NTB-100/200 Series
Network Terminal Box

  • TEDS

NTB-100/200 Series

Summary

· CAN data output and one cable connection
· Digitized data transmission thereby strong against noise
· Compact & lightweight, so easy to install on site

Features

The NTB-100/200 Series is a data logger, which digitizes data adjacent to the sensor and can be decentralized arrangement.
A single unit can measure 4 channels, and up to 99 units can be connected, so measurement up to 396 channels is possible.

Products table

All display

NTB-100B-120
Constant-voltage, One-touch terminal, 120Ω

NTB-100B-120
  • TEDS

Specifications

Measuring Range
Strain Gages and Strain-gage Transducers Quarter-bridge 120Ω System : Correspondence       
Half-bridge 120-1000Ω Active-active System : Correspondence       
Full-bridge 120-1000Ω System : Correspondence       
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Bridge Excitation Approx. 2 VDC for constant-voltage bridge excitation
Measuring Range 0 to ± 300 k ×10-6 strain(Constant-voltage bridge excitation)
Resolution 0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain
Accuracy 0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (At 12 VDC)
Operation: 100 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 55 D mm (Excluding protrusions)
Weight Approx. 310 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
screwdriver
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

Dimensions

NTB-100B-120

NTB-100B-350
Constant-voltage, One-touch terminal, 350Ω

NTB-100B-350
  • TEDS

Specifications

Measuring Range
Strain Gages and Strain-gage Transducers Quarter-bridge 350Ω System : Correspondence
Half-bridge 120-1000Ω Active-active System : Correspondence       
Full-bridge 120-1000Ω System : Correspondence       
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Bridge Excitation Approx. 2 VDC for constant-voltage bridge excitation
Measuring Range 0 to ± 300 k ×10-6 strain(Constant-current bridge excitation)
Resolution 0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain
Accuracy 0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (At 12 VDC)
Operation: 100 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 55 D mm (Excluding protrusions)
Weight Approx. 310 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
screwdriver
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

Dimensions

NTB-100B

NTB-101A-120
Constant-voltage, Screw soldering terminal, 120Ω

  • TEDS

Specifications

Measuring Range
Strain Gages and Strain-gage Transducers Quarter-bridge 120Ω System : Correspondence       
Half-bridge 120-1000Ω Active-active System : Correspondence       
Full-bridge 120-1000Ω System : Correspondence       
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Bridge Excitation Approx. 2 VDC
Measuring Range 0 to ± 300 k ×10-6 strain
Resolution 0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain
Accuracy 0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption At 12 VDC
Operation: 100 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 110 D mm (Excluding protrusions)
Weight Approx. 650 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
terminal block
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

Dimensions

NTB-101A

NTB-101A-350
Constant-voltage, Screw soldering terminal, 350Ω

  • TEDS

Specifications

Measuring Range
Strain Gages and Strain-gage Transducers Quarter-bridge 350Ω System : Correspondence  
Half-bridge 120-1000Ω Active-active System : Correspondence       
Full-bridge 120-1000Ω System : Correspondence       
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Bridge Excitation Approx. 2 VDC
Measuring Range 0 to ± 300 k ×10-6 strain
Resolution 0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain
Accuracy 0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption At 12 VDC
Operation: 100 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 110 D mm (Excluding protrusions)
Weight Approx. 650 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
terminal block
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

Dimensions

NTB-101A

NTB-110B-350
Constant-current, One-touch terminal, For Full bridge only

NTB-110B-350
  • TEDS

Specifications

Measuring Range
Civil Engineering Transducers Civil engineering transducers Full bridge 350 Ω Full bridge : Correspondence
Civil engineering transducers Full bridge 350 Ω Civil engineering transducer with thermal sensors : Correspondence
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Approx. 1 s/channel: With civil engineering transducers with a thermal sensor
Bridge Excitation Approx. 5.6 mA (At bridge resistance 350 Ω)
Measuring Range Strain measurement
0 to ± 30 k ×10-6 strain (Constant-current bridge excitation)

Temperature measurement with civil engineering transducers with a thermal sensor
-30.0 to 70.0°C
Resolution Strain measurement
0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain

Temperature measurement with civil engineering transducers with a thermal sensor
0.1°C
Accuracy Strain measurement
0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain

Temperature measurement with civil engineering
transducers with a thermal sensor:
± 0.5°C
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (At 12 VDC)
Operation: 70 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 55 D mm (Excluding protrusions)
Weight Approx. 310 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
screwdriver
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

