BER-S-12SA3
Wall-surface Soil Pressure Transducer

Summary
With a stopper
Safe overloads: 1000%
Features
●High overload protection (Safe overloads up to 1000%)
●Excellent characteristics against eccentric load (Little change in sensitivity and others)
Products table
All display
BER-S-500KP12SA3Z30
500 kPa

Specifications
Performance
Rated Capacity | 500 kPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | Approx. 1.0 mV/V |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | 0 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure) Safe overload of pore pressure (including gas) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Pressure-sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | 3.1 kg (Excluding cable) |
Dimensions

BER-S-1MP12SA3Z30
1 MPa

Specifications
Performance
Rated Capacity | 1 MPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | Approx. 1.0 mV/V |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | 0 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure) Safe overload of pore pressure (including gas) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Pressure-sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | 4.4 kg (Excluding cable) |
Dimensions

BER-S-2MP12SA3Z30
2 MPa

Specifications
Performance
Rated Capacity | 2 MPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | Approx. 1.0 mV/V |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | 0 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure) Safe overload of pore pressure (including gas) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Pressure-sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | 4.4 kg (Excluding cable) |
Dimensions

BER-S-3MP12SA3Z30
3 MPa

Specifications
Performance
Rated Capacity | 3 MPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | Approx. 1.0 mV/V |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | 0 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Powdered pressure + Pore pressure) Safe overload of pore pressure (including gas) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Pressure-sensing surface: Stainless steel metallic finish Flange and cable outlet: ZnC-plated MF |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | 4.4 kg (Excluding cable) |
Dimensions

Remarks
*For pressure measurement of pulverulent bodies within φ10 mm (Powdered & pore pressure)