NTB-500C
Medium Speed Network Terminal Box

  • CE
  • TEDS

NTB-500C

Summary

· CAN interface
· Measurement of large strain (300 k ×10-6 strain)
· Strain, voltage, and thermocouple units provided

Features

The NTB-500C is a compact & lightweight data logger, which can synchronous measurement of all channels at a max. 1k Hz.
8 units synchronously for up to 64 channels connecting by one wire for decentralized arrangement is possible.

Products table

All display

NTB-500C
Medium Speed Network Terminal Box

NTB-500C
  • CE
  • TEDS

Specifications

Models NTB-500C, control software DCS-100A (Standard accessory)
NTB-500C-0, control software DCS-100A (Optional accessory)
Mountable Measuring Units [Model: NTB-50C]
 Name: Strain Unit
 Terminal block type: One-touch type

[Model: NTB-51C]
 Name: Voltage/Thermocouple Unit
 Terminal block type: Soldering, screwing type
Measuring Targets and Measuring Units [Strain Unit NTB-50C]
 Strain gages, strain-gage transducers
 Quarter bridge 120 Ω 2-wire system
 Quarter bridge 120 Ω 3-wire system
 Half bridge 120 to 1000 Ω Active-active system
 Full bridge 120 to 1000 Ω

[Voltage/Thermocouple Unit NTB-51C]
 Voltage ±10.0000 V
 Voltage ±50.000 V
 Temperature Thermocouples K(CA)
 Temperature Thermocouples T(CC)

*You are not able to combine with the NTB-50A, NTB-50B, NTB-51A.
Channels Max. 8/unit
Mixed combination of up to 2 measuring units (4 channels/unit) possible
Synchronous Operation Max. 8 units, 64 channels
The NTB-500C can connect with the NTB-500A.
Automated Measurement Functions Able to preset the measuring conditions by using the Measurement Condition Setting Software.
Able to output the CAN data after turning ON the power.
There is no data synchronization between measuring instruments.
Sampling Frequencies 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 Hz
Synchronous sampling of all channels.

Sampling frequencies (Hz): 1 k
 Cable length = 20 m: 8
 Cable length = 80 m: 4
 Cable length = 100 m: ー
 Cable length = 400 m: ー

Sampling frequencies (Hz): 500
 Cable length = 20 m: 16
 Cable length = 80 m: 8
 Cable length = 100 m: 4
 Cable length = 400 m: ー

Sampling frequencies (Hz): 200
 Cable length = 20 m: 40
 Cable length = 80 m: 20
 Cable length = 100 m: 8
 Cable length = 400 m: 4

Sampling frequencies (Hz): 100
 Cable length = 20 m: 64
 Cable length = 80 m: 40
 Cable length = 100 m: 20
 Cable length = 400 m: 8

Sampling frequencies (Hz): 50
 Cable length = 20 m: 64
 Cable length = 80 m: 64
 Cable length = 100 m: 40
 Cable length = 400 m: 20

Sampling frequencies (Hz): 20 to 1
 Cable length = 20 m: 64
 Cable length = 80 m: 64
 Cable length = 100 m: 64
 Cable length = 400 m: 64

*Make sure the firmware version is 01.05 or later for using the communication cable length 400 m.
Cable Length Total extended cable length, max. 400 m
TEDS When NTB-50C installed
Reads information from TEDS-installed sensors.
Channel name writing (If the manufacturer's ID is Kyowa)
Interfaces Bosch 2.0B active support
(ISO-11898 specifications-compliant high-speed CAN)
Data Save Measurement data is saved on a PC.
(No internal storage)
Operating Temperature -10 to 50 ºC
Operating Humidity 20 to 85% (Non-condensing)
Power Supply 11 to 16 VDC
Current Consumption (When using 12 VDC) [With 2 NTB-50C installed]
 Stand-by: 200 mA or less
 Measuring: 230 mA or less

[With 2 NTB-51C installed]
 Stand-by: 250 mA or less
 Measuring: 300 mA or less
Dimensions 175 W × 28.7 H × 106.4 D mm (Excluding protrusions)
Weight Approx. 490 g
Compliance Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)
Standard Accessories DC power cable P-76
Ground wire P-72
NTB-500A/C dummy panel (NTB500-DUMMY)*
 * NTB-500A/C dummy panel is mounted on a vacant slot before shipment.
Wire connection seal
Rubber feet × 4
Driver holder (With a mini screwdriver) × 1 set
Simplified software
Driver for a USB/CAN converter
DVD (Dynamic Data Acquisition Software DCS-100A) **
 ** For NTB-500C, standard accessory.
  For NTB-500C-0, optional accessory.
Instruction manual
Optional Accessories NTB-500A/C sync communications cable N-119 (1 m)
 Note: Please contact us if other than the cable lengths above
are required.
NTB-500A/C sync Y-cable N-120 (One side 0.1 m)
Connection cable N-38 (1 m)
AC adapter SA-10A-EDS (100 to 240 VAC)
 (For U.S.A.: UNI318-1215-EDS)
Strain Unit NTB-50C
Voltage/Thermocouple Unit NTB-51C
Docking board for 2 boxes of NTB-500A/C
 CN-10A: For connecting 2 boxes of NTB-500A/C
Docking board for 4 boxes of NTB-500A/C
 CN-11A: For connecting 4 boxes of NTB-500A/C
NTB-500A/C dummy panel NTB500-DUMMY
DIN rail mounting plate
DIN rail (35 mm)
Terminal resistor CANTERM120
USB/CAN converter LEAFLIGHT HS V2
Data analysis software DAS-200A
NTB power supply box NTB-20A

Dimensions

NTB-500C

NTB-50C
Strain Unit

NTB-50C
  • CE
  • TEDS

Specifications

Terminal Block One-touch type
Channels 4
Measuring Targets Strain gages
Strain-gage transducers
Compatible Bridge Resistance Quarter-bridge 120 Ω (2-wire, 3-wire)
Half-bridge, Full-bridge 120 to 1000 Ω
Gage Factor 2.00 fixed
Bridge Excitation 2 VDC ±1%
Check Functions Cable disconnection check
TEDS Reads information from TEDS-installed sensors.
Channel name writing (If the manufacturer's ID is Kyowa)
Measuring Range, Resolution, Range Accuracy Measuring range: 30 k ×10-6 strain
Resolution: 0.1 ×10-6 strain
Range accuracy: ±0.1%FS

Measuring range: 300 k ×10-6 strain
Resolution: 1 ×10-6 strain
Range accuracy: ±0.1%FS
Response Frequencies DC to 100 Hz (Deviation +1 dB, -3 dB)
Dimensions 152.2 W × 6.1 H × 45 D mm (Excluding protrusions)
Weight Approx. 85 g
Compliance Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)

NTB-51C
Voltage/Thermocouple Unit

NTB-51C
  • CE

Specifications

Terminal Block Screw-soldering type
Channels 4
Measuring Targets Voltage
Thermocouples (K, T)
Check Functions Burnout check
TEDS N/A
At voltage measurement [Measuring range: 10 V]
 Resolution: 100 μV
 Range accuracy: ±0.1%FS
 Input resistance: Approx. 1 MΩ

[Measuring range: 50 V]
 Resolution: 1 mV
 Accuracy: ±0.1%FS
 Input resistance: Approx. 1 MΩ
At thermocouple measurement [Type: K]
Measuring range: -200.0 to 1230.0°C
Accuracy
External standard junction: ±(0.5% of reading+1.0)°C
Internal standard junction range, temp. (25 ±10)°C:
 ±(0.5% of reading +2.0)°C (At input terminal temp. balance)
Resolution: 0.1°C

[Type: T]
Measuring range: -200.0 to 400.0 °C
Accuracy
External standard junction: ±(0.5% of reading+1.0)°C
Internal standard junction range, temp. (25 ±10)°C:
 ±(0.5% of reading +2.0)°C (At input terminal temp. balance)
Resolution: 0.1°C

Notes:
* Accuracy doesn't include the accuracy of the thermocouple.
* Switching between internal and external standard junction compensator is possible.
* Thermocouple resistance 1 kΩ or less
Response Frequencies At voltage measurement: DC to 100 Hz (Deviation +1 dB, -3 dB)
At thermocouple measurement: DC to 10 Hz (Deviation +0.5 dB, -1 dB)
Isolation Between channels: 50 MΩ or more (500 VDC)
Dimensions 152.2 W × 6.1 H × 45 D mm (Excluding protrusions)
Weight Approx. 95 g
Compliance Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)

AC Adapter

SA-10A-EDS
AC Adapter

SA-10A-EDS
Object Product Model TPS-A
NTB-500A
NTB-100/200 series
EDS-400A
Remarks For U.S.A.: Use UNI318-1215-EDS.

UNI318-1215-EDS
AC Adapter

UNI318-1215-EDS
Object Product Model NTB-500A
NTB-100/200 series
EDS-400A
ERK-101A
MRS-111A
TPS-A
Remarks For U.S.A.

NTB-20A
NTB power supply box

Power Save Function (AUTO Mode) When the PC power supply is OFF, then the power supply of the NTB-20 connected by a USB cable is off.
Power Supply Output Limitation Function When a power supply exceeding the power supply range for operating the NTB-20A is input, for safety, the power supply output from the serial connector and the OUT connector is turned OFF.

Specifications

NTB Series Connected Units and Cable Length [With USB port]
NTB series connected units: 1, Cable length: 200 m or less
NTB series connected units: 2, Cable length: 100 m or less

[When AC adapter or DC power supply used]
NTB series connected units: 1, Cable length: 1000 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 2, Cable length: 840 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 3, Cable length: 560 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 4, Cable length: 470 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 5, Cable length: 330 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 6, Cable length: 280 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 7, Cable length: 240 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 8, Cable length: 200 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 9, Cable length: 180 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 10, Cable length: 160 m or less
(When SA-10A-EDS or UIA345-12 used)

NTB series connected units: 11, Cable length: 150 m or less
(When UIA345-12 used)

NTB series connected units: 12, Cable length: 130 m or less
(When UIA345-12 used)

NTB series connected units: 13, Cable length: 120 m or less
(When UIA345-12 used)

NTB series connected units: 14, Cable length: 120 m or less
(When UIA345-12 used)

NTB series connected units: 15, Cable length: 110 m or less
(When UIA345-12 used)

NTB series connected units: 16, Cable length: 100 m or less
(When UIA345-12 used)
Power Save Functions Provided
In POWER switch "AUTO" mode (*1)

(*1) In "AUTO" mode, turning off the PC power supply automatically turns OFF the power supply to the NTB-20A (NTB power supply box).
When using "AUTO" mode, ensure that the PC and NTB-20A (NTB power supply box) are connected using a USB cable.
Operating Temperature -10 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Power Supply Input USB port: 5 VDC
External power supply: 11 to 16 VDC (AC adapter, DC power supply)
Current Consumption When using 12 VDC (Using AC adapter)
OFF mode: 7.0 mA or less
AUTO mode: 7.0 mA
ON mode: 30.0 mA or less

When using 5 VDC (Using USB port)
OFF mode: 5.0 mA or less
AUTO mode: 30.0 mA or less
ON mode: 30.0 mA or less
Dimensions 150 W x 28 H x 55 D mm (Excluding protrusions)
Weight Approx. 260 g
Optional Accessories Connection cable N-38 (1 m), N-39 (2 m)
Communication cable N-102 (1 m)
Communication cable H-11681 (3 m)
Communication cable H-11682 ( 5 m)
Communication cable H-11683 (10 m)

Dimensions

NTB-20A

LEAF LIGHT HS V2
USB/CAN Converter

LEAF LIGHT HS V2
Object Product Model NTB-100/200 series
NTB-500C

CANTERM 120
Terminal Resistor

CANTERM 120
Object Product Model NTB-100/200 series
NTB-500C

NTB500-DUMMY
Dummy Panel

NTB500-DUMMY
Object Product Model NTB-500C

Page Top

Remarks

* NTB-500C(-0) can not be used with NTB-50A/B or NTB-51A.
* NTB-50C and NTB-51C cannot be used with NTB-500A(-0).

eBook

Download