AMA-A
Small-sized Triaxial Accelerometer

AMA-A

Summary

The AMA-A is a compact & lightweight accelerometer with large overloads resistant.

Rated Capacity: ±19.61 to ±1961 m/s2

Features

• High frequency response
• Fault diagnosis function is available (AMA-A-2, 5)
• Battery box for AMA is also available as an optional accessory.

Products table

All display

AMA-A-2
±2 G

AMA-A

Specifications

Performance
Rated Capacity ±19.61 m/s2 (±2 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ±7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ±2.5 to ±6 VDC
Single supply: 5 to 12 VDC
Current Consumption 10 mA or less (At 5 VDC)
Cable 6-conductor (0.04 mm2) vinyl shielded cable, 2.5 mm diameter by 5 m long
(Shield wire is not connected to the case.)
(A relay cable (optional) is necessary for connecting measuring instruments.)
Mechanical Properties
Safe Overloads ±19613 m/s2 (±2000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 500 Hz
(Sensitivity deviation: ±10%)
Weight Approx. 3 g
Optional Accessories Relay cables TE-55, TE-56
Battery box for AMA

Dimensions

AMA-A

AMA-A-5
±5 G

AMA-A

Specifications

Performance
Rated Capacity ±49.03 m/s2 (±5 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ±7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ±2.5 to ±6 VDC
Single supply: 5 to 12 VDC
Current Consumption 10 mA or less (At 5 VDC)
Cable 6-conductor (0.04 mm2) vinyl shielded cable, 2.5 mm diameter by 5 m long
(Shield wire is not connected to the case.)
(A relay cable (optional) is necessary for connecting measuring instruments.)
Mechanical Properties
Safe Overloads ±19613 m/s2 (±2000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 500 Hz
(Sensitivity deviation: ±10%)
Weight Approx. 3 g
Optional Accessories Relay cables TE-55, TE-56
Battery box for AMA

Dimensions

AMA-A

AMA-A-100
±100 G

AMA-A-100

Specifications

Performance
Rated Capacity ±980.7 m/s2 (±100 G)
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ±7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ±2.5 to ±6 VDC
Single supply: 5 to 12 VDC
Current Consumption 20 mA or less (At 5 VDC)
Cable [1] Sensor - relay part
9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by 5 m long

[2] Relay part - connector
20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter by 17 cm long, terminated with a connector plug (HR25A-9J-20S)

(Shield wire is not connected to sensor case.)
(A relay cable (optional) is necessary for connecting measuring instruments.)
Mechanical Properties
Safe Overloads ±39227 m/s2 (±4000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 500 Hz (Sensitivity deviation: ±10%)
Weight Approx. 11 g
Optional Accessories Relay cable AMA-A-M-S2K
Battery box for AMA

Dimensions

AMA-A

AMA-A-200
±200 G

AMA-A-200

Specifications

Performance
Rated Capacity ±1961 m/s2 (±200 G)
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ±7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ±2.5 to ±6 VDC
Single supply: 5 to 12 VDC
Current Consumption 20 mA or less (At 5 VDC)
Cable [1] Sensor - relay part
9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by 5 m long

[2] Relay part - connector
20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter by 17 cm long, terminated with a connector plug (HR25A-9J-20S)

(Shield wire is not connected to the case.)
(A relay cable (optional) is necessary for connecting measuring instruments.)
Mechanical Properties
Safe Overloads ±39227 m/s2 (±4000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 500 Hz (Sensitivity deviation: ±10%)
Weight Approx. 11 g
Optional Accessories Relay cable AMA-A-M-S2K
Battery box for AMA

Dimensions

AMA-A

Page Top

Remarks

* When using the following items, an external power supply unit is not required.
* The acceleration transducer is subject to a constant acceleration in the direction of gravity, therefore measurement is restricted, taking into account this vertical movement (9.807 m/s2).

eBook

Download

Recommended products for combination