BL-E
Hollowed Load Cell

Summary

The BL-E is a hollowed load cell for measuring large loads applied to earth anchors, PC anchors and supports of tunnel arches.
Rated Capacity: 1 MN, 2 MN
Diameter: 140 mm (1 MN), 210 mm (2 MN)
Nonlinearity: Within ±0.5% RO (1 MN), within ±1.5% RO (2 MN)

Features

• Most suitable for field measurement
• Water-proof structure
• High accuracy

Products table

All display

BL-100TE
1 MN

Specifications

Performance
Rated Capacity 1 MN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 6.6 kg
Optional Accessories Saddle for BL-type Load Cells
Dimensions (D) and (t) are available in
the following range depending on rated capacity.
D = 100 x 100 mm to 400 x 400 mm
t = 20 to 50 mm
●Inform us the dimensions of the part of equipment which contacts with the saddle.
 *A round saddle is also available for option.

Dimensions

BL-100TE

BL-200TE
2 MN

Specifications

Performance
Rated Capacity 2 MN
Nonlinearity Within ±1.5% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx.14.1 kg
Optional Accessories Saddle for BL-type Load Cells
Dimensions (D) and (t) are available in the following range depending on rated capacity.
D = 100 x 100 mm to 400 x 400 mm
t = 20 to 50 mm
Inform us the dimensions of the part of equipment which contacts with the saddle.
 *A round saddle is also available for option.

Dimensions

BL-200TE

Page Top

Download