NTB-111A-350
Constant-current, Screw soldering terminal, For Full bridge only

NTB-111A-350
  • TEDS

Specifications

Measuring Range
Civil Engineering Transducers Civil engineering transducers Full bridge 350 Ω Full bridge : Correspondence
Civil engineering transducers Full bridge 350 Ω Civil engineering transducer with thermal sensors : Correspondence
Channels 4
Scanning Speed Approx. 0.5 s/channel: 0 to ± 30 k ×10-6 strain
Approx. 1 s/channel: ± 30 k ×10-6 strain or more
Approx. 1 s/channel: With civil engineering transducers with a thermal sensor
Bridge Excitation Approx. 5.6 mA (At bridge resistance 350 Ω)
Measuring Range Strain measurement
0 to ± 30 k ×10-6 strain (Constant-current bridge excitation)

Temperature measurement with civil engineering transducers with a thermal sensor
-30.0 to 70.0°C
Resolution Strain measurement
0 to ± 30 k ×10-6 strain: 1 ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: 10 ×10-6 strain

Temperature measurement with civil engineering transducers with a thermal sensor
0.1°C
Accuracy Strain measurement
0 to ± 30 k ×10-6 strain: ± (0.05% of reading + 2) ×10-6 strain
± 30 k to ± 300 k ×10-6 strain: ± (0.1% of reading + 20) ×10-6 strain

Temperature measurement with civil engineering transducers with a thermal sensor:
± 0.5°C
TEDS Reads information from TEDS-installed sensors.
Channel name writing (Kyowa ID only)
Power Save Mode Provided ON/OFF using “OPT.3” DIP switch.
Interfaces Dedicated interface conforming to CAN, cable extension up to 1 km
Operating Temperature -10 to 50 °C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (At 12 VDC)
Operation: 70 mA or less
Standby: 60 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W × 28 H × 110 D mm (Excluding protrusions)
Weight Approx. 650 g
Standard Accessories DC power cable P-76, ground wire P-72,
wire connection seals, rubber feet,
terminal block
control software (NTB-10A), instruction manual (CD-R)
Optional Accessories Y cable N-103 (10 cm)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)
*Please contact us for communication cables other than those listed above.
AC adapter SA-10A-EDS
(100 to 240 VAC) (For U.S.A.: UNI318-1215-EDS)
Connection board/clip CN-1A
DIN rail mounting plate
Terminal resistor CANTERM 120
USB/CAN converter LEAF LIGHT HS V2

NTB-201A
DC Voltage-output, Thermocouples

Specifications

Channels 4
Scanning Speed Approx. 0.5 s/channel
Measuring Targets DC voltage-output, thermocouples
Voltage-output Measurement Range 10 V
Measuring range: 0 to ±10.0000 V
Resolution: 100 μV
Accuracy: ±(0.1% of reading +0.0003 V)
Input resistance: Approx. 1 MΩ

Range 50 V
Measuring range: 0 to ±50.000 V
Resolution: 1 mV
Accuracy: ±(0.1% of reading +0.003 V)
Input resistance: Approx. 1 MΩ
Thermocouples Type K
Measuring range: -200.0 to 1230.0°C
-200.0 to below -100°C: Accuracy is ±(0.2% of reading +0.3°C)
-100.0 to 1230.0°C: Accuracy is ±(0.1% of reading +0.2°C)
Resolution: 0.1 ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.

Type T
Measuring range: -200.0 to 400.0°C
-200.0 to below -100 °C: Accuracy is ±(0.2% of reading +0.3°C)
-100.0 to 400.0 °C: Accuracy is ±(0.1% of reading +0.2°C)
Resolution: 0.1 ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.

Type E
Measuring range: -200.0 to 660.0°C
-200.0 to below -100 °C: Accuracy is ±(0.2% of reading +0.3°C)
-200.0 to 660.0 ºC: Accuracy is ±(0.1% of reading +0.2°C)
Resolution: 0.1 ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.

Type J
Measuring range: -200.0 to 870.0°C
-200.0 to below -100 °C: Accuracy is ±(0.2% of reading +0.3°C)
-200.0 to 870.0 ºC: Accuracy is ±(0.1% of reading +0.2°C)
Resolution: 0.1 ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.

Type R
Measuring range: 0.0 to 1760.0°C
0.0 to below 100°C: Accuracy is ±(0.2% of reading +0.8°C)
100.0 to 1760.0°C: Accuracy is ±(0.125% of reading +0.6°C)
Resolution: 0.1ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.

Type N
Measuring range: -200.0 to 1300.0°C
-200.0 to below -100°C: Accuracy is ±(0.2% of reading +0.3°C)
-100.0 to 1300.0°C: Accuracy is ±(0.1% of reading +0.2°C)
Resolution: 0.1ºC
* Accuracy of Internal Reference-junction Compensator
Within ±0.5 ºC, when temperature balanced at input terminals, and the ambient temperature is 0 to 50 ºC.
Within ±1.0 ºC, when temperature balanced at input terminals, and the ambient temperature is -10 to 0 ºC.
Notes
1 . Accuracies do not include the internal reference junction compensator accuracy.
2. The reference junction compensator is witchable between internal and external.
3. The thermocouple resistance should be 1 kΩ or less.
Check Functions Burnout check
Power Save Mode Provided ON/OFF using “OPT.3" DIP switch
Interfaces Dedicated interface conforming to CAN
Operating Temperature -10 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (At 12 VDC)
Operation: 100 mA or less
Standby (In power save mode): 40 mA or less
Dimensions 150 W x 28 H x 55 D mm (Excluding protrusions)
Weight Approx. 320 g
Standard Accessories DC power cable P-76
Ground wire P-72

Dimensions

NTB-201A

NTB-20A
NTB power supply box

Specifications

NTB Series Connected Units and Cable Length With USB port
NTB series connected units: 1, Cable length: 200 m or less
NTB series connected units: 2, Cable length: 100 m or less

When AC adapter or DC power supply used
NTB series connected units: 1, Cable length: 1000 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 2, Cable length: 840 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 3, Cable length: 560 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 4, Cable length: 470 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 5, Cable length: 330 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 6, Cable length: 280 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 7, Cable length: 240 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 8, Cable length: 200 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 9, Cable length: 180 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 10, Cable length: 160 m or less (AC adapter When SA-10A-EDS used When UIA-345-12 used)
NTB series connected units: 11, Cable length: 150 m or less (AC adapter When UIA-345-12 used)
NTB series connected units: 12, Cable length: 130 m or less (AC adapter When UIA-345-12 used)
NTB series connected units: 13, Cable length: 120 m or less (AC adapter When UIA-345-12 used)
NTB series connected units: 14, Cable length: 120 m or less (AC adapter When UIA-345-12 used)
NTB series connected units: 15, Cable length: 110 m or less (AC adapter When UIA-345-12 used)
NTB series connected units: 16, Cable length: 100 m or less (AC adapter When UIA-345-12 used)
Power Save Functions Provided
In POWER switch "AUTO" mode (*1)
(*1) In "AUTO" mode, turning off the PC power supply automatically turns OFF the power supply to the NTB-20A (NTB power supply box).
When using "AUTO" mode, ensure that the PC and NTB-20A (NTB
power supply box) are connected using a USB cable.
Operating Temperature -10 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Power Supply Input USB port: 5 VDC
External power supply: 11 to 16 VDC
(AC adapter, DC power supply)
Current Consumption When using 12 VDC (Using AC adapter)
OFF mode: 7.0 mA or less
AUTO mode: 7.0 mA
ON mode: 30.0 mA or less
When using 5 VDC (Using USB port)
OFF mode: 5.0 mA or less
AUTO mode: 30.0 mA or less
ON mode: 30.0 mA or less
Dimensions 150 W x 28 H x 55 D mm (Excluding protrusions)
Weight Approx. 260 g
Optional Accessories Connection cable N-38 (1 m), N-39 (2 m)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)

Dimensions

NTB-20A

NTB-21A
NTB relay box

Specifications

Power supply output limitation function When power supply exceeding the range is input into NTB, the power supply output from the serial connector is turned to OFF.
Input Voltage Range 11 to 16 VDC
Operating Temperature -10 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Dimensions 150 W x 28 H x 29 D mm (Excluding protrusions)
Weight Approx. 160 g

Dimensions

NTB-21A

NTB-10A
Network terminal box control software

NTB-10A

Specifications

Measuring Units NTB-100 series: 1 to 99 (Max. 396 channels)
Measuring Functions RELATIVE measurement (Relative value measurement): Each value is obtained by subtracting the ZERO value.
*ZERO value is equivalent to the initial unbalance value.
Capable of obtaining the ZERO value at arbitrary timing
Channels Conditions Meas* channel ON/OFF, CAL coefficient calculation ON/OFF, CAL coefficient, Offset, Unit, Dec. digits, Ref resist, CH Name (20 characters)
*: Here "Meas" stands for measuring.
Measuring Condition File Load and save
Measuring Operations MONITOR Meas (Measure ZERO value during
MONITOR measurement) INTERVAL Meas
Interval Measurement Interval start time, interval time, repeat 0 to 9999
(0 to infinite)
Interval measuring steps: 5
Numeric Display Available windows: 1
Window switch: List only
Graph Display Y-time: Max. 8 channels/graph
BAR graph: Max. 32 channels/graph
Measured Data Saving Function The measured data is saved with the CSV format
TEDS Reads sensor's information and sets to channel condition automatically.
Channel name writing (Within 28 characters)
Data File Destination PC hard disk
File Split No split
Split every hour
Split every day
System Environment
CPU Core2Duo, 2 GHz or advanced
OS Windows® Vista, 7, 8, or 8.1(English/Japanese 32, 64 bits support)
Memory If 32-bit OS, 2 GB or more
If 64-bit OS, 4 GB or more
Display 1024×768 pixels or more
USB/CAN Converter Model: LEAFLIGHT HS V2

Page Top

Download