On-vehicle High Voltage Data Logger for Crash Test

Summary

This logger has 980.7m/s2 (100G) impact resistance, and can safely measure the high voltage signals such as those of batteries used in electric and hybrid vehicles.
Between input channels are insulated, therefore this can safely measure the high voltages of batteries used in electric and hybrid vehicles during crash tests.
There are two measurement methods. One is unit acquisition mode (maximum 20kHz sampling) that records within the logger data which is recovered after testing, and the other is PC acquisition mode (maximum 100Hz sampling) that transmits and saves data on a connected PC in real time. This means that unit acquisition mode can be used during crash tests, and PC acquisition mode can be used during voltage monitoring and other preparations.

Features

●Measurement range ±500VDC/±250VDC
●At sampling frequency 20kHz, measurement for approximately 62 seconds, and at 100Hz, for approximately 8 hours (PC acquisition mode).
●Real-time measurement possible (sampling frequency 100Hz or less)
●Frequency characteristics are DC to 1kHz
●Measurement: 3 channels
●Maximum sampling frequency 20kHz
●nput level display LED built-in
●Use of 100BASE-TX for high-speed data transmission possible

Products table

All display

DIV-503A
On-vehicle High Voltage Data Logger for Crash Test

Total specifications

Triggers No voltage connection or TTL signal
Interfaces 10BASE-T, 100BASE-TX
Impact Resistance 980.7 m2 (100 G) 10 ms half sine
X, Y, Z axis directions: each1000 times
Withstand Voltage 1000Vrms (Leakage current 100 μA or less)
(Between each input, input-case, input-output)
Operating Temperature 0 to 50ºC
Operating Humidity 20 to 80% RH (Non-condensing)
Built-in Batteries Type: Nickel-hydride
Recharging time: Approx. 3.5 h
Operating time: Approx. 30 min
Power Supply 11 to 15 VDC
Consumption current: 2.0 A or less
Weight Approx. 2.5 kg

Insulated Section Specifications

Number of Channels 3
Input Signals Voltage
Input Range Automatic selection using the provided cable
±500 VDC or 250 VDC
(Safe input: Max. 1000 V)
Input Impedance 10 + 10 MΩ

A/D transducer specifications

Resolution 16 bits
Sampling Simultaneous sampling of all channels
Measuring Modes DIV acquisition mode
 Data stored internally, data collection after testing
PC acquisition mode
 Direct transfer of data to PC
Sampling Frequencies DIV acquisition mode
 1, 2, 5, 10, 20, 50, 100, 200, 500,
 1 k, 2 k, 5 k, 10 k, and 20 k Hz
PC acquisition mode
 1, 2, 5, 10, 20, 50, 100 Hz

Control Software Specifications

OS Windows Vista®, Windows® 7 (32-bit, 64-bit)
Interfaces 10BASE-T, 100BASE-TX
Setting Functions Sampling frequency, measuring mode
and channel name
Display Functions Time series graph

Dimensions

DIV-503A

Page Top

Download