UCAM-60C M14, UCAM-65C M14
Data Logger

  • TEDS

UCAM-60C/65C

Summary

・Saving the long-term saving measured results to the built-in memory (Approx. 1.8 GB)
・USB memory ensures easy data collection
・Up to 1000 channels measurement
 (With external scanners USB-70B series)
・Measurement up to 20000 ×10-6 strain with a resolution of 0.1 ×10-6 strain (With full bridge system)
・All-in-one measuring instrument (UCAM-60C M14)
・Online data logger fully controlled from the PC (UCAM-65C M14)

Features

The data logger UCAM-60C M14 is an all-in-one measuring instrument developed in full pursuit of easier field measurement.
It has easy-to-operate keys, a bright readable display providing understandable presentation and a printer for immediate confirmation of measurement results.

Contents

【Data Loggers】
UCAM-60C-AC M14 (AC, UCS-60B: Optional, operation keys, built-in display, printer)
UCAM-60C-DC M14 (DC, UCS-60B: Optional, operation keys, built-in display, printer)
UCAM-65C-AC M14 (AC, UCS-60B: Standard, PC-controlled)
UCAM-65C-AC-0 M14 (AC, UCS-60B: Optional, PC-controlled)
UCAM-65C-DC M14 (DC, UCS-60B: Standard, PC-controlled)
UCAM-65C-DC-0 M14 (DC, UCS-60B: Optional, PC-controlled)

【Dedicated Scanners (Optional) 】
USS-61B (TEDS compatible) *
 The dedicated scanner measures 10 channels/unit.
 The main unit accommodates up to 3 dedicated scanners.
USS-62B (With NDIS4102 (7 pins) connectors, TEDS compatible) *
 The dedicated scanner measures 10 channels/unit.
 The main unit accommodates up to 3 dedicated scanners.
USS-63B (For civil engineering, with lightning arresters, TEDS compatible) *
 The dedicated scanner measures 10 channels/unit.
 The main unit accommodates up to 3 dedicated scanners.

* TEDS compatible function is made effective by connecting TEDS installed sensor through NDIS4102 (7 pins) connector.

【External Scanners】
The main unit is connected to the following scanners via the optional scanner interface.
USB-70B (Via scanner interface USI-67A)

【Scanner Interfaces 】
USI-67A for USB-70B

【External I/O Unit】
UIO-60A

【Control Software】
UCS-60B

Products table

All display

UCAM-60C M14
Data Logger

UCAM-60C
  • TEDS

Specifications

Measuring Targets Strain gages
Strain-gage transducers
DC voltage-output instruments
DC current-output instruments
Civil engineering transducers with a thermal sensor
Potentiometer sensors
Thermal sensors (Thermocouples and platinum resistance thermometer bulbs)
Connectable Scanners USS-61B, USS-62B, USS-63B
(Dedicated scanners, mounted on top of the UCAM-60C M14)

The main unit is connected to the following scanners via the optional scanner interface (USI-67A).
USB-70B series (via USI-67A)
Channels Max. 30 with dedicated scanners
Max. 1000 with external scanners connected
Max. 1000 with dedicated scanners and external scanners connected
Input Terminals Can connect to lead wires through either soldering or screwing.
(Screw: M3 with metal plate)

NDIS4102 (7 pins) connectors (USS-62B)
Switching Terminal Semiconductor relays
Scanning Speed 50 ms/channel (Standard mode)
0.28 s/channel (High-resolution mode)
20 ms/channel (High-speed mode)

-------Scanners--------------------Line Frequencies------------
Dedicated scanner (Standard mode)
           50 Hz Zone: 50 ms/channel
           60 Hz Zone: 50 ms/channel
Dedicated scanner (High-resolution mode)
           50 Hz Zone: 0.28 s/channel
           60 Hz Zone: 0.28 s/channel
Dedicated scanner (High-speed mode)
           50 Hz Zone: 20 ms/channel
           60 Hz Zone: 20 ms/channel
USB-70B (Standard mode only)
           50 Hz Zone: 60 ms/channel
           60 Hz Zone: 58.4 ms/channel

[Note 1]
Scanning speeds stated above are standard maximum speeds in respective modes.
Besides these, the following speeds are set for each individual channel:
 0.28 s, 0.5 s, 1 s, 2 s, 5 s, and 10 s.

[Note 2]
High-resolution mode and high-speed mode are selectable for dedicated scanners only.

[Note 3]
High-resolution mode is individually switchable for desired channels.
High-speed mode is only collective switching for all channels of dedicated scanners.
Repeat measurement interval time
 = (Number of Measuring channels × scanning speed)
 + data processing time (2 to 20 s)
*Data processing time is indeterminate, changed by measurement setting and environment.


-------Measuring Targets--------------------Scanning Speed------------
Strain (Gage & transducer)
      Standard Mode (50 ms/channel)
      High-resolution Mode (0.28 s/channel)
      High-speed Mode (20 ms/channel)
Voltage/current-output sensor
      Standard Mode (50 ms/channel)
      High-speed Mode (20 ms/channel)
Civil engineering transducer
      Standard Mode (50 ms/channel)
Temperature sensor (TC, Pt)
      Standard Mode (50 ms/channel)
Potentiometer sensor
      Standard Mode (50 ms/channel)
      High-speed Mode (20 ms/channel)

[Note 1]
High-resolution mode is available only with full bridge system.
[Note 2]
High-speed mode is available full bridge system, voltage, current, and potentiometer sensor.
Operating Modes Real-time
Monitor
Automatic (Interval measurement)
Measurement Functions Initial (Initial values are measured and stored in internal memory.)
Measure (Initial values are subtracted from original values.)
Original (Raw values are measured without subtraction of initial values.)
Easy Measure (Auto zero balancing function is activated.)

*The selected function is applied to all channels.
Coefficient Calculation Function Multiplication by calibration coefficient
Calibration by TEDS
Conversion of measured values to physical quantities
Scaling
Correction
Unit 59 units
Automatic Measurement Function
Interval Measurement Measurement is automatically performed at preset time intervals.
Trigger Measurement A relative value (certain changing quantity) or an absolute value triggers measurement.
Trigger Interval Measurement Combination of trigger measurement and interval measurement.
Storage Internal memory
Capacity: Approx. 1.8 GB
Strain Measurement (Standard Mode)
Constant Voltage Excitation Approx. 2 or 5 VDC
Constant Current Excitation Approx. 5.7 mA (Bridge resistance 350 Ω)
Approx. 16.7 mA (Bridge resistance 120 Ω)
Scanning Speed 50 ms/channel
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Initial Value Memory Range Same as measuring range.
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±50 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.05% of reading +1) ×10-6 strain

Measuring Range: ±50 k to ±500 k ×10-6 strain
Resolution: 10 ×10-6 strain
Accuracy: ±(0.05% of reading +10) ×10-6 strain

*Resolution and accuracy be automatically changed by Autorange function.
Strain Measurement (High-resolution Mode)
Constant Voltage Excitation Approx. 5 VDC
Constant Current Excitation Approx. 16.7 mA (Bridge resistance 350 Ω)
Scanning Speed 0.28 s/channel
Initial Value Memory Range Same as measuring range.
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±20 k ×10-6 strain
Resolution: 0.1 ×10-6 strain
Accuracy: ±(0.05% of reading +0.3) ×10-6 strain

Measuring Range: ±20 k to ±200 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.05% of reading +3) ×10-6 strain

Note 1: Available only with full bridges system.
Note 2: Bridge resistance should be 120 to 1000 Ω for bridge excitation with constant voltage.
Note 3: Bridge resistance should be 350 Ω for bridge excitation with constant current.
 [Measuring range]
 0 to ±15000 ×10-6 strain
 0 to ±150000 ×10-6 strain
Note 4: Available only with dedicated scanners.
Note 5: Resolution and accuracy be automatically changed by Autorange function.
Strain Measurement (High-speed Mode)
Constant Voltage Excitation Approx. 2 VDC
Constant Current Excitation Approx. 5.7mA (Bridge resistance 350 Ω)
Approx. 16.7mA (Bridge resistance 120 Ω)
Scanning Speed 20 ms/channel
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Initial Value Memory Range Same as measuring range.
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±50 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.08% of reading +3) ×10-6 strain

Measuring Range: ±50 k to ±500 k ×10-6 strain
Resolution: 10 ×10-6 strain
Accuracy: ±(0.08% of reading +30) ×10-6 strain

[Note 1]
Available only with full bridges system (120 to 1000 Ω).
[Note 2]
Available only with dedicated scanners.
[Note 3]
Resolution and accuracy be automatically changed by Autorange function.
Voltage Measurement (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: V/500mV
Measuring Range: 0 to ±50.000 mV
Resolution: 1 μV
Accuracy: ±(0.05% of reading +0.003) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/500mV
Measuring Range: ±50.00 to ±500.00 mV
Resolution: 10 μV
Accuracy: ±(0.05% of reading +0.03) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/50V
Measuring Range: 0 to ±5.0000 V
Resolution: 100 μV
Accuracy: ±(0.05% of reading +0.0002) V
Input Resistance: 1 MΩ or more

