AMA-A
Small-sized Triaxial Accelerometer

Summary
The AMA-A is a compact & lightweight accelerometer with large overloads resistant.
Rated Capacity: ±19.61 to ±1961 m/s2
Features
• High frequency response
• Fault diagnosis function is available (AMA-A-2, 5)
• Battery box for AMA is also available as an optional accessory.
Products table
All display
AMA-A-2
±2 G

Specifications
Performance
Rated Capacity | ±19.61 m/s2 (±2 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 2 V ±10% |
Peak-to-peak Sensitivity Error | 4% RO or less |
Environmental Characteristics
Safe Temperature | -20 to 80ºC (Non-condensing) |
---|---|
Compensated Temperature | -10 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.5% RO/ºC |
Temperature Effect on Output | Within ±1%/ºC |
Electrostatic Withstand Voltage | 4 kV |
Electrical Characteristics
Safe Excitation | Dual supply: ±7 VDC Single supply: 14 VDC |
---|---|
Recommended Excitation | Dual supply: ±2.5 to ±6 VDC Single supply: 5 to 12 VDC |
Current Consumption | 10 mA or less (At 5 VDC) |
Cable | 6-conductor (0.04 mm2) vinyl shielded cable, 2.5 mm diameter by 5 m long (Shield wire is not connected to the case.) (A relay cable (optional) is necessary for connecting measuring instruments.) |
Mechanical Properties
Safe Overloads | ±19613 m/s2 (±2000 G) |
---|---|
Transverse Sensitivity | 4% RO or less |
Frequency Response | DC to 500 Hz (Sensitivity deviation: ±10%) |
Weight | Approx. 3 g |
Optional Accessories | Relay cables TE-55, TE-56 Battery box for AMA |
---|
Dimensions

AMA-A-5
±5 G

Specifications
Performance
Rated Capacity | ±49.03 m/s2 (±5 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 2 V ±10% |
Peak-to-peak Sensitivity Error | 4% RO or less |
Environmental Characteristics
Safe Temperature | -20 to 80ºC (Non-condensing) |
---|---|
Compensated Temperature | -10 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.5% RO/ºC |
Temperature Effect on Output | Within ±1%/ºC |
Electrostatic Withstand Voltage | 4 kV |
Electrical Characteristics
Safe Excitation | Dual supply: ±7 VDC Single supply: 14 VDC |
---|---|
Recommended Excitation | Dual supply: ±2.5 to ±6 VDC Single supply: 5 to 12 VDC |
Current Consumption | 10 mA or less (At 5 VDC) |
Cable | 6-conductor (0.04 mm2) vinyl shielded cable, 2.5 mm diameter by 5 m long (Shield wire is not connected to the case.) (A relay cable (optional) is necessary for connecting measuring instruments.) |
Mechanical Properties
Safe Overloads | ±19613 m/s2 (±2000 G) |
---|---|
Transverse Sensitivity | 4% RO or less |
Frequency Response | DC to 500 Hz (Sensitivity deviation: ±10%) |
Weight | Approx. 3 g |
Optional Accessories | Relay cables TE-55, TE-56 Battery box for AMA |
---|
Dimensions

AMA-A-100
±100 G

Specifications
Performance
Rated Capacity | ±980.7 m/s2 (±100 G) |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±1% RO |
Rated Output | 2 V ±10% |
Peak-to-peak Sensitivity Error | 4% RO or less |
Environmental Characteristics
Safe Temperature | -20 to 80ºC (Non-condensing) |
---|---|
Compensated Temperature | -10 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.5% RO/ºC |
Temperature Effect on Output | Within ±1%/ºC |
Electrostatic Withstand Voltage | 4 kV |
Electrical Characteristics
Safe Excitation | Dual supply: ±7 VDC Single supply: 14 VDC |
---|---|
Recommended Excitation | Dual supply: ±2.5 to ±6 VDC Single supply: 5 to 12 VDC |
Current Consumption | 20 mA or less (At 5 VDC) |
Cable | [1] Sensor - relay part 9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by 5 m long [2] Relay part - connector 20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter by 17 cm long, terminated with a connector plug (HR25A-9J-20S) (Shield wire is not connected to sensor case.) (A relay cable (optional) is necessary for connecting measuring instruments.) |
Mechanical Properties
Safe Overloads | ±39227 m/s2 (±4000 G) |
---|---|
Transverse Sensitivity | 4% RO or less |
Frequency Response | DC to 500 Hz (Sensitivity deviation: ±10%) |
Weight | Approx. 11 g |
Optional Accessories | Relay cable AMA-A-M-S2K Battery box for AMA |
---|
Dimensions

AMA-A-200
±200 G

Specifications
Performance
Rated Capacity | ±1961 m/s2 (±200 G) |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±1% RO |
Rated Output | 2 V ±10% |
Peak-to-peak Sensitivity Error | 4% RO or less |
Environmental Characteristics
Safe Temperature | -20 to 80ºC (Non-condensing) |
---|---|
Compensated Temperature | -10 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.5% RO/ºC |
Temperature Effect on Output | Within ±1%/ºC |
Electrostatic Withstand Voltage | 4 kV |
Electrical Characteristics
Safe Excitation | Dual supply: ±7 VDC Single supply: 14 VDC |
---|---|
Recommended Excitation | Dual supply: ±2.5 to ±6 VDC Single supply: 5 to 12 VDC |
Current Consumption | 20 mA or less (At 5 VDC) |
Cable | [1] Sensor - relay part 9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by 5 m long [2] Relay part - connector 20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter by 17 cm long, terminated with a connector plug (HR25A-9J-20S) (Shield wire is not connected to the case.) (A relay cable (optional) is necessary for connecting measuring instruments.) |
Mechanical Properties
Safe Overloads | ±39227 m/s2 (±4000 G) |
---|---|
Transverse Sensitivity | 4% RO or less |
Frequency Response | DC to 500 Hz (Sensitivity deviation: ±10%) |
Weight | Approx. 11 g |
Optional Accessories | Relay cable AMA-A-M-S2K Battery box for AMA |
---|
Dimensions

Remarks
* When using the following items, an external power supply unit is not required.
* The acceleration transducer is subject to a constant acceleration in the direction of gravity, therefore measurement is restricted, taking into account this vertical movement (9.807 m/s2).