The AS-GB is an oil damping type small-sized acceleration transducer for measuring small acceleration. Its cable fixed to the sensor that cannot be removed.
Rated Capacity: ±9.807 to ±196.1 m/s2 Dimensions: 14 x 20 x 14 mm Rated Output: 0.5 mV/V or more Frequency Response: DC to (40 to 250) Hz
Features
• Compact & lightweight and easy to use • Suitable for scale models and human engineering. • TEDS-installed versions can be manufactured.
Products table
All display
AS-1GB Cable Integrated Type ±1 G
Specifications
Performance
Rated Capacity
±9.807 m/s2(±1 G)
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.5 mV/V or more
Environmental Characteristics
Safe Temperature
-15 to 65ºC
Electrical Characteristics
Safe Excitation
6 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
121 Ω ±1.7%
Output Resistance
121 Ω ±1.7%
Cable
4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
300%
Frequency Response
DC to 40 Hz at 23ºC (Sensitivity deviation ±5%)
Transverse Sensitivity
4% RO or less
Weight
Approx. 25 g (Excluding cable)
Dimensions
AS-2GB Cable Integrated Type ±2 G
Specifications
Performance
Rated Capacity
±19.61 m/s2(±2 G)
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.5 mV/V or more
Environmental Characteristics
Safe Temperature
-15 to 65ºC
Electrical Characteristics
Safe Excitation
6 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
121 Ω ±1.7%
Output Resistance
121 Ω ±1.7%
Cable
4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
300%
Frequency Response
DC to 60 Hz at 23ºC (Sensitivity deviation ±5%)
Transverse Sensitivity
4% RO or less
Weight
Approx. 25 g (Excluding cable)
Dimensions
AS-5GB Cable Integrated Type ±5 G
Specifications
Performance
Rated Capacity
±49.03 m/s2(±5 G)
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.5 mV/V or more
Environmental Characteristics
Safe Temperature
-15 to 65ºC
Electrical Characteristics
Safe Excitation
6 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
121 Ω ±1.7%
Output Resistance
121 Ω ±1.7%
Cable
4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
300%
Frequency Response
DC to 100 Hz at 23ºC (Sensitivity deviation ±5%)
Transverse Sensitivity
4% RO or less
Weight
Approx. 25 g (Excluding cable)
Dimensions
AS-10GB Cable Integrated Type ±10 G
Specifications
Performance
Rated Capacity
±98.07 m/s2(±10 G)
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.5 mV/V or more
Environmental Characteristics
Safe Temperature
-15 to 65ºC
Electrical Characteristics
Safe Excitation
6 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
121 Ω ±1.7%
Output Resistance
121 Ω ±1.7%
Cable
4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
300%
Frequency Response
DC to 150 Hz at 23ºC (Sensitivity deviation ±5%)
Transverse Sensitivity
4% RO or less
Weight
Approx. 25 g (Excluding cable)
Dimensions
AS-20GB Cable Integrated Type ±20 G
Specifications
Performance
Rated Capacity
±196.1 m/s2(±20 G)
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.5 mV/V or more
Environmental Characteristics
Safe Temperature
-15 to 65ºC
Electrical Characteristics
Safe Excitation
6 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
121 Ω ±1.7%
Output Resistance
121 Ω ±1.7%
Cable
4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
To install AS-GB, use CC-33A adhesive or optional mount base.
The acceleration transducer is subject to a constant acceleration in the direction of gravity, therefore measurement is restricted, taking into account this vertical movement (9.807 m/s2). For the AS-1GA, AS-1GB, if sensitivity is set in line with the direction of gravity, then the rated capacity will be exceeded. As long as the safe overload rating is not exceeded, there will be no damage, but characteristics will be outside the guaranteed range.
*CE compliant models are available. Inquiries are welcome.