BER-S-12SA3
Wall-surface Soil Pressure Transducer

BER-S-12SA2

Summary

With a stopper
Safe overloads: 1000%

Features

●High overload protection (Safe overloads up to 1000%)
●Excellent characteristics against eccentric load (Little change in sensitivity and others)

Products table

All display

BER-S-500KP12SA3Z30
500 kPa

BER-S-12SA2

Specifications

Performance
Rated Capacity 500 kPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 1.0 mV/V
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure)
Safe overload of pore pressure (including gas) is 3 MPa.
Only when soil pressure is applied to the pressure receiving surface equally.
Exterior Pressure-sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Pressure Resistance (Cable outlet) 600 kPa
Weight 3.1 kg (Excluding cable)

Dimensions

BER-S-500KP12SA3Z30

BER-S-1MP12SA3Z30
1 MPa

BER-S-12SA2

Specifications

Performance
Rated Capacity 1 MPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 1.0 mV/V
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure)
Safe overload of pore pressure (including gas) is 3 MPa.
Only when soil pressure is applied to the pressure receiving surface equally.
Exterior Pressure-sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Pressure Resistance (Cable outlet) 600 kPa
Weight 4.4 kg (Excluding cable)

Dimensions

BER-S-1MP12SA3Z30

BER-S-2MP12SA3Z30
2 MPa

BER-S-12SA2

Specifications

Performance
Rated Capacity 2 MPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 1.0 mV/V
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure)
Safe overload of pore pressure (including gas) is 3 MPa.
Only when soil pressure is applied to the pressure receiving surface equally.
Exterior Pressure-sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Pressure Resistance (Cable outlet) 600 kPa
Weight 4.4 kg (Excluding cable)

Dimensions

BER-S-2MP12SA3Z30

BER-S-3MP12SA3Z30
3 MPa

BER-S-12SA2

Specifications

Performance
Rated Capacity 3 MPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 1.0 mV/V
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure)
Safe overload of pore pressure (including gas) is 3 MPa.
Only when soil pressure is applied to the pressure receiving surface equally.
Exterior Pressure-sensing surface: Stainless steel metallic finish
Flange and cable outlet: ZnC-plated MF
Water Pressure Resistance (Cable outlet) 600 kPa
Weight 4.4 kg (Excluding cable)

Dimensions

BER-S-3MP12SA3Z30

Page Top

Remarks