring Condition Settings
Measuring Channel Conditions | Measurement ON/OFF Measuring modes Range HPF LPF Digital HPF Digital LPF Balance ON/OFF CAL Calibration coefficient Offset Offset zero ON/OFF Unit Channel name Measuring range Rated capacity Rated output Upper-limit check value Lower-limit check value Numeric display digits (Selects any items to display) Inner sensitivity register ON/OFF Input cable Cable compensation value |
---|---|
Recordable Data | Up to remaining disk space of built-in memory |
Manual Measurement | Recording from REC to STOP, or preset data starts from REC |
Interval Measurement | Automatic recording according to designated starting time and recording interval |
Trigger Measurement | • Common trigger conditions End trigger: Settable Pre-trigger or post-trigger: Max. 2097152 points per channel when AD is set to 24 bits. Trigger data correlates with the number of channels and the AD data. • Analog trigger conditions Trigger channels: Any 1 analog channel Trigger level: Sets in physical quantity. Trigger slope: Up, down • Digital trigger conditions Trigger bit: Any 1 bit Trigger level: 0, 1 • External trigger conditions Trigger slope: Up, down • Complex trigger conditions Trigger source: Selection of any 4 analog/digital channels, an external trigger channel, or a manual trigger channel AND/OR: Be used for analog trigger, digital trigger and external trigger. Trigger level: An physical quantity is set for the analog channel, and 0 or 1 for the digital channel. Trigger slope: Up, down |
Reading/Saving Measuring Condition Files | Capable of reading/saving measuring condition files |
Reading/Saving Sensors Files | Capable of reading/saving sensor's CSV files by channel condition |
Digital I/O Settings | I/O points: Max. 8 I/O settings: Sets every bit to digital input, digital output, or remote-control |
TEDS | Reads sensor's information and sets to channel condition automatically. |
Load/Save ME5 File | Load ME5 file and configure settings according to loaded measurement conditions. Save the measurement conditions in ME5 file. *You can also load/save ME5 file using DCS-100A and MAIN SOFTWARE. |
Measuring Operations
Monitor measurement, recording start, pause, stop, balancing, CAL output, etc. | |
Real-time Processing | Simultaneous monitoring and recording of data The sampling frequencies up to 10 kHz are available. |
Video Data Acquisition with a Web Camera
Camera | DirectX compatible Web camera (Recognized by the OS as an imaging device) |
---|---|
Number of Cameras | 1 |
Resolution | Max. 640 x 480 |
Frame Rate | Max. 30 fps |
Saving File Format | AVI format *Resolution and frame rate depend on the camera. *The Web camera is optional. |
Measuring Conditions During Recording Video | Manual mode Manual mode (Data points preset) |
Arithmetic Operation
Digital Filters | Butterworth filters (IIR) Type of filters: LPF, HPF Order of filter: 1 to 8 Amplitude ratio at cut off point: -3 dB Attenuation: -6 x N dB/oct. (N is the filtering orders) *Simultaneous use with built-in LPF of conditioner is possible. |
---|---|
Applicable Operators and Constants | Calculation channels: Max. 64 Calculation conditions: ON/OFF Operators (Max. 200 characters) Unit Numeric display digits Channel name (Max. 40 characters) Calculation zero Calculation zero value Applicable operators and constants: +, -, *, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation |
---|---|
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
Analyzed Data Points | 256, 512, 1024, 2048, 4096, and 8192 |
Analysis Channels | 4 channels/window Max. 8 windows |
Saving | Analyzed results are saved in the FFT analyzed result file format (CSV). |
Saving File Format | Kyowa standard file format (KS2) KS2 file version: 01.06 |
---|
Monitor
Y-time Graph | X axis indicates the time, and Y axis the physical amount of measurement for a maximum of 16 channels. 1 to 10 graphs per window is possible. |
