BER-A-110S Wall-surface Soil Pressure Transducer
Summary
Stainless steel models can be manufactured for wave pressure measurement. The BER-A-110S soil pressure transducers come with the cable attached in parallel to the pressure-sensing surface
Features
●Wear of the pressure sensing surface does not affect output or initial values. ●Load cell-based design is less affected by bending effects. ●Usable for pressure measurement of coal or grain in a silo ●For pressure measurement of pulverulent bodies of approximately 15 mm in diameter
BER-A-100KP110S 100 kPa
Specifications
Performance
Rated Capacity
100 kPa
Calculated Loads
709 N
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
1 to 5 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.5 mm2 ) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Presure-sensing Surface
Approx. φ95 mm
Materials
Pressure sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet)
600 kPa
Degree of Protection
IP68 (IEC 60529) , (600 kPa)
Weight
Approx. 2.2 kg
BER-A-200KP110S 200 kPa
Specifications
Performance
Rated Capacity
200 kPa
Calculated Loads
1.4 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
1 to 5 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.5 mm2 ) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Presure-sensing Surface
Approx. φ95 mm
Materials
Pressure sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet)
600 kPa
Degree of Protection
IP68 (600 kPa), (IEC 60529)
Weight
Approx. 2.2 kg
BER-A-500KP110S 500 kPa
Specifications
Performance
Rated Capacity
500 kPa
Calculated Loads
3.5 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
1 to 5 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.5 mm2 ) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Presure-sensing Surface
Approx. φ95 mm
Materials
Pressure sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet)
600 kPa
Degree of Protection
IP68 (600 kPa), (IEC 60529)
Weight
Approx. 2.2 kg
BER-A-1MP110S 1 MPa
Specifications
Performance
Rated Capacity
1 MPa
Calculated Loads
7.1 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
1 to 5 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.5 mm2 ) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Presure-sensing Surface
Approx. φ95 mm
Materials
Pressure sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet)
600 kPa
Degree of Protection
IP68 (600 kPa), (IEC 60529)
Weight
Approx. 2.2 kg
BER-A-2MP110S 2 MPa
Specifications
Performance
Rated Capacity
2 MPa
Calculated Loads
14.2 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
1 to 5 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.5 mm2 ) chloroprene cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
120%
Presure-sensing Surface
Approx. φ95 mm
Materials
Pressure sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet)
600 kPa
Degree of Protection
IP68 (600 kPa), (IEC 60529)
Weight
Approx. 2.2 kg
Page Top
To Ensure Safe Usage
Do not apply a load more than the rated capacity (pressure, load) to the applied pressure surface. (See table below)