BER-S-35SA1
Wall-surface Soil Pressure Transducer

Summary
With a stopper
Safe overloads: 1000%
Features
●Outstanding 1000% overload
●Regular capacity models are available
Products table
All display
BER-S-500KP35SA1
500 kPa

Specifications
Performance
Rated Capacity | 500 kPa |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±2% RO |
Rated Output | Approx. 1.5 mV/V |
Environmental Characteristics
Safe Temperature | -30 to 80ºC |
---|---|
Compensated Temperature | 0 to 70ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Effective stress + Pore water pressure) Safe overload of pore water pressure (including gas pressure) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Stainless steel metallic finish |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | Approx. 400 g (Excluding cable) |
Dimensions

BER-S-1MP35SA1
1 MPa

Specifications
Performance
Rated Capacity | 1 MPa |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±2% RO |
Rated Output | Approx. 1.5 mV/V |
Environmental Characteristics
Safe Temperature | -30 to 80ºC |
---|---|
Compensated Temperature | 0 to 70ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Effective stress + Pore water pressure) Safe overload of pore water pressure (including gas pressure) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Stainless steel metallic finish |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | Approx. 400 g (Excluding cable) |
Dimensions

BER-S-2MP35SA1
2 MPa

Specifications
Performance
Rated Capacity | 2 MPa |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±2% RO |
Rated Output | Approx. 1.5 mV/V |
Environmental Characteristics
Safe Temperature | -30 to 80ºC |
---|---|
Compensated Temperature | 0 to 70ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Effective stress + Pore water pressure) Safe overload of pore water pressure (including gas pressure) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Stainless steel metallic finish |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | Approx. 400 g (Excluding cable) |
Dimensions

BER-S-3MP35SA1
3 MPa

Specifications
Performance
Rated Capacity | 3 MPa |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±2% RO |
Rated Output | Approx. 1.5 mV/V |
Environmental Characteristics
Safe Temperature | -30 to 80ºC |
---|---|
Compensated Temperature | 0 to 70ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 12 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 10 mm diameter by 30 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 1000% soil pressure (Soil pressure = Effective stress + Pore water pressure) Safe overload of pore water pressure (including gas pressure) is 3 MPa. Only when soil pressure is applied to the pressure receiving surface equally. |
---|---|
Exterior | Stainless steel metallic finish |
Water Pressure Resistance (Cable outlet) | 600 kPa |
Weight | Approx. 400 g (Excluding cable) |
Dimensions

Remarks
*For pressure measurement of pulverulent bodies φ3 mm or less (Powdered & pore pressure)