Channel Mode: V/50V
Measuring Range: ±5.000 to ±50.000 V
Resolution: 1 mV
Accuracy: ±(0.05% of reading +0.002) V
Input Resistance: 1 MΩ or more

*Resolution and accuracy be automatically changed by Autorange function.
Voltage Measurement (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: V/500mV
Measuring Range: 0 to ±50.000 mV
Resolution: 1 μV
Accuracy: ±(0.08% of reading +0.006) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/500mV
Measuring Range: ±50.00 to ±500.00 mV
Resolution: 10 μV
Accuracy: ±(0.08% of reading +0.06) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/50V
Measuring Range: 0 to ±5.0000 V
Resolution: 100 μV
Accuracy: ±(0.08% of reading +0.0006) V
Input Resistance: 1 MΩ or more

Channel Mode: V/50V
Measuring Range: ±5.000 to ±50.000 V
Resolution: 1 mV
Accuracy: ±(0.08% of reading +0.006) V
Input Resistance: 1 MΩ or more

[Note 1]
Resolution and accuracy be automatically changed by Autorange function.
[Note 2]
Available only with dedicated scanners.
Current Measurement (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: I/50 mA
Measuring Range: 0 to ±50.00 mA
Resolution: 10 μA
Accuracy: ±(0.05% of reading +0.01) mA

[Note 1]
External shunt resistor (high-accuracy 250 Ω) is required.
[Note 2]
Stated accuracy does not include the resistance error of the external shunt resistor.
Current Measurement (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: I/50 mA
Measuring Range: 0 to ±50.00 mA
Resolution: 10 μA
Accuracy: ±(0.08% of reading +0.01) mA

[Note 1]
Available only with dedicated scanners.
[Note 2]
External shunt resistor (high-accuracy 250 Ω) is required.
[Note 3]
Stated accuracy does not include the resistance error of the external shunt resistor.
Temperature Measurement with Thermocouple (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy 【Type: K】
Measuring Range: −200.0 to 1230.0℃
Resolution: 0.1℃
Accuracy: ±0.7℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: T】
Measuring Range: −200.0 to 400.0℃
Resolution: 0.1℃
Accuracy: ±0.7℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: E】
Measuring Range: −200.0 to 660.0℃
Resolution: 0.1℃
Accuracy: ±0.5℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: J】
Measuring Range: −200.0 to 870.0℃
Resolution: 0.1℃
Accuracy: ±0.6℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: R】
Measuring Range: 0 to 1760.0℃
Resolution: 0.1℃
Accuracy: ±2.2℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

[Note 1]
Accuracies do not include the internal reference junction compensator accuracy.
[Note 2]
The reference junction compensator is switchable between internal and external.
[Note 3]
Thermocouple resistance should be 1 kΩ or less.
Temperature Measurement with Civil Engineering Transducers with a Thermal Sensor (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy Measuring Range: −50.0 to 200.0℃
Resolution: 0.1℃
Accuracy: ±0.5℃

[Note 1]
Target physical quantity and temperature are measured in a single channel.
[Note 2]
Strain measuring range are the same as in strain measurement in standard mode.
Temperature Measurement with Platinum Resistance Thermometer Bulb (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy 【Type: Pt100】
Measuring Range: −200.0 to 660.0℃
Resolution: 0.1℃
Accuracy: ±0.3℃

【Type: JPt100】
Measuring Range: −200.0 to 510.0℃
Resolution: 0.1℃
Accuracy: ±0.3℃

Note: Connection is 3-wire system.
Measurement with Potentiometer Sensor (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Sensor Power Supply Approx. 2 VDC
Potentiometer Resistance 1 kΩ to 10 kΩ
Measuring Range, Resolution and Accuracy Channel Mode: POT.
Measuring Range: 0 to ±50.00%
Resolution: 0.01%
Accuracy: ±0.1% FS
Measurement with Potentiometer Sensor (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Sensor Power Supply Approx. 2 VDC
Potentiometer Resistance 1 kΩ to 10 kΩ
Measuring Range, Resolution and Accuracy Channel Mode: POT.
Measuring Range: 0 to ±50.00%
Resolution: 0.01%
Accuracy: ±0.1% FS

Note: Available only with dedicated scanners.
Internal Timer Real time clock is built-in. (Battery backup)
Display Fluorescent display tube
128 × 64 dots
Printer Printing: Thermal
Paper width: 58 mm (24 characters/line)
Printing speed: 60 mm/s (Max.)
Interface RS-232C
LAN (10BASE-T/100BASE-TX)
USB2.0 (Collects measurement data by USB Flash Drive.)

*1: Measurement data cannot be saved directly to USB memory.
*2: USB Flash Drives
 Capacity: 32 GB or less
 File Format: FAT32
*3: Recommend USB Flash Drives: GH-UFI-XSD2G
 (Manufacturer: GREENHOUSE)
File Conversion Binary measurement data can be converted to CSV.
Self Diagnosis Functions Checks display, printer, bridge excitation, leadwire-off, input/output resistance, insulation resistance, mode, etc.
TEDS [Interface]
IEEE1451.4 Mixed Mode Transducer Interface Class2

[Applicable sensor]
 Should have information written in accordance with IEEE template No.33.
 Cable length should be 30m or less.

*With dedicated scanner USS-61B/62B/63B.
Operating Temperature 0 to 50ºC
Operating Humidity 20% to 85% (Non-condensing)
Storage Temperature -20 to 60ºC
Setting Maintenance Function ACOM at measurement circuit is switchable between floating and GND connect.
Power Supply 100 to 240 VAC (AC-operated version)

10 to 16 VDC (DC-operated version)
*DC operated version has power control function.
Current Consumption 100 VAC: 0.5 A or less (With 3 dedicated scanners mounted)
12 VDC: 4.0 A or less (With 3 dedicated scanners mounted)
Dimensions 360 W ×88 H ×400 D mm (Excluding protrusions)
Weight Approx. 6.3 kg (Excluding scanner)
Approx. 9.6 kg (With 3 dedicated scanners USS-62B mounted)
Standard Accessories AC power cable P-18 (With 2-pin conversion plug CM-52)
 (AC-operated version)
DC power cable P-76
 (DC-operated version)
Recording paper UCAM-60A-RP (1 roll)
Screwdriver
Spare fuse
CD-R (Instruction Manual)
Ground wire P-72
Optional Accessories Recording paper UCAM-60A-RP (10 rolls/pack)

Dimensions

UCAM-60C

UCAM-65C M14
Data Logger

UCAM-65C
  • TEDS

Specifications

Measuring Targets Strain gages
Strain-gage transducers
DC voltage-output instruments
DC current-output instruments
Civil engineering transducers with a thermal sensor
Potentiometer sensors
Thermal sensors (Thermocouples and platinum resistance thermometer bulbs)
Connectable Scanners USS-61B, USS-62B, USS-63B
(Dedicated scanners, mounted on top of the UCAM-60C M14)

The main unit is connected to the following scanners via the optional scanner interface (USI-67A).
USB-70B series (via USI-67A)
Channels Max. 30 with dedicated scanners
Max. 1000 with external scanners connected
Max. 1000 with dedicated scanners and external scanners connected
Input Terminals Can connect to lead wires through either soldering or screwing.
 (Screw: M3 with metal plate)

NDIS4102 (7 pins) connectors (USS-62B)
Switching Terminal Semiconductor relays
Scanning Speed 50 ms/channel (Standard mode)
0.28 s/channel (High-resolution mode)
20 ms/channel (High-speed mode)

-------Scanners--------------------Line Frequencies------------
Dedicated scanner (Standard mode)
           50 Hz Zone: 50 ms/channel
           60 Hz Zone: 50 ms/channel
Dedicated scanner (High-resolution mode)
           50 Hz Zone: 0.28 s/channel
           60 Hz Zone: 0.28 s/channel
Dedicated scanner (High-speed mode)
           50 Hz Zone: 20 ms/channel
           60 Hz Zone: 20 ms/channel
USB-70B (Standard mode only)
           50 Hz Zone: 60 ms/channel
           60 Hz Zone: 58.4 ms/channel

[Note 1]
Scanning speeds stated above are standard maximum speeds in respective modes.
Besides these, the following speeds are set for each individual channel:
 0.28 s, 0.5 s, 1 s, 2 s, 5 s, and 10 s.

[Note 2]
High-resolution mode and high-speed mode are selectable for dedicated scanners only.

[Note 3]
High-resolution mode is individually switchable for desired channels.
High-speed mode is only collective switching for all channels of dedicated scanners.
Repeat measurement interval time
 = (Number of Measuring channels × scanning speed)
 + data processing time (2 to 20 s)
*Data processing time is indeterminate, changed by measurement setting and environment.


-------Measuring Targets--------------------Scanning Speed------------
Strain (Gage & transducer)
      Standard Mode (50 ms/channel)
      High-resolution Mode (0.28 s/channel)
      High-speed Mode (20 ms/channel)
Voltage/current-output sensor
      Standard Mode (50 ms/channel)
      High-speed Mode (20 ms/channel)
Civil engineering transducer
      Standard Mode (50 ms/channel)
Temperature sensor (TC, Pt)
      Standard Mode (50 ms/channel)
Potentiometer sensor
      Standard Mode (50 ms/channel)
      High-speed Mode (20 ms/channel)

[Note 1]
High-resolution mode is available only with full bridge system.
[Note 2]
High-speed mode is available full bridge system, voltage, current, and potentiometer sensor.
Operating Modes Real-time
Monitor
Automatic (Interval measurement)
Measurement Functions Initial (Initial values are measured and stored in internal memory.)
Measure (Initial values are subtracted from original values.)
Original (Raw values are measured without subtraction of initial values.)
Easy Measure (Auto zero balancing function is activated.)

*The selected function is applied to all channels.
Coefficient Calculation Function Multiplication by calibration coefficient
Calibration by TEDS
Conversion of measured values to physical quantities
Scaling
Correction
Unit 59 units
Automatic Measurement Function
Interval Measurement Measurement is automatically performed at preset time intervals.
Trigger Measurement A relative value (certain changing quantity) or an absolute value triggers measurement.
Trigger Interval Measurement Combination of trigger measurement and interval measurement.
Storage Internal memory
Capacity: Approx. 1.8 GB
Strain Measurement (Standard Mode)
Constant Voltage Excitation Approx. 2 or 5 VDC
Constant Current Excitation Approx. 5.7 mA (Bridge resistance 350 Ω)
Approx. 16.7 mA (Bridge resistance 120 Ω)
Scanning Speed 50 ms/channel
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±50 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.05% of reading +1) ×10-6 strain

Measuring Range: ±50 k to ±500 k ×10-6 strain
Resolution: 10 ×10-6 strain
Accuracy: ±(0.05% of reading +10) ×10-6 strain

*Resolution and accuracy be automatically changed by Autorange function.
Strain Measurement (High-resolution Mode)
Constant Voltage Excitation Approx. 5 VDC
Constant Current Excitation Approx. 16.7 mA (Bridge resistance 350 Ω)
Scanning Speed 0.28 s/channel
Initial Value Memory Range Same as measuring range.
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±20 k ×10-6 strain
Resolution: 0.1 ×10-6 strain
Accuracy: ±(0.05% of reading +0.3) ×10-6 strain

Measuring Range: ±20 k to ±200 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.05% of reading +3) ×10-6 strain

Note 1: Available only with full bridges system.
Note 2: Bridge resistance should be 120 to 1000 Ω for bridge excitation with constant voltage.
Note 3: Bridge resistance should be 350 Ω for bridge excitation with constant current.
 [Measuring range]
 0 to ±15000 ×10-6 strain
 0 to ±150000 ×10-6 strain
Note 4: Available only with dedicated scanners.
Note 5: Resolution and accuracy be automatically changed by Autorange function.
Strain Measurement (High-speed Mode)
Constant Voltage Excitation Approx. 2 VDC
Constant Current Excitation Approx. 5.7mA (Bridge resistance 350 Ω)
Approx. 16.7mA (Bridge resistance 120 Ω)
Scanning Speed 20 ms/channel
Gage Factor 2.00 fixed
(Coefficient calculation function enables correction with 2.00/Ks.)
Initial Value Memory Range Same as measuring range.
Measuring Range, Resolution and Accuracy Measuring Range: 0 to ±50 k ×10-6 strain
Resolution: 1 ×10-6 strain
Accuracy: ±(0.08% of reading +3) ×10-6 strain

Measuring Range: ±50 k to ±500 k ×10-6 strain
Resolution: 10 ×10-6 strain
Accuracy: ±(0.08% of reading +30) ×10-6 strain

[Note 1]
Available only with full bridges system (120 to 1000 Ω).
[Note 2]
Available only with dedicated scanners.
[Note 3]
Resolution and accuracy be automatically changed by Autorange function.
Voltage Measurement (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: V/500mV
Measuring Range: 0 to ±50.000 mV
Resolution: 1 μV
Accuracy: ±(0.05% of reading +0.003) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/500mV
Measuring Range: ±50.00 to ±500.00 mV
Resolution: 10 μV
Accuracy: ±(0.05% of reading +0.03) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/50V
Measuring Range: 0 to ±5.0000 V
Resolution: 100 μV
Accuracy: ±(0.05% of reading +0.0002) V
Input Resistance: 1 MΩ or more

Channel Mode: V/50V
Measuring Range: ±5.000 to ±50.000 V
Resolution: 1 mV
Accuracy: ±(0.05% of reading +0.002) V
Input Resistance: 1 MΩ or more

*Resolution and accuracy be automatically changed by Autorange function.
Voltage Measurement (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: V/500mV
Measuring Range: 0 to ±50.000 mV
Resolution: 1 μV
Accuracy: ±(0.08% of reading +0.006) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/500mV
Measuring Range: ±50.00 to ±500.00 mV
Resolution: 10 μV
Accuracy: ±(0.08% of reading +0.06) mV
Input Resistance: 10 MΩ or more

Channel Mode: V/50V
Measuring Range: 0 to ±5.0000 V
Resolution: 100 μV
Accuracy: ±(0.08% of reading +0.0006) V
Input Resistance: 1 MΩ or more

Channel Mode: V/50V
Measuring Range: ±5.000 to ±50.000 V
Resolution: 1 mV
Accuracy: ±(0.08% of reading +0.006) V
Input Resistance: 1 MΩ or more

[Note 1]
Resolution and accuracy be automatically changed by Autorange function.
[Note 2]
Available only with dedicated scanners.
Current Measurement (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: I/50 mA
Measuring Range: 0 to ±50.00 mA
Resolution: 10 μA
Accuracy: ±(0.05% of reading +0.01) mA

[Note 1]
External shunt resistor (high-accuracy 250 Ω) is required.
[Note 2]
Stated accuracy does not include the resistance error of the external shunt resistor.
Current Measurement (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Measuring Range, Resolution and Accuracy Channel Mode: I/50 mA
Measuring Range: 0 to ±50.00 mA
Resolution: 10 μA
Accuracy: ±(0.08% of reading +0.01) mA

[Note 1]
Available only with dedicated scanners.
[Note 2]
External shunt resistor (high-accuracy 250 Ω) is required.
[Note 3]
Stated accuracy does not include the resistance error of the external shunt resistor.
Temperature Measurement with Thermocouple (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy 【Type: K】
Measuring Range: −200.0 to 1230.0℃
Resolution: 0.1℃
Accuracy: ±0.7℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: T】
Measuring Range: −200.0 to 400.0℃
Resolution: 0.1℃
Accuracy: ±0.7℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: E】
Measuring Range: −200.0 to 660.0℃
Resolution: 0.1℃
Accuracy: ±0.5℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: J】
Measuring Range: −200.0 to 870.0℃
Resolution: 0.1℃
Accuracy: ±0.6℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

【Type: R】
Measuring Range: 0 to 1760.0℃
Resolution: 0.1℃
Accuracy: ±2.2℃
Internal Reference Junction Compensator Accuracy: ±0.5℃
 (With input terminal temperature balanced in an ambient)
 (Temp. range of 0 to 50°C)

[Note 1]
Accuracies do not include the internal reference junction compensator accuracy.
[Note 2]
The reference junction compensator is switchable between internal and external.
[Note 3]
Thermocouple resistance should be 1 kΩ or less.
Temperature Measurement with Civil Engineering Transducers with a Thermal Sensor (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy Measuring Range: −50.0 to 200.0℃
Resolution: 0.1℃
Accuracy: ±0.5℃

[Note 1]
Target physical quantity and temperature are measured in a single channel.
[Note 2]
Strain measuring range are the same as in strain measurement in standard mode.
Temperature Measurement with Platinum Resistance Thermometer Bulb (Standard Mode)
Scanning Speed 50 ms/channel
Measuring Range, Resolution and Accuracy 【Type: Pt100】
Measuring Range: −200.0 to 660.0℃
Resolution: 0.1℃
Accuracy: ±0.3℃

【Type: JPt100】
Measuring Range: −200.0 to 510.0℃
Resolution: 0.1℃
Accuracy: ±0.3℃

Note: Connection is 3-wire system.
Measurement with Potentiometer Sensor (Standard Mode)
Scanning Speed 50 ms/channel
Initial Value Memory Range Same as measuring range
Sensor Power Supply Approx. 2 VDC
Potentiometer Resistance 1 kΩ to 10 kΩ
Measuring Range, Resolution and Accuracy Channel Mode: POT.
Measuring Range: 0 to ±50.00%
Resolution: 0.01%
Accuracy: ±0.1% FS
Measurement with Potentiometer Sensor (High-speed Mode)
Scanning Speed 20 ms/channel
Initial Value Memory Range Same as measuring range
Sensor Power Supply Approx. 2 VDC
Potentiometer Resistance 1 kΩ to 10 kΩ
Measuring Range, Resolution and Accuracy Channel Mode: POT.
Measuring Range: 0 to ±50.00%
Resolution: 0.01%
Accuracy: ±0.1% FS

Note: Available only with dedicated scanners.
Internal Timer Real time clock is built-in. (Battery backup)
Interface RS-232C
LAN (10BASE-T/100BASE-TX)
USB2.0 (Collects measurement data by USB Flash Drive.)

