Wheel 6-component Force Measuring System

Keyvisual

Summary

This syatem enables measurement of 3 forces (Fx, Fy, Fz) acting on 3 orthogonal axes to the running axle at the wheel mounting part and 3 moments (Mx, My, Mz) around the axes.
The wheel itself is made to act as the sensor to detect the 6-component force and output signals are transmitted by the slip-ring to the 6-component signal processor.

Features

●Thin and lightweight sensor
●The sensor ensures easy handling.
●Single 6-component signal processor supports four wheels.
 A high-speed DSP improves the processing capability.
●Dedicated signal processor contains an indicator which is easy to view in the field with a user-friendly remote controller.

Contents

●6-component sensor
●Slip-ring unit
●6-component signal processor
●Data logger
●Data process/analysis software

Products table

All display

Wheel 6-component Force Measuring System

picture

Specifications

Performance
Rated Capacity [Load]
Fx (Longitudinal force): ±30kN
Fy (Lateral force): ±25kN
Fz (Load or reactive force of load): ±30kN

[Moment]
Mx (Overturning moment): ±6kN・m
My (Rplling resistance moment): ±8.5kN・m
Mz (Self-aligning moment): ±6kN・m
Rotation Speed 2000 rpm (wheel rotation speed)
Nonlinearity Within ±0.5% RO (based on static tests)
Hysteresis Within ±0.5% RO (based on static tests)
Interference Force → Force: ±1.0% RO
Force → Moment: ±0.5% RO
Momemt →Force: ±1.5% RO
Moment→ Moment: ±1.0% RO
(After correction by interference correction coefficient.)
Environmental Characteristics
Safe Temperature Sensor: -30 to 100°C
Hub: -30 to 130°C
Transmitter: -20 to 70°C
Processor: -20 to 60°C
Compensated Temperature Sensor: -20 to 80°C
Transmitter: -10 to 60°C
Processor: -10 to 50°C
Acceptable Hub Size PCD100 to 114.3, hub bolts (nuts) 4 or 5
Acceptable Rim Size 13 to 20 inches
(In order to avoid interference, please pay attention to shape of brake caliper.)
Electrical Characteristics
Power Supply 10 to 18 VDC or 100 to 240 VAC (with AC adapter)
Output Signal ±10 V (analog voltage output)
Mechanical Properties
Safe Overloads Force: 150%
Moment: 130%
Natural Frequencies Sensor: 1 kHz or more
Impact Resistant 686 m/s2 (70 G)
Fatigue Strength JIS D 4103
Degree of Protection Sensor: IP65 (IEC 60529)
Installation Using the hub adapter to install sensors.
Various PCD are applicable by changing wheel adapters.

Page Top