BFD-A-TS
Reinforcing-bar Stress Transducer

BFD-A-TS

Summary

For stress measurement of reinforcing bar
The BFD-A-TS series transducers are designed for stress measurement of reinforcing bars whose nominal diameters are larger than those measured by the BF-CT series. The BFD-A-TS series is used by welding both ends to a reinforcing bar in the field. Select the model suitable for the diameter of the reinforcing bar. Each model provides a temperature measuring function to enable simultaneous measurement of stress and temperature.

Features

●For long-term stable measurement, the transducer proper features a special structure with inert gas filled in.
●The self-temperature-compensated strain gage used for the transducer enables measurement of temperature stress of the reinforcing bar.

Products table

All display

BFD-A-35TS
Nominal Diameter (Deformed Bar): D35

BFD-A-TS

Specifications

Performance
Stress Measurement
Rated Capacity 300 MPa (1 MPa = 1 N/mm2)
(Please contact sales staff about rated capacity for 350 to 400 MPa.)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1.85 mV/V or more
Temperature Measurement
Rated Capacity -30 to 70ºC
Measurement Error ±0.5ºC (-30 to 70ºC)
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Input Resistance 350 Ω ±2% at 0ºC
Output Resistance 450 Ω ±2% at 0ºC
Cable 4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads 110%
Nominal Diameter (Deformed Bar) D35
Materials Metallic finish
Other
Applicable Reinforcing Bar SD345 (Formerly, SD35)

Dimensions

BFD-A-TS

BFD-A-38TS
Nominal Diameter (Deformed Bar): D38

BFD-A-TS

Specifications

Performance
Stress Measurement
Rated Capacity 300 MPa (1 MPa = 1 N/mm2)
(Please contact sales staff about rated capacity for 350 to 400 MPa.)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1.85 mV/V or more
Temperature Measurement
Rated Capacity -30 to 70ºC
Measurement Error ±0.5ºC (-30 to 70ºC)
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Input Resistance 350 Ω ±2% at 0ºC
Output Resistance 450 Ω ±2% at 0ºC
Cable 4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads 110%
Nominal Diameter (Deformed Bar) D38
Materials Metallic finish
Other
Applicable Reinforcing Bar SD345 (Formerly, SD35)

Dimensions

BFD-A-TS

BFD-A-41TS
Nominal Diameter (Deformed Bar): D41

BFD-A-TS

Specifications

Performance
Stress Measurement
Rated Capacity 300 MPa (1 MPa = 1 N/mm2)
(Please contact sales staff about rated capacity for 350 to 400 MPa.)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1.85 mV/V or more
Temperature Measurement
Rated Capacity -30 to 70ºC
Measurement Error ±0.5ºC (-30 to 70ºC)
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Input Resistance 350 Ω ±2% at 0ºC
Output Resistance 450 Ω ±2% at 0ºC
Cable 4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads 110%
Nominal Diameter (Deformed Bar) D41
Materials Metallic finish
Other
Applicable Reinforcing Bar SD345 (Formerly, SD35)

Dimensions

BFD-A-TS

BFD-A-51TS
Nominal Diameter (Deformed Bar): D51

BFD-A-TS

Specifications

Performance
Stress Measurement
Rated Capacity 300 MPa (1 MPa = 1 N/mm2)
(Please contact sales staff about rated capacity for 350 to 400 MPa.)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1.85 mV/V or more
Temperature Measurement
Rated Capacity -30 to 70ºC
Measurement Error ±0.5ºC (-30 to 70ºC)
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Input Resistance 350 Ω ±2% at 0ºC
Output Resistance 450 Ω ±2% at 0ºC
Cable 4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads 110%
Nominal Diameter (Deformed Bar) D51
Materials Metallic finish
Other
Applicable Reinforcing Bar SD345 (Formerly, SD35)
Reinforcing-Bar Please provide reinforcing-bar for BFD-A-51TS to Kyowa.2 pieces x 335 mm long
Calibration The BFD-A-51TS is calibrated by applying to a single sensing section, compressive load (approx. 600 kN) equivalent to the rated capacity of 300 MPa and compressive load (approx. 670 kN) equivalent to the safe overload rating.

Dimensions

BFD-A-TS