BL-B
Hollowed Load Cell

Summary
The BL-B series is a hollowed load cell. It is developed to accurately measure the loads applied to earth anchors, PC anchors and the supports of tunnel arches.
Rated Capacity: 5 kN to 500 kN
Diameter: 98 mm (5 kN to 50 kN), 129 mm (100 kN), 90 mm (200 kN), 115 mm (500 kN)
Nonlinearity: Within ±1% RO (5 kN to 100 kN), within ±2% RO (200 kN), within ±0.6% RO (500 kN)
Features
• Most suitable for field measurement
• Water-proof structure
• High accuracy model
Products table
All display
BL-500KB
5 kN

Specifications
Performance
Rated Capacity | 5 kN |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 3 kg |
Hollow Diameters | 26 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-1TB
10 kN

Specifications
Performance
Rated Capacity | 10 kN |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 3 kg |
Hollow Diameters | 26 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-2TB
20 kN

Specifications
Performance
Rated Capacity | 20 kN |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 3 kg |
Hollow Diameters | 26 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-5TB
50 kN

Specifications
Performance
Rated Capacity | 50 kN |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 3 kg |
Hollow Diameters | 26 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-10TB
100 kN

Specifications
Performance
Rated Capacity | 100 kN |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 7.5 kg |
Hollow Diameters | 26 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. * A round saddle is also available for option. |
---|
Dimensions

BL-20TB
200 kN

Specifications
Performance
Rated Capacity | 200 kN |
---|---|
Nonlinearity | Within ±2% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 1.6 kg |
Hollow Diameters | 43 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-50TB
500 kN

Specifications
Performance
Rated Capacity | 500 kN |
---|---|
Nonlinearity | Within ±0.6% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | 3.3 kg |
Hollow Diameters | 80 |
---|
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions