BK-G
Insertion Type Inclination Transducer

Summary

Inclination angles detected enable measurement of lateral displacement of the ground or earth retaining wall.
BK-G series inclination transducers are designed for insertion in aluminum guide pipe embedded beforehand, in the ground or the structure, detect successive inclination angles and measure lateral displacement.
The transducer is essential for checking landslide or earth retaining wall, and often used for measuring lateral displacement of the ground or earth retaining wall. 3 m cable to connect the cord reel and measurement devices is also included.

Features

●Highly reliable performance backed by durable structure ensure safe use in civil engineering fields.
●Cable and reel are standard accessories, the cable enables measurement up to 50m deep.

Products table

All display

BK-5G
Inclination Measurement, ±5º

Specifications

Performance
Rated Capacity ±5º
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 2.182 mV/V ±0.5%
(Minus rated capacity to plus rated capacity)
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature -20 to 50ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.03%/ºC
Electrical Characteristics
Input Resistance 500 to 660 Ω
Output Resistance 343 to 357 Ω
Cable ① 4-conductor (0.5 mm2) polyurethane cable incorporating piano wire,
9 mm diameter by 60 m long (10 m of a reserve portion is included.)
  The mark is put on the cable every 50 cm for the depth check.

② 4-conductor (0.3 mm2) chloroprene shielded cable, 7.8 mm diameter by 3 m long
Code reel side: Terminated with a waterproof connector plug
1108-12A10-7M
Measuring instrument side: Terminated with a connector plug
PRC03-12A10-7M
Mechanical Properties
Safe Overloads 120%
Weight Approx. 3.2 kg (Excluding cable)
Optional Accessories Aluminum guide pipe B-30 (3 m)
Aluminum guide pipe socket B-35 (30 cm)

Dimensions

BK-G

BK-10G
Inclination Measurement, ±10º

Specifications

Performance
Rated Capacity ±10º
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 2.182 mV/V ±0.5%
(Minus rated capacity to plus rated capacity)
Environmental Characteristics
Safe Temperature -20 to 60ºC
Compensated Temperature -20 to 50ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.03%/ºC
Electrical Characteristics
Input Resistance 500 to 660 Ω
Output Resistance 343 to 357 Ω
Cable ① 4-conductor (0.5 mm2) polyurethane cable incorporating piano wire,
9 mm diameter by 60 m long (10 m of a reserve portion is included.)
  The mark is put on the cable every 50 cm for the depth check.

② 4-conductor (0.3 mm2) chloroprene shielded cable, 7.8 mm diameter by 3 m long
Code reel side: Terminated with a waterproof connector plug
1108-12A10-7M
Measuring instrument side: Terminated with a connector plug
PRC03-12A10-7M
Mechanical Properties
Safe Overloads 120%
Weight Approx. 3.2 kg (Excluding cable)
Optional Accessories Aluminum guide pipe B-30 (3 m)
Aluminum guide pipe socket B-35 (30 cm)

Dimensions

BK-G

Page Top

Remarks

*60 m or longer cables can be manufactured.