*1: Measurement data cannot be saved directly to USB memory.
*2: USB Flash Drives
 Capacity: 32 GB or less
 File Format: FAT32
*3: Recommend USB Flash Drives: GH-UFI-XSD2G
 (Manufacturer: GREENHOUSE)
Self Diagnosis Functions Checks bridge excitation, leadwire-off, input/output resistance, insulation resistance, mode, etc.
TEDS [Interface]
IEEE1451.4 Mixed Mode Transducer Interface Class2

[Applicable sensor]
 Should have information written in accordance with IEEE template No.33.
 Cable length should be 30m or less.

*With dedicated scanner USS-61B/62B/63B.
Operating Temperature 0 to 50ºC
Operating Humidity 20% to 85% (Non-condensing)
Storage Temperature -20 to 60ºC
Setting Maintenance Function ACOM at measurement circuit is switchable between floating and GND connect.
Power Supply 100 to 240 VAC (AC-operated version)

10 to 16 VDC (DC-operated version)
*DC operated version has power control function.
Current Consumption 100 VAC: 0.5 A or less (With 3 dedicated scanners mounted)
12 VDC: 4.0 A or less (With 3 dedicated scanners mounted)
Dimensions 327 W ×88 H ×365 D mm (Excluding protrusions)
Weight Approx. 5.0 kg (Excluding scanners)
Approx. 8.3 kg (With 3 dedicated scanners USS-62B mounted)
Standard Accessories AC power cable P-18 (With 2-pin conversion plug CM-52)
 (AC-operated version)
DC power cable P-76
 (DC-operated version)
Screwdriver
Spare fuse
CD-R (Instruction Manual)
CD-R (Control software UCS-60B)
Ground wire P-72

Dimensions

UCAM-65C

USS-61B
Dedicated Scanner (TEDS compatible)

USS-61B
  • TEDS

Specifications

Model TEDS compatible
Channels 10/unit
Switching Terminals Semiconductor relays
Input Terminals Connect to lead wire by either soldering or screwing.
One-touch terminal block (JT-1A) (Optional)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 80% (Non-condensing)
Dimensions 320 W x 28 H x 80 D mm (Excluding protrusions)
Weight Approx. 0.8 kg
Standard Accessories Terminal cover
Channel label
Short bar ML-1000-3H1

USS-62B
Dedicated Scanner (With NDIS4102 (7 pins) connectors, TEDS compatible)

USS-62B
  • TEDS

Specifications

Model With NDIS4102 (7 pins) connectors, TEDS compatible
Channels 10/unit
Switching Terminals Semiconductor relays
Input Terminals Connect to lead wire by either soldering or screwing.
NDIS4102 (7 pins) connectors
One-touch terminal block (JT-1A) (Optional)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 80% (Non-condensing)
Dimensions 320 W x 28 H x 80 D mm (Excluding protrusions)
Weight Approx. 1.1 kg
Standard Accessories NDIS4102 (7 pins) connector caps (Pre-attached to connectors)
Terminal cover
Channel label
Short bar ML-1000-3H1

USS-63B
Dedicated Scanner (For civil engineering measurement, TEDS compatible, with lightning arresters)

USS-63B
  • TEDS

Specifications

Model For civil engineering measurement, TEDS compatible, with lightning arresters
Channels 10/unit
Switching Terminals Semiconductor relays
Input Terminals Connect to lead wire by either soldering or screwing.
One-touch terminal block (JT-1A) (Optional)
Lightning Arresters Built in USS-63B
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 80% (Non-condensing)
Dimensions 320 W x 28 H x 80 D mm (Excluding protrusions)
Weight Approx. 1.0 kg
Standard Accessories Terminal cover
Channel label
Short bar ML-1000-3H1

USI-67A
Scanner Interfaces

Specifications

Connectable Scanners USB-70B
Number of Scanners Max. 20
Cable Length Max. 1 km
(When connecting the UPS-70B to the USB-70B.)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 85% (Non-condensing)
Dimensions 99 W x 50 H x 163 D mm (Excluding protrusions)
Weight Approx. 170 g

UIO-60A
External I/O Unit

UIO-60A

Specifications

Output
ALARM Signal 4 channels (High/low limit checking)
BUSY Signal 1 channel
Input
START Signal 1 channel
STOP Signal 1 channel
RESET Signal 1 channel
RAINFALL Signals 1 channel
Operating Temperature 0 to 50 ºC
Operating Humidity 20 to 85% (Non-condensing)
Dimensions 90 W x 50 H x 180 D mm (Excluding protrusions)
Weight Approx. 140 g
Standard Accessories Screwdriver

