High immunity against external force (interference) High safe vertical force, and hard to break down These transducers are designed to measure skin friction resistance force between a sinking caisson and the ground. They can suitably be used to control settlement and posture of the caisson.
Features
●Model providing a desired skin friction force can be manufactured. ●For measurement under the same conditions as around the installation site, the BEH-C-S series is designed for concrete shells and the BEH-D-S series, for steel shells. ●Receive no adverse effect from water pressure changing while they are sinking.
Products table
All display
BEH-D-200KPS Steel shells, 200 kPa
Specifications
Performance
Purpose
Steel case
Rated Capacity
200 kPa
Nonlinearity
Within ±1%RO
Hysteresis
Within ±1%RO
Rated Output
Approx. 1.5 mV/V
Environmental Characteristics
Safe Temperature
-20 to 65ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.1%RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
Approx. 350 Ω
Output Resistance
Approx. 350 Ω
Cable
4-conductor (0.5 mm2 ) chloroprene shielded cable, 10 mm diameter by 2 m long, bared at the tip (Shield is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Allowable Vertical Force
20 kN
Frictional Load
20 kN
Withstand Water Pressure
500 kPa
Degree of Protection
IP68 (500 kPa), (IEC 60529)
Dimensions
BEH-D-300KPS Steel shells, 300 kPa
Specifications
Performance
Purpose
Steel case
Rated Capacity
300 kPa
Nonlinearity
Within ±1%RO
Hysteresis
Within ±1%RO
Rated Output
Approx. 1.5 mV/V
Environmental Characteristics
Safe Temperature
-20 to 65ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.1%RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
Approx. 350 Ω
Output Resistance
Approx. 350 Ω
Cable
4-conductor (0.5 mm2 ) chloroprene shielded cable, 10 mm diameter by 2 m long, bared at the tip (Shield is not connected to the case.)