AS-GA
Small-sized Small-capacity Acceleration Transducer

Summary
The AS-GA is an oil damping type small-sized acceleration transducer for measuring small acceleration. Its cable can be removed easily.
Rated Capacity: ±9.807 to ±196.1 m/s2
Dimensions: 14 x 18 x 14 mm
Rated Output: 0.5 mV/V or more
Frequency Response: DC to (40 to 250) Hz
Features
• Compact & lightweight and easy to use
• Suitable for scale models and human engineering.
• TEDS-installed versions can be manufactured.
Products table
All display
AS-1GA
Hermetic Terminal Type ±1 G

Specifications
Performance
Rated Capacity | ±9.807 m/s2(±1 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -15 to 65ºC |
---|
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 3 V AC or DC |
Input Resistance | 121 Ω ±1.7% |
Output Resistance | 121 Ω ±1.7% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long Dedicated cable CB-AS-GA Sensor side: Dedicated connector (removable) Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Frequency Response | DC to 40 Hz at 23ºC (Sensitivity deviation ±5%) |
Transverse Sensitivity | 4% RO or less |
Weight | Approx. 15 g (Excluding cable) |
Dimensions

AS-2GA
Hermetic Terminal Type ±2 G

Specifications
Performance
Rated Capacity | ±19.61 m/s2(±2 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -15 to 65ºC |
---|
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 3 V AC or DC |
Input Resistance | 121 Ω ±1.7% |
Output Resistance | 121 Ω ±1.7% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long Dedicated cable CB-AS-GA Sensor side: Dedicated connector (removable) Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Frequency Response | DC to 60 Hz at 23ºC (Sensitivity deviation ±5%) |
Transverse Sensitivity | 4% RO or less |
Weight | Approx. 15 g (Excluding cable) |
Dimensions

AS-5GA
Hermetic Terminal Type ±5 G

Specifications
Performance
Rated Capacity | ±49.03 m/s2(±5 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -15 to 65ºC |
---|
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 3 V AC or DC |
Input Resistance | 121 Ω ±1.7% |
Output Resistance | 121 Ω ±1.7% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long Dedicated cable CB-AS-GA Sensor side: Dedicated connector (removable) Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Frequency Response | DC to 100 Hz at 23ºC (Sensitivity deviation ±5%) |
Transverse Sensitivity | 4% RO or less |
Weight | Approx. 15 g (Excluding cable) |
Dimensions

AS-10GA
Hermetic Terminal Type ±10 G

Specifications
Performance
Rated Capacity | ±98.07 m/s2(±10 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -15 to 65ºC |
---|
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 3 V AC or DC |
Input Resistance | 121 Ω ±1.7% |
Output Resistance | 121 Ω ±1.7% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long Dedicated cable CB-AS-GA Sensor side: Dedicated connector (removable) Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Frequency Response | DC to 150 Hz at 23ºC (Sensitivity deviation ±5%) |
Transverse Sensitivity | 4% RO or less |
Weight | Approx. 15 g (Excluding cable) |
Dimensions

AS-20GA
Hermetic Terminal Type ±20 G

Specifications
Performance
Rated Capacity | ±196.1 m/s2(±20 G) |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -15 to 65ºC |
---|
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 3 V AC or DC |
Input Resistance | 121 Ω ±1.7% |
Output Resistance | 121 Ω ±1.7% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long Dedicated cable CB-AS-GA Sensor side: Dedicated connector (removable) Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Frequency Response | DC to 250 Hz at 23ºC (Sensitivity deviation ±5%) |
Transverse Sensitivity | 4% RO or less |
Weight | Approx. 15 g (Excluding cable) |
Dimensions

Remarks
The acceleration transducer is subject to a constant acceleration in the direction of gravity, therefore measurement is restricted, taking into account this vertical movement (9.807 m/s2).
For the AS-1GA, AS-1GB, if sensitivity is set in line with the direction of gravity, then the rated capacity will be exceeded.
As long as the safe overload rating is not exceeded, there will be no damage, but characteristics will be outside the guaranteed range.
*CE compliant models are available. Inquiries are welcome.