AMAS-A
Small-sized Accelerometer

AMAS-A

Summary

Small & durable accelerometers
Rated Capacity: ±980.7 m/s2 to ±1961 m/s2
Dimensions: 15 W × 6.3 H × 11 D mm
Rated Output: 2 V ±20%
Frequency Response: DC to 2k Hz

Features

High frequency response
Safe overloads ±39227 m/s2 (±4000 G)
MEMS (Micro Electro Mechanical Systems)

Products table

All display

AMAS-A-100
±100 G

AMAS-A

Specifications

Performance
Rated Capacity ±980.7 m/s2 (±100 G)
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual power supply: ±7 VDC
Single-end power supply: 14 VDC
Recommended Excitation Dual power supply: ±2.5 to ±6 VDC
Single-end power supply: 5 to 12 VDC
Current Consumption 20 mA or less (5 VDC)
Cable Sensor to relay
7-conductor (0.04 mm2) vinyl shielded cable, 2.4 mm diameter by 5 m long
Relay to connector
7-conductor (0.04 mm2) vinyl shielded cable, 2.4 mm diameter by 2 m long, terminated with a connector plug (PRC03-12A10-7M)
(*Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads ±39228 m/s2(±4000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 2k Hz (Sensitivity deviation: ±10%)
Weight 9 g (Excluding cable)
Dimensions 15 W × 6.3 H × 11 D mm (Excluding cable)

Dimensions

AMAS-A

AMAS-A-200
±200 G

AMAS-A-200

Specifications

Performance
Rated Capacity ±1961 m/s2 (±200 G)
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±1%/ºC
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual power supply: ±7 VDC
Single-end power supply: 14 VDC
Recommended Excitation Dual power supply: ±2.5 to ±6 VDC
Single-end power supply: 5 to 12 VDC
Current Consumption 20 mA or less (5 VDC)
Cable Sensor to relay
7-conductor (0.04 mm2) vinyl shielded cable, 2.4 mm diameter by 5 m long
Relay to connector
7-conductor (0.04 mm2) vinyl shielded cable, 2.4 mm diameter by 2 m long, terminated with a connector plug (PRC03-12A10-7M)
(*Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads ±39228 m/s2(±4000 G)
Transverse Sensitivity 4% RO or less
Frequency Response DC to 2k Hz (Sensitivity deviation: ±10%)
Weight 9 g (Excluding cable)
Dimensions 15 W × 6.3 H × 11 D mm (Excluding cable)

Dimensions

AMAS-A

Page Top

Remarks

* When using the Conditioner Cards for EDX Series CVM-41A and AD-40AS, an external power supply unit is not required.

eBook

Download

Recommended products for combination