MCE-24A
Online Conditioner System

Summary

Excluding the items on the following products table, all products are no longer in production.

Features

The MCE-24A is Online Conditioner System, in which conditioner cards are mounted for measuring different types of signals in a variety of combinations.

Products table

All display

DPM-32A
Strain Amplifier Card

DPM-32A

Specifications

Measuring Targets Strain gage
Strain-gage transducers
Channels 2
Applicable Bridge Resistance 60 Ω to 1 kΩ
Gage Factor 2.00 fixed
Bridge Excitation 12 kHz sine wave 2 Vrms
Balance Adjustment Resistance: ±2% (±10000 ×10-6 strain) or more
Capacitance: 2000 pF or more
Balance Adjustment Method Resistance: True electron auto balance (Saved in nonvolatile memory)
Accuracy: ±0.5 ×10-6 strain (With the range set to 100 ×10-6 strain)
Capacitance: CST method (Capacitance self-tracking)
Output 2/channel
(The same voltage is output to BNC connector and concentrated output connector.)
±5 V FS (With full scale input in each range; load 5 kΩ or more)
Measuring Range 8 steps of 100, 200, 500, 1000, 2000, 5000, 10000 ×10-6 strain and OFF
Accuracy: ±0.5%
Vernier ×1.0 to ×0.4 (0.1 step)
Nonlinearity Within ±0.2% FS
Calibration Strain ±100% and ±50% of each range
Accuracy: Within ± (0.5% +0.5 ×10-6 strain)
Frequency Response DC to 5 kHz (Deviation ±10%)
LPF Transfer characteristic : 2th order Butterworth
Cutoff frequencies : 6 steps of 10, 30, 100, 300 Hz, 1k Hz and Flat
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-12 dB±1) dB/oct.
SN Ratio 40 dBp-p or more (100 ×10-6 strain range)

CDV-31A
Strain/Voltage Measurement Card

CDV-31A

Specifications

Measuring Targets Strain gage
Strain-gage transducer
Voltage
Channels 2
Input Modes [Strain measurement]
 Balance differential input

[Voltage measurement]
 Unbalanced input
Input Resistance [Strain measurement]
 (10 MΩ+10 MΩ) or more

[Voltage measurement]
 Approx. 1 MΩ
Gage Factor 2.00 fixed
Bridge Excitation [Strain measurement]
 10, 5, 2, 0.5 VDC switchable
Applicable Bridge Resistance [Strain measurement]
 BV 0.5 V : 60 Ω to1 kΩ
 BV 2 V : 60 Ω to 1 kΩ
 BV 5 V : 350 Ω to 1 kΩ
 BV 10 V : 350 Ω to 1 kΩ
Balance Adjustment [Strain measurement]
 Resistance: ±2% (±10000 ×10-6 strain) or more
Balance Adjustment Method [Strain measurement]
 True electron auto balance
 Accuracy: Within ±2.5 ×10-6 strain
 (With BV 10 V and range 100 ×10-6 strain)
Output 2/channel
(The same voltage is output to BNC connector and concentrated output connector.)

±5 VFS (With full scale input in each range and load 5 kΩ or more)
Measuring Range [Strain measurement]
BV 0.5 V: 7 steps 2k, 5k, 10k, 20k, 50k, 100k ×10-6 strain and OFF
BV 2 V: 7 steps of 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF
BV 5 V: 7 steps of 200, 500, 1k, 2k, 5k, 10k ×10-6 strain and OFF
BV 10 V : 7 steps of 100, 200, 500, 1000, 2000, 5000 ×10-6 strain and OFF

[Voltage measurement]
6 steps of 0.5, 1, 2, 5, 10 V and OFF
Vernier ×1.0 to ×0.4 (0.1 step)
Calibration Strain [Strain measurement]
 ±100% and ±50% in each measuring range
 *Accuracy: Within ±(0.3% + 0.5 ×10-6 strain)

[Voltage measurement]
 ±100% and ±50% in each measuring range
 *Accuracy: Within ±0.3%
Frequency Response DC to 100 kHz (Deviation +0.5 dB, -3 dB)
Nonlinearity Within ±0.05% FS
LPF Transfer characteristic : 2th order Butterworth
Cutoff frequencies : 8 steps of 10, 30, 100, 300, 1, 3, 10 kHz and Flat
Amplitude ratio at cutoff point : -3 dB ±1 dB
Attenuation : (-12 ±1) dB/oct.