---|---|
Y-time (All channel) Graph | X axis indicates the time, and Y axis the physical amount of measurement. The line color is the same for all channels. |
Y-time (DIV) Graph | X axis indicates the time, and Y axis the physical amount of measurement for a maximum of 16 channels possible. Allows channel's zero position to be set on the Y axis. |
X-Y Graph | Any combination of 8 channels is plotted on X and Y axis |
Bar Graph | Up to 32 channels are contained in a graph. 1 to 4 graphs are indicated on a window. Peak hold ON/OFF |
Digital Graph | X axis indicates the time, and Y axis bit data of a digital channel (Up to 16 bits). 1 to 4 graphs are displayed on a window. |
Circle Meter | Any one channel is displayed in a circle meter. |
Bar Meter | Any one channel is displayed in a horizontal or vertical bar meter. |
Numeric Display | Any one channel, 16 channels or all channels are listed. The max. and min. values of each channel are possible. |
FFT Graph | Up to 4 channels of analyzed results are displayed |
Web Camera | Displays captured images |
Over Input Indication | Capable of displaying the excessive channel values in red, except FFT graphs. |
Graph Scale | Capable of displaying auto-scale and full scale values on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis). Y axis of Y-time graph are switchable among 1-axis, 2-axis, and channel-by-channel |
Display Color | Any color is selectable per window. |
Title, Labels | Any title or X and Y axis labels are specified. |
Windows | 8 numeric windows 8 graph windows (Including an FFT window) |
Auxiliary Lines | Capable of displaying the desired auxiliary lines on the Y-time Graphs (X axis and Y axis), X-Y Graphs (X axis and Y axis), and Bar Graphs (X axis and Y axis). (Up to 4 auxiliary lines each for both X axis and Y axis.) |
Comparative Data | Displays the comparative data (existing KS2 format data) on the Y-time graphs, neither Y-time (All channels) graphs nor Y-time (DIV) graphs, and X-Y graphs for comparing the monitor data. The size of the data file is maximum 10 MB. If the file size exceeds 10 MB, displays the 10 MB data from its head. |
Configuration
Operation Modes | Standalone, sync host, sync guest setting |
---|---|
Control Modes | Off-line, online switching |
Automatic File Conversion | Automatic file conversion upon measurement (CSV, XLS, XLSX, or RPCIII format) |
Others
Inner, external oscillators switching, operating beep, balance reference value, AD bits switching, and optional switches selection |
GPS/Multi-channel CAN Optional Functions
Recording CAN Data | Capable of recording up to 512-channel CAN data per one unit. (In the EDX-5000A data drive, as the E4A file). |
---|---|
CAN Trigger | • Analog trigger conditions Trigger channel: Any CAN channel Trigger level: Set in CAN data Trigger slope: Up, down • Digital trigger conditions Trigger channel: Any 1 bit of CAN channel Trigger level: 0, 1 • Complex trigger conditions Trigger source: Any 4 channels AND/OR Analog trigger: Logic is possible. Digital trigger: Logic is possible. Trigger level Analog channel: CAN data Digital channel: 0, 1 Trigger slope: Up, down |
Communications Conditions | Communication standards Communication speed Terminal resistance *Sample points, sampling frequency, resynchronization jump width are set automatically. |
Measuring ID Conditions | Port No Format Frame ID Data length |
Measuring Channel Conditions | Start bit Bit length Data type Endian Calibration coefficient Offset (Conditions for conversion of extracting CAN data to physical quantity) |
Graph Display | Simultaneous display of graph Numerical value Analog data |
Read CANdb Files | File: DBC format The number of “Network Node”: Maximum 1024 The number of “Message”: Maximum 2048 The number of “Signal”: Maximum 4096 |
Point ZERO (Manual Measurement) | Starts the manual measurement at 0 ms by using the time data, received from the GPS satellite. |
Interval (GPS Synchronization Measurement) | Starts the interval measurement at 0 ms by using the time data, received from the GPS satellite. |
Recording GPS Data | Monitors/records the GPS data (latitude, longitude, speed, azimuth, etc.). The ELA-55A saves the GPS data in the EDX-5000A data drive (in the NMEA format). |
Data Reproduction, Data Analysis Specifications
Data Reproduction
Graph Display | 4 patterns of display condition are set for a graph. Allows 1, 2, or 4 graphs to be displayed |
---|---|
Y-time Graph | Up to 16 channels per graph, and allows Y axis to be scaled automatically. |
X-Y Graph | 1 graph fixed, allows any 4 channels to be plotted on X- and Y-axis. Both axes to be scaled automatically. |
All Data Display | Displays all data by every 4 channels. |
Numeric Data Display | Lists any 16 channels data |
Cursor | Numeric display of the engineering value of cursor position. Zoom in data between 2 cursors. Display max. and min. data between 2 cursors. |
Scrolling | Scrolls X axis on Y-time graphs. |
Data File Editing | Extracting of an arbitrary range or arbitrary channel from collected data file and conversion to a CSV format file are possible. Data file titles, comments, channel conditions display and editing are possible. |
Max. and Min. Display | Showing max. and min. data of each channel (Max. 5-data) , 400-data around the max. or min. are shown in graphs. |
KS2 File | Block number support (1 block display, all block display). Displays and plays back the audio data. |
Video Playback | Playback Backward Repeat Frame-by-frame forward Frame-by-frame backward Jump to the beginning Jump to the end Set the beginning position Set the end position Playback speed: ×0.1 to ×20 Plays back the measured data, video and GPS data at the same time. |
AVI Files | Playback frame rate Start frame No. (time) |
Static Measuring Files | Reproduces the static measuring files (CSV format files). |
Data Analysis
Static Processing | A list of maxima, minima, averages and standard deviations in a desired section of the data file. The results are saved in CSV files. |
---|---|
Arithmetic Operations | Inter-channel operations for up to 2 files. The result is saved in a new file (Up to 320 expressions is possible). Expression: Up to 200 characters Applicable operators and constants: +, -, ×, /, ^ [power], PI [π], () Functions: SQR Square root ABS Absolute value SIN Sine COS Cosine TAN Tangent ASIN Arc sine (Return value: Radian) ACOS Arc cosine (Return value: Radian) ATAN Arc tangent (Return value: Radian) DSIN (Return value: Angle) DCOS (Return value: Angle) DTAN (Return value: Angle) LOG Common logarithm LN Natural logarithm EXP Exponent HMX Max. principal strain HMN Min. principal strain HSM Max. shearing strain SMX Max. principal stress SMN Min. principal stress SSM Max. shearing stress DEG Principal strain direction |
FFT Analysis
Analysis Types | Linear spectrum Power spectrum Cross spectrum Auto-correlation Cross-correlation Coherence Transfer function |
---|---|
Analyzed Data Points | 256, 512, 1024, 2048, 4096, 8192, 16384, and 32768 |
Window Functions | OFF Hamming Hanning Fejer Blackman Gaussian |
LPF | 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000 Hz and FLAT, 12 steps |
Integration Times | 0 (None) to 2 |
Average Times | 0 or more (0: whole waveform) |
Shift Data Points | 2 or more |
Analysis Types and Graphs | [Linear spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase [Power spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: --- [Cross-spectrum] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase [Auto-correlation] Y-time graph: Yes Analysis graph 1: Correlation Analysis graph 2: --- [Cross-correlation] Y-time graph: Yes Analysis graph 1: Correlation Analysis graph 2: --- [Coherence] Y-time graph: Yes Analysis graph 1: Coherence Analysis graph 2: --- [Transfer function] Y-time graph: Yes Analysis graph 1: Amplitude (linear)/amplitude (log) Analysis graph 2: Phase Analyzed results are saved in CSV files. |
