BER-A-58S
Wall-surface Soil Pressure Transducer

Summary

Suitable for the chamber soil pressure of a shield machine, or backfill pressure measurement.
BER-A-12S/58S is an soil pressure transducers of the load cell type designed not to be subject to the influence of a structure bending.These are suitable for surface-of-a-wall soil pressure measurement.ince the 2-model (12, 58) preparations of these are made, they can choose the model united in the installation direction.

Features

●Wear of the pressure sensing surface does not affect output or initial values. 
●Load cell-based design is less affected by bending effects.
●This is for granular material pressure measurement whose particle diameter is about φ10.

Products table

All display

BER-A-500KP58S
500 kPa

Specifications

Performance
Rated Capacity 500 kPa
Calculated Loads 2.1 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 3.1 kg
Presure-sensing Surface Approx. φ73
Materials Pressure sensing surface: Stainless steel
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa

Dimensions

BER-A-58S

BER-A-1MP58S
1 MPa

Specifications

Performance
Rated Capacity 1 MPa
Calculated Loads 4.2 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 3.1 kg
Presure-sensing Surface Approx. φ73
Materials Pressure sensing surface: Stainless steel
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa

Dimensions

BER-A-58S

BER-A-2MP58S
2 MPa

Specifications

Performance
Rated Capacity 2 MPa
Calculated Loads 8.4 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 5 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 3.1 kg
Presure-sensing Surface Approx. φ73
Materials Pressure sensing surface: Stainless steel
Flange and cable outlet: ZnC-plated MF
Water Resistance (Cable outlet) 600 kPa

Dimensions

BER-A-58S

Page Top

To Ensure Safe Usage