USB-70B-10
External Scanner (For general measurement)

USB-70B-10

Specifications

Models USB-70B-10 (For general measurement)
Measuring Targets Strain gages
Strain-gage transducers
DC voltage 0 to ±50 V
DC current 0 to ±50 mA
Thermocouples K, T, E, J, N, B, S, R
Potentiometer sensors
Channels 50/unit
Connection Data Loggers UCAM-60C M14
UCAM-65C M14

*An optional Scanner Interface USI-67A is required.
Number of Connection Up to 20

*19 if there are 30 channels in the data logger
Input Terminals Screw-soldering terminal blocks (M3 screw with washer)

[Receptacle] PRC90-231BR10-7F
[Applicable plug] ex. PRC03-12A10-7M10.5
Switching Elements Semiconductor relays
Measuring Mode Every channel set by the data logger
Measuring Channel Number The upper 2-digit from every 10 channels are set with digital switches
Power Supply Supplied from data logger.

If the cable is extended or if 4 or more scanners are connected, an optional UPS-70B should be mounted into the scanners.
Dimensions 302 W x 107 H x 500 D mm
(Excluding protrusions)
Weight Approx. 7.3 kg
(Excluding UPS-70B)
Option Built-in AC Power Unit UPS-70B
100 to 240 VAC
(100 to 127 VAC or 220 to 240 VAC automatic switchover)
Standard Accessories Phillips precision screwdriver
Connection cable N-24 (1 m)

USB-70B-20
External Scanner (For general measurement, with NDIS4102 (7 pins) connectors)

Specifications

Models USB-70B-20 (For general measurement, with NDIS4102 (7 pins) connectors)
Measuring Targets Strain gages
Strain-gage transducers
DC voltage 0 to ±50 V
DC current 0 to ±50 mA
Thermocouples K, T, E, J, N, B, S, R
Potentiometer sensor
Channels 50/unit
Connection Data Loggers UCAM-60C M14
UCAM-65C M14

*An optional Scanner Interface USI-67A is required.
Number of Connection Up to 20

*19 if there are 30 channels in the data logger
Input Terminals Screw-soldering terminal blocks (M3 screw with washer)
NDIS4102 (7 pins) connectors

[Receptacle] PRC90-231BR10-7F
[Applicable plug] ex. PRC03-12A10-7M10.5
Switching Elements Semiconductor relays
Measuring Modes Every channel set by the data logger
Measuring Channel Number The upper 2-digit from every 10 channels are set with digital switches
Power Supply Supplied from data logger.

If the cable is extended or if 4 or more scanners are connected, an optional UPS-70B should be mounted into the scanners.
Dimensions 302 W x 107 H x 500 D mm
(Excluding protrusions)
Weight Approx. 8.5 kg
(Excluding UPS-70B)
Option Built-in AC Power Unit UPS-70B
100 to 240 VAC
(100 to 127 VAC or 220 to 240 VAC automatic switchover)
Standard Accessories Phillips precision screwdriver
Connection cable N-24 (1 m)

USB-70B-30
External Scanner (For civil engineering)

USB-70B

Specifications

Model USB-70B-30 (For civil engineering)
Measuring Targets Strain gages
Strain-gage transducers
DC voltage 0 to ±50 V
DC current 0 to ±50 mA
Thermocouples K, T, E, J, N, B, S, R
Platinum resistance thermometer bulbs Pt100, JPt100
Civil engineering transducers with a thermal sensor
Potentiometer sensor
Channels 50/unit
Connection Data Loggers UCAM-60C M14
UCAM-65C M14

*An optional Scanner Interface USI-67A is required.
Number of Connection Up to 20

*19 if there are 30 channels in the data logger
Input Terminals Screw-soldering terminal blocks (M3 screw with washer)

[Receptacle] PRC90-231BR10-7F
[Applicable plug] ex. PRC03-12A10-7M10.5

Built-in lightning arresters
Switching Elements Semiconductor relays
Measuring Mode Every channel set by the data logger
Measuring Channel Number The upper 2-digit from every 10 channels are set with digital switches
Power Supply Supplied from data logger.

If the cable is extended or if 4 or more scanners are connected, an optional UPS-70B should be mounted into the scanners.
Dimensions 302 W x 107 H x 500 D mm
(Excluding protrusions)
Weight Approx. 7.7 kg
(Excluding UPS-70B)
Option Built-in AC Power Unit UPS-70B
100 to 240 VAC
(100 to 127 VAC or 220 to 240 VAC automatic switchover)
Standard Accessories Phillips precision screwdriver
Connection cable N-24 (1 m)

Page Top