BER-A-110S
Wall-surface Soil Pressure Transducer

Summary

Stainless steel models can be manufactured for wave pressure measurement.
The BER-A-110S soil pressure transducers come with the cable attached in parallel to the pressure-sensing surface

Features

●Wear of the pressure sensing surface does not affect output or initial values.
●Load cell-based design is less affected by bending effects.
●Usable for pressure measurement of coal or grain in a silo
●For pressure measurement of pulverulent bodies of approximately 15 mm in diameter

Products table

All display

BER-A-100KP110S
100 kPa

Specifications

Performance
Rated Capacity 100 kPa
Calculated Loads 709 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Presure-sensing Surface Approx. φ95 mm
Materials Pressure sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa
Degree of Protection IP68 (IEC 60529) , (600 kPa)
Weight Approx. 2.2 kg

Dimensions

BER-A-110S

BER-A-200KP110S
200 kPa

Specifications

Performance
Rated Capacity 200 kPa
Calculated Loads 1.4 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Presure-sensing Surface Approx. φ95 mm
Materials Pressure sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa
Degree of Protection IP68 (600 kPa), (IEC 60529)
Weight Approx. 2.2 kg

Dimensions

BER-A-110S

BER-A-500KP110S
500 kPa

Specifications

Performance
Rated Capacity 500 kPa
Calculated Loads 3.5 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Presure-sensing Surface Approx. φ95 mm
Materials Pressure sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa
Degree of Protection IP68 (600 kPa), (IEC 60529)
Weight Approx. 2.2 kg

Dimensions

BER-A-110S

BER-A-1MP110S
1 MPa

Specifications

Performance
Rated Capacity 1 MPa
Calculated Loads 7.1 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Presure-sensing Surface Approx. φ95 mm
Materials Pressure sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa
Degree of Protection IP68 (600 kPa), (IEC 60529)
Weight Approx. 2.2 kg

Dimensions

BER-A-110S

BER-A-2MP110S
2 MPa

Specifications

Performance
Rated Capacity 2 MPa
Calculated Loads 14.2 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Presure-sensing Surface Approx. φ95 mm
Materials Pressure sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa
Degree of Protection IP68 (600 kPa), (IEC 60529)
Weight Approx. 2.2 kg

Dimensions

BER-A-110S

Page Top

To Ensure Safe Usage

Do not apply a load more than the rated capacity (pressure, load) to the applied pressure surface. (See table below)