BK-G
Insertion Type Inclination Transducer

Summary
Inclination angles detected enable measurement of lateral displacement of the ground or earth retaining wall.
BK-G series inclination transducers are designed for insertion in aluminum guide pipe embedded beforehand, in the ground or the structure, detect successive inclination angles and measure lateral displacement.
The transducer is essential for checking landslide or earth retaining wall, and often used for measuring lateral displacement of the ground or earth retaining wall. 3 m cable to connect the cord reel and measurement devices is also included.
Features
●Highly reliable performance backed by durable structure ensure safe use in civil engineering fields.
●Cable and reel are standard accessories, the cable enables measurement up to 50m deep.
Products table
All display
BK-5G
Inclination Measurement, ±5º

Specifications
Performance
Rated Capacity | ±5º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 2.182 mV/V ±0.5% (Minus rated capacity to plus rated capacity) |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | -20 to 50ºC |
Temperature Effect on Zero | Within ±0.03% RO/ºC |
Temperature Effect on Output | Within ±0.03%/ºC |
Electrical Characteristics
Input Resistance | 500 to 660 Ω |
---|---|
Output Resistance | 343 to 357 Ω |
Cable | ① 4-conductor (0.5 mm2) polyurethane cable incorporating piano wire, 9 mm diameter by 60 m long (10 m of a reserve portion is included.) The mark is put on the cable every 50 cm for the depth check. ② 4-conductor (0.3 mm2) chloroprene shielded cable, 7.8 mm diameter by 3 m long Code reel side: Terminated with a waterproof connector plug 1108-12A10-7M Measuring instrument side: Terminated with a connector plug PRC03-12A10-7M |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | Approx. 3.2 kg (Excluding cable) |
Optional Accessories | Aluminum guide pipe B-30 (3 m) Aluminum guide pipe socket B-35 (30 cm) |
---|
Dimensions

BK-10G
Inclination Measurement, ±10º

Specifications
Performance
Rated Capacity | ±10º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 2.182 mV/V ±0.5% (Minus rated capacity to plus rated capacity) |
Environmental Characteristics
Safe Temperature | -20 to 60ºC |
---|---|
Compensated Temperature | -20 to 50ºC |
Temperature Effect on Zero | Within ±0.03% RO/ºC |
Temperature Effect on Output | Within ±0.03%/ºC |
Electrical Characteristics
Input Resistance | 500 to 660 Ω |
---|---|
Output Resistance | 343 to 357 Ω |
Cable | ① 4-conductor (0.5 mm2) polyurethane cable incorporating piano wire, 9 mm diameter by 60 m long (10 m of a reserve portion is included.) The mark is put on the cable every 50 cm for the depth check. ② 4-conductor (0.3 mm2) chloroprene shielded cable, 7.8 mm diameter by 3 m long Code reel side: Terminated with a waterproof connector plug 1108-12A10-7M Measuring instrument side: Terminated with a connector plug PRC03-12A10-7M |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | Approx. 3.2 kg (Excluding cable) |
Optional Accessories | Aluminum guide pipe B-30 (3 m) Aluminum guide pipe socket B-35 (30 cm) |
---|
Dimensions

Remarks
*60 m or longer cables can be manufactured.