DIS-5200A
Data Logger for Crash Test

  • TEDS

DIS-5200A

Summary

DIS-5200A is designed to record dummy qualification data, component test data, etc.

It can be connected to various sensors: strain gages, strain gage type transducers, piezoresistive transducers, voltage-output sensors, potentmeter type transducers.
Data from sensors are amplifiered, A/D converted and saved to large volum memory.

Features

●8 channels/unit
●Large-capacity flash memory (can save 75 seconds of data sampled at 10 kHz)
●LAN (Ethernet) 100BASE-TX interface
●It enables measurement of signals of foil/semiconductor strain gages, strain-gage transducers and voltage-output sensors as well as digital signals.
●PC controlled

Products table

All display

DIS-5200A
Data Logger for Crash Test

DIS-5200A
  • TEDS

General specifications

Operating Temperature 0 to 50°C
Operating Humidity 10 to 80%RH (Non-condensing)
Power Supply 100 to 240 VAC
Dimensions 327 W x 44 H x 180 D mm (Excluding protrusions)
Weight 2 kg or less

Individual specifications

Analog Input
Number of Channels 8
Input Connector ECG.1B.307 (Applicable plug: FGG. 1B.307 LEMO made)
Input Format Balance differential input
Input Resistance Bridge sensor measurement: Approx. (10 + 10 MΩ)
Voltage measurement: Approx. (100 + 100 kΩ)
Input Voltage ±20 V
Gain × 0.1 to 0.9 (× 0.1 step)
× 1 to 5000 (× 1 step)
Gain Accuracy Within ±0.2 % FS
Balanced Adjustment Gain
×0.1 to 0.9 : ±10 V
×1 to 19 : ±1 V
×20 to 99 : ±50 mV
×100 to 5000 : ±10 mV
Others Input short-circuit function
(For eliminating offset voltage)
Bridge Power Supply
Voltage Apply Method Each channel on/off switchable.
Bridge Excitation 10, 5, 2 VDC, and OFF
Bridge Configuration Half or full bridge system
Bridge Resistance 120 Ω to 5 kΩ
Accuracy Within ±0.1%
Maximum Current Within 30 mA
LPF
Fixed Filters SAE standard. Conforming to CFC1000
(ISO6487-2002/SAEJ211-1-2007)
Overshoot 5% or less
Variable Filters Transfer characteristics: 5th order Butterworth
Cutoff frequency: 50, 100, 200, 400, 1 k, 2 k, 4 k,10 k, and 20 k Hz
Amplitude ratio: -3 ±2 dB
Attenuation: -30 dB/oct.
A/D Conversion
Resolution 16 bits
Sampling Methods All channels symultaneously
Sampling Frequencies 100, 200, 500, 1 k, 2 k, 5 k, 10 k, 16 k, 20 k, 50 k, and 100 k Hz
S/N 50 dB or more (With fixed LPF)
Digital Input
Number of Channels 16
Measuring Targets Non-voltage contact
Input Formats Isolation input
Data Recording Section
Data Recording Memory 750 k words/channels, SRAM
(Saves data for 75 s at 10 kHz sampling)
Holding time: Approx. 3 h
(Backed up using a super capacitor when the power is turned off)
Data Storage Memory 64 MB flash memory
Triggers
External Triggers No-voltage contact inputs: 2 (Isolation input)
Trigger 1 and 2
Level Triggers Operated by level of arbitrary 3 channels.
Cascade Triggers Operated by trigger output between units or triggers output of conventional device.
Software Triggers Operated by command issued from the external PC.
The software trigger detects the event above and records the data before and after.
Synchronous Connection
Cable Connection Max. 16 units are connected by cables
TEDS Functions IEEE-1451.4 compatible
(Mixed Mode Transducer interface Class 2)
Read (All areas) and write (Only a user area)
Interfaces Conforming to 100BASE-TX
Indicators
LED Status display LED: Ready for trigger, triggered, error, and overflow
LED Monitor Displays DIS-5210A status in 8 alphanumeric.
Check Functions Sensor check, wire break check, gain check, excitation voltage check, memory check
Log Functions Records the operation log in the DIS-5200A.

Page Top

Remarks

Model of test measuring system in automotive crash test changed from "DIS-5200AS1" to "DIS-5200A".