BLW-A
Hollowed Load Cell

BLW-A

Summary

The BLW-A is a hollowed load cell for measuring loads of VSL anchors, etc.
Rated Capacity: 500 kN to 2 MN
Diameter: 188 mm (500 kN), 223.5 mm (1 MN), 263.5 mm (1500 kN, 2 MN)
Nonlinearity: Within ±0.8% RO

Features

• Eccentric loads, inner or outer loads causes less sensitivity deviation
• Thin & lightweight
• Water-proof structure (IP68 (IEC 60529) (Water pressure 0.5 MPa for 24 hours at 23ºC±15ºC))

Products table

All display

BLW-A-500KN
500 kN

blw-a-500kn_pict_01.png

Specifications

Performance
Rated Capacity 500 kN
Nonlinearity Within ±0.8% RO
Hysteresis Within ±0.5% RO
Rated Output 1.25 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.3%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Degree of Protection IP68 (IEC 60529)(Under 0.5 MPa water pressure, for 24 h at 23°C ±15°C)
Weight Approx.4 kg

Dimensions

BLW-A

BLW-A-1MN
1 MN

BLW-A

Specifications

Performance
Rated Capacity 1 MN
Nonlinearity Within ±0.8% RO
Hysteresis Within ±0.5% RO
Rated Output 1.25 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.3%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Degree of Protection IP68 (IEC 60529)(Under 0.5 MPa water pressure, for 24 h at 23°C ±15°C)
Weight Approx.8 kg

Dimensions

BLW-A

BLW-A-1500KN
1500 kN

BLW-A

Specifications

Performance
Rated Capacity 1500 kN
Nonlinearity Within ±0.8% RO
Hysteresis Within ±0.5% RO
Rated Output 1.25 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.3%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Degree of Protection IP68(IEC 60529) (Under 0.5 MPa water pressure, for 24 h at 23ºC ±15ºC)
Weight Approx.14 kg

Dimensions

BLW-A

BLW-A-2MN
2 MN

BLW-A

Specifications

Performance
Rated Capacity 2 MN
Nonlinearity Within ±0.8% RO
Hysteresis Within ±0.5% RO
Rated Output 1.25 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.3%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 1 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Degree of Protection IP68 (IEC 60529)(Under 0.5 MPa water pressure, for 24 h at 23°C ±15°C)
Weight Approx.14.5 kg

Dimensions

BLW-A

Page Top

Download