BL-E
Hollowed Load Cell

Summary
The BL-E is a hollowed load cell for measuring large loads applied to earth anchors, PC anchors and supports of tunnel arches.
Rated Capacity: 1 MN, 2 MN
Diameter: 140 mm (1 MN), 210 mm (2 MN)
Nonlinearity: Within ±0.5% RO (1 MN), within ±1.5% RO (2 MN)
Features
• Most suitable for field measurement
• Water-proof structure
• High accuracy
Products table
All display
BL-100TE
1 MN

Specifications
Performance
Rated Capacity | 1 MN |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | Approx. 6.6 kg |
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm ●Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions

BL-200TE
2 MN

Specifications
Performance
Rated Capacity | 2 MN |
---|---|
Nonlinearity | Within ±1.5% RO |
Hysteresis | Within ±1% RO |
Rated Output | 1 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±2% |
Output Resistance | 350 Ω ±2% |
Cable | 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | Approx.14.1 kg |
Optional Accessories | Saddle for BL-type Load Cells Dimensions (D) and (t) are available in the following range depending on rated capacity. D = 100 x 100 mm to 400 x 400 mm t = 20 to 50 mm Inform us the dimensions of the part of equipment which contacts with the saddle. *A round saddle is also available for option. |
---|
Dimensions