Histogram Analysis
Algorithm Types | Peak/valley Maxima/minima 1D rainflow Amplitude 1D time at level 1D rainflow + peak/valley 1D rainflow + maxima/minima 2D rainflow |
---|---|
Slices | 1D algorithm: Even numbers from 10 (±5) to 256 (±128) 2D algorithm: Even numbers from 10 to 50 Slice width, hysteresis, offset (For maxima/minima), etc. to be specified. Results: Tabular or drawing display (3D display for 2D rainflow) |
Life Prediction Processing | Predicts life from the result of histogram analysis of 1D rainflow method, 2D rainflow method, or amplitude method. The life prediction data is shown and saved as a file. (Allows S-N data files to be read.) |
Filtering | Digital IIR filters, 4th order Butterworth (Cutoff: -6dB, no phase delay) HPF & LPF: FLAT to 500 k Hz (Effective up to one-half of the sampling frequency) Mirroring Analysis results are saved as an additional format |
Differentiation/Integration | Differential/integration times: 0 (None) to 2 Analysis results are saved as additional format |
Utility
Multiple Files Conversion | Conversion to CSV, XLS, XLSX, or RPCIII format |
---|---|
File Coupling | Multiple files (Host and guests) acquired in synchronized operation are coupled into one file. |
Reverse Conversion | Data files converted by this software into CSV format are converted back to KS2 format. |
File Division | Extracts the specified block No. data of the data file into single file. |
Batch Analysis | Analysis of multiple files under same conditions at one time. Histogram analysis, filtering and differentiation/integration are available. |
Overwriting of Multiple Files | Up to 16 data files are displayed and overlapped as Y-time data. Allows start point of each file to be set. |
Multiple Files Conversion | Converts multiple KS2 files acquired in the interval measurement into a CSV file. |
Dimensions

EGPC-50A
GPS/Multi-channel CAN Module

Specifications
Applicable Model | Mounted in the EDX-5000A |
---|
I/O Ports
GPS/CAN Shared Port | 1 Dsub connector 9 pins (male) |
---|---|
CAN Only Port | 1 Dsub connector 9 pins (male) |
Input CAN Channels | Max. 512 |
---|---|
Applicable CAN Versions | CAN2.0A/B (Conforming to ISO-11898, ISO-11519-2) |
Communication Speed | [High Speed CAN] 1000, 800, 500, 250, 125, 100, 83.3, 62.5, 50,33.3, 25, 20, 10 kbps [Low Speed CAN] 125, 100, 83.3, 62.5, 50, 33.3, 25, 20, 10 kbps |
CAN Data Output
Output Start Cond | Output an arbitrary CAN data when starting the AD conversion. |
---|---|
Output Stop Cond | Output an arbitrary CAN data when the AD conversion is stopped. |
Output Interval Cond | Output an arbitrary CAN data at the preset constant frequency. |
Output Manual Cond | Output an arbitrary CAN data at arbitrary timing. |
Measurable GPS Data | Latitude Longitude Height Course Speed Time GPS status Number of satellites, etc. Saving format: NMEA format |
---|---|
Time Synchronization Function | Synchronizes the recording start time of EDX-5000A units by using the time data received from GPS satellites. |
Operating Temperature | 0 to 40ºC |
Operating Humidity | 20 to 80% (Non-condensing) |
Storage Temperature | -20 to 60ºC |
Compliance | Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Standard Accessories | GPS sensor (Cable length: 5 m) |
---|
RCU-42A
Remote Control Unit

Object Product Model | EDX-200A EDX-5000A |
---|---|
Control Functions | REC/PAUSE (Starts/pauses data acquisition) STOP (Stops data acquisition) BAL (Balancing) OPT. (Optional function) VOICE MEMO (Recording with the built-in microphone) |
Indication | Recording, pausing and balancing are indicated with LED. |
Buzzer | Equivalent to the EDX recorder unit buzzer |
Cable Length | Approx. 1.5 m |
Dimensions | 35 W× 125 H×22 D (mm) *Excluding protrusions |
Weight | Approx. 220 g |