Pipe Stress Measuring System

Pipestress

Summary

This System is used to measure the stress exerted on pipes due to the vibration of compressors of air conditioning, etc.
The strain gages synchronously measure 16 points and perform record on the specified conditions.
Recording consists of bridge box, strain amplifier, PC,and control/analysis software, etc.

Features

Measuring the stress on pipe
●Measurement the pipe stress of air conditioning, etc.
●Dramatically reducing testing time
●Maximum measurable stress of 16 channels
●Maximum sampling frequency of 1kHz

Contents

· Universal recorder EDX-100A ×1
· PC ×1
· Dedicated software ×1
· Housing case ×1
*Optional models come with a printer.

Products table

All display

Pipe Stress Measuring System

Pipe Stress Measurement System

Specifications

Applicable Sensors 120 Ω strain gages
Number of Channels 16
Sampling Frequencies DC to 1 kHz±10%
Measuring Accuracy ±0.5% FS
Recording Start Mode The specified analog input (1 channel)
Level trigger
Recording Time 16 s (At sampling of 1 kHz)
Functions Data recording function
Stress display function
Waveform display function
FFT analysis function
Document output function
Others
Power Supply 100 to 240 VAC
Operating Temperature 10 to 35°C
Operating Humidity 30 to 80% RH (Non-condensing)