The BJ-AT is a joint transducer suitable for checking an opening of concrete blocks at the joint. Rated Capacity: 5 to 50 mm (Displacement), -30 to 70ºC (Temperature) Nonlinearity: Within ±1.5% RO Rated Output: 1 mV/V or more
Features
• Suitable for checking an opening of concrete blocks at the joint or cracks initiated mainly by temperature change • Also as an ordinary displacement transducer • For embedment in concrete, the dedicated receptacle CJS-1C is embedded in advance in a preceding block and the joint transducer is in stalled to the next block.
Products table
All display
BJ-5AT 5 mm
Specifications
Performance
Displacement Measurement
Rated Capacity
5 mm
Nonlinearity
Within ±1.5% RO
Hysteresis
Within ±1.5% RO
Rated Output
1 mV/V or more, tension: + output
Temperature Measurement
Rated Capacity
-30 to 70ºC
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% at 0ºC
Output Resistance
450 Ω ±0.8% at 0ºC
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
120%
Weight
Approx. 790 g (Excluding cable)
Dimensions
BJ-10AT 10 mm
Specifications
Performance
Displacement Measurement
Rated Capacity
10 mm
Nonlinearity
Within ±1.5% RO
Hysteresis
Within ±1.5% RO
Rated Output
1 mV/V or more, tension: + output
Temperature Measurement
Rated Capacity
-30 to 70ºC
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% at 0ºC
Output Resistance
450 Ω ±0.8% at 0ºC
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
120%
Weight
Approx. 790 g (Excluding cable)
Dimensions
BJ-20AT 20 mm
Specifications
Performance
Displacement Measurement
Rated Capacity
20 mm
Nonlinearity
Within ±1.5% RO
Hysteresis
Within ±1.5% RO
Rated Output
1 mV/V or more, tension: + output
Temperature Measurement
Rated Capacity
-30 to 70ºC
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% at 0ºC
Output Resistance
450 Ω ±0.8% at 0ºC
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
120%
Weight
Approx. 790 g (Excluding cable)
Dimensions
BJ-50AT 50 mm
Specifications
Performance
Displacement Measurement
Rated Capacity
50 mm
Nonlinearity
Within ±1.5% RO
Hysteresis
Within ±1.5% RO
Rated Output
1 mV/V or more, tension: + output
Temperature Measurement
Rated Capacity
-30 to 70ºC
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% at 0ºC
Output Resistance
450 Ω ±0.8% at 0ºC
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip