BKK-A
Surface-mounting Type Inclination Transducer

Summary
These transducers provide not only resolution twice as high as conventional systems but also outstandingly improved temperature characteristics and long-term stability.
The BKK-A series inclination transducers on surface of structure. available in two types, uniaxial and biaxial, are designed to measure minute inclination quantities. They are suitably used in combination with a structural settlement transducer for measurement of the disturbance resulting from nearby engineering works as well as for measurement of landslide-initiated inclination of the ground surface.
These transducers provide not only resolution twice as high as conventional systems but also outstandingly improved temperature characteristics (temperature effect on zero balance ±0.36 seconds/°C with ±1° rated capacity) and long-term stability (±0.5% RO). Furthermore, a stopper for detector protection is provided to ensure high handling efficiency in a total working flow from transportation to installation and measurement. Also, their structure, with highly viscous damping oil filled in, improves vibration resistance.
Features
●External stopper provided
●Improved vibration resistance
●Biaxial type available (BKK-A-D)
Products table
All display
BKK-A-1
1 direction, ±1º

Specifications
Performance
Rated Capacity | ±1º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 2 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.02%/ºC |
Long-term Stability | Within ±0.5% RO (For 6 months) This value is based on actual measurement and stated with dispersion taken into consideration. Stability slowly changes during a few months after installation, and then tends to become constant. |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±1% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Measuring Direction | Uniaxial |
---|---|
Safe Overloads | 120% |
Material | Chromate-plated |
Degree of Protection | IP56 (IEC 60529) |
Weight | Approx.6.0 kg |
Standard Accessories | Stopper fixing wing nut |
---|---|
Optional Accessories | ●Wall-mounting Fixtures Designed to mount BKK-A transducers onto a wall surface; chromate-plated. BD-11A (For mounting 1 unit) BD-12A (For mounting 2 units) ●Horizontal Surface-mounting Fixtures Designed to mount BKK-A transducers onto a horizontal surface; chromate-plated. BD-31A (For mounting 1 unit) BD-32A (For mounting 2 units) ●Wall Protection Covers Designed to protect BKK-A transducers against external mechanical force; metal covers painted in grey. BD-21A (For BD-11A) BD-22A (For BD-12A) BD-41A (For BD-31A) BD-42A (For BD-32A) |
Dimensions

BKK-A-1-D
2 directions, ±1º

Specifications
Performance
Rated Capacity | ±1º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 2 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.02%/ºC |
Long-term Stability | Within ±0.5% RO (For 6 months) This value is based on actual measurement and stated with dispersion taken into consideration. Stability slowly changes during a few months after installation, and then tends to become constant. |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±1% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long, bared at the tip (2 cables for biaxial models) (Shield wire is not connected to the case.) |
Mechanical Properties
Measuring Direction | Biaxial |
---|---|
Safe Overloads | 120% |
Interference | Within ±1% RO |
Material | Chromate-plated |
Degree of Protection | IP56 (IEC 60529) |
Weight | Approx.6.8 kg |
Standard Accessories | Stopper fixing wing nut |
---|---|
Optional Accessories | ●Wall-mounting Fixtures Designed to mount BKK-A transducers onto a wall surface; chromate-plated. BD-11A (For mounting 1 unit) BD-12A (For mounting 2 units) ●Horizontal Surface-mounting Fixtures Designed to mount BKK-A transducers onto a horizontal surface; chromate-plated. BD-31A (For mounting 1 unit) BD-32A (For mounting 2 units) ●Wall Protection Covers Designed to protect BKK-A transducers against external mechanical force; metal covers painted in grey. BD-21A (For BD-11A) BD-22A (For BD-12A) BD-41A (For BD-31A) BD-42A (For BD-32A) |
Dimensions

BKK-A-2
1 direction, ±2º

Specifications
Performance
Rated Capacity | ±2º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 3 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.02%/ºC |
Long-term Stability | Within ±0.5% RO (For 6 months) This value is based on actual measurement and stated with dispersion taken into consideration. Stability slowly changes during a few months after installation, and then tends to become constant. |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±1% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Measuring Direction | Uniaxial |
---|---|
Safe Overloads | 120% |
Material | Chromate-plated |
Degree of Protection | IP56 (IEC 60529) |
Weight | Approx.5.5 kg |
Standard Accessories | Stopper fixing wing nut |
---|---|
Optional Accessories | ●Wall-mounting Fixtures Designed to mount BKK-A transducers onto a wall surface; chromate-plated. BD-11A (For mounting 1 unit) BD-12A (For mounting 2 units) ●Horizontal Surface-mounting Fixtures Designed to mount BKK-A transducers onto a horizontal surface; chromate-plated. BD-31A (For mounting 1 unit) BD-32A (For mounting 2 units) ●Wall Protection Covers Designed to protect BKK-A transducers against external mechanical force; metal covers painted in grey. BD-21A (For BD-11A) BD-22A (For BD-12A) BD-41A (For BD-31A) BD-42A (For BD-32A) |
Dimensions

BKK-A-2-D
2 directions, ±2º

Specifications
Performance
Rated Capacity | ±2º |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.5% RO |
Rated Output | 3 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.02%/ºC |
Long-term Stability | Within ±0.5% RO (For 6 months) This value is based on actual measurement and stated with dispersion taken into consideration. Stability slowly changes during a few months after installation, and then tends to become constant. |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±1% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long, bared at the tip (2 cables for biaxial models) (Shield wire is not connected to the case.) |
Mechanical Properties
Measuring Direction | Biaxial |
---|---|
Safe Overloads | 120% |
Interference | Within ±1% RO |
Material | Chromate-plated |
Degree of Protection | IP56 (IEC 60529) |
Weight | Approx.6.3 kg |
Standard Accessories | Stopper fixing wing nut |
---|---|
Optional Accessories | ●Wall-mounting Fixtures Designed to mount BKK-A transducers onto a wall surface; chromate-plated. BD-11A (For mounting 1 unit) BD-12A (For mounting 2 units) ●Horizontal Surface-mounting Fixtures Designed to mount BKK-A transducers onto a horizontal surface; chromate-plated. BD-31A (For mounting 1 unit) BD-32A (For mounting 2 units) ●Wall Protection Covers Designed to protect BKK-A transducers against external mechanical force; metal covers painted in grey. BD-21A (For BD-11A) BD-22A (For BD-12A) BD-41A (For BD-31A) BD-42A (For BD-32A) |
Dimensions