WGA-120A
Carrier Type Instrumentation Amplifier

WGA-120A

Summary

· Strong against inverter noise.
· Output of voltage or current is switchable

Features

The WGA-120A is a Carrier Type Instrumentation Amplifier, which is suitable for connecting a strain-gage transducer to measure loads, pressure, torques or displacements.

Products table

All display

WGA-120A
Carrier Type Instrumentation Amplifier

WGA-120A
Models [WGA-120A-00]
 Power Codes: DC
 Power Supply: 10.5 to 15 VDC
 Power Consumption: 3.5 W or less
 Balance Adjustment: Manual

[WGA-120A-01]
 Power Codes: 100 VAC
 Power Supply: 90 to 110 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-02]
 Power Codes: 200 VAC
 Power Supply: 180 to 220 VAC,
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-03]
 Power Codes: 240 VAC
 Power Supply: 216 to 264 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-10]
 Power Codes: DC
 Power Supply: 10.5 to 15 VDC
 Power Consumption: 3.5 W or less
 Balance Adjustment: Automatic

[WGA-120A-11]
 Power Codes: 100 VAC
 Power Supply: 90 to 110 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic

[WGA-120A-12]
 Power Codes: 200 VAC
 Power Supply: 180 to 220 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic

[WGA-120A-13]
 Power Codes: 240 VAC
 Power Supply: 216 to 264 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic

Specifications

Channels 1
Applicable Transducers Strain-gage transducers
Compatible Bridge Resistance 87.5 to 1000 Ω (Up to four 350 Ω transducers connected in parallel.
Bridge excitation is limited to 2 or 1 Vrms for transducers with bridge resistance less than 175 Ω.)
Bridge Excitation 5, 2, 1 Vrms, square wave
(Switchable by changing internal jumper connection)
Input Range [Sensitivity Switch ×2000]
Bridge Excitation(Vrms):1
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±5 to ±12.5
Bridge Excitation(Vrms):2
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±2.5 to ±6.25
Bridge Excitation(Vrms):5
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±1 to ±2.5

[Sensitivity Switch ×4000]
Bridge Excitation(Vrms):1
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±2.5 to ±6.25
Bridge Excitation(Vrms):2
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±0.5 to ±1.25
Bridge Excitation(Vrms):5
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±0.5 to ±1.25

[Sensitivity Switch ×10000]
Bridge Excitation(Vrms):1
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±1 to ±2.5
Bridge Excitation(Vrms):2
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±2.5 to ±6.25
Bridge Excitation(Vrms):5
Input Range (mV/V)Sensitivity Adjustment×1 to ×0.4:±0.2 to ±0.5
Rated Output Voltage: ±10 V (Load resistance: 2 k Ω or more)
Current: 4 to 20 mA (Load resistance: 500 Ω or less, voltage output: 0 to 10 V)
(Switchable by changing internal jumper connection)
Zero Adjustment Range Within ±1.5 mV/V, manual balance or auto balance by selecting model.
Sensitivity Adjustment Range ×2000, ×4000, ×10000
 (Switchable by changing internal jumper connection)
Adjustable between ×0.4 and ×1.0 by the trimmer.
Calibration Calibration by the parallel resistance method
0.25 mV/V or 0.05 mV/V at 350 Ω bridge resistance
(Switchable by changing internal jumper connection)
Frequency Response 10, 30, 100, or 500 Hz (Switchable by changing internal jumper connection)
Nonlinearity Within ±0.1%FS
SN Ratio 53dB p-p or more

[Conditions]
Sensitive: ×10000, ×0.5 (Adjustment by the trimmer)
Frequency response: 500 Hz
Bridge resistance: 120 Ω
Bridge excitation: 2 Vrms
Stability Temperature
Zero point: Within ±0.2μVRTI /°C
Sensitivity: Within ±0.05%/°C

Time
Zero point: Within ±0.5μVRTI /8h
Sensitivity: Within ±0.2%/8h

[Conditions]
Sensitive: ×10000, ×1.0 (Adjustment by the trimmer)
Bridge resistance: 120 Ω
Bridge excitation: 2 Vrms
Operating Temperature -10 to 50°C
Operating Humidity 20 to 85% (Non-condensing)
Power Supply [WGA-120A-00]
 Power Codes: DC
 Power Supply: 10.5 to 15 VDC
 Power Consumption: 3.5 W or less
 Balance Adjustment: Manual

[WGA-120A-01]
 Power Codes: 100 VAC
 Power Supply: 90 to 110 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-02]
 Power Codes: 200 VAC
 Power Supply: 180 to 220 VAC,
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-03]
 Power Codes: 240 VAC
 Power Supply: 216 to 264 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Manual

[WGA-120A-10]
 Power Codes: DC
 Power Supply: 10.5 to 15 VDC
 Power Consumption: 3.5 W or less
 Balance Adjustment: Automatic (Also possible with external contact)

[WGA-120A-11]
 Power Codes: 100 VAC
 Power Supply: 90 to 110 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic (Also possible with external contact)

[WGA-120A-12]
 Power Codes: 200 VAC
 Power Supply: 180 to 220 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic (Also possible with external contact)

[WGA-120A-13]
 Power Codes: 240 VAC
 Power Supply: 216 to 264 VAC
 Power Consumption: 6.5 VA or less
 Balance Adjustment: Automatic (Also possible with external contact)
Dimensions 44 W × 90 H ×80 D mm (Excluding protrusions)
Weight DC power supply model: Approx. 350g
AC power supply model: Approx. 450g
Panel-cut Dimensions 45×93.4 mm
Standard Accessories Instruction manual
Optional Accessories AC power cable
P-23 (For 100 VAC)
P-28 (For 200/240 VAC)
DIN rail mounting fixture EDP-70

Dimensions

WGA-120A

AC power cables

P-23
2-pin plug to 2 conductors, crimp-style terminal (M3)

Specifications

Length Approx. 2.0 m
Object Product Model WGA-100B, 101A, 120A, 200A, 650B, 680A, 710C, 910A
WGC-140A
WGI-400A
Others For 100 VAC

P-28
3 round-shape terminals to 3 conductors, pre-soldering at the cable tip

P-28

Specifications

Length Approx. 2.0 m
Object Product Model WGA-100B, 101A, 120A, 200A, 650B, 680A, 710C, 910A
WGC-140A
WGI-400A
Others For 200 VAC

EDP-70
DIN Rail Mounting Fixture

EDP-70
Object Product Model WGA-120A

Page Top

eBook