BLWL-B
Hollowed Load Cell

BLWL-B

Summary

It can be used to measure loads of ground anchors, PC anchors, tunnel timbering, etc. either existed or new one.

Rated Capacity: 500 kN, 1 MN
Diameter: 158 mm (500 kN), 193 mm (1 MN)
Nonlinearity: Within ±1% RO

Features

• Being waterproof ensures field usage IP67 (IEC 60529)
• Lower price than the conventional models

Products table

All display

BLWL-B-500KNSA3
500 kN

BLWL-B

Specifications

Performance
Rated Capacity 500 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 1 mV/V
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Degree of Protection IP67 (IEC 60529)
Weight Approx. 4.4 kg

Dimensions

BLWL-B

BLWL-B-1MNSA3
1 MN

BLWL-B

Specifications

Performance
Rated Capacity 1 MN
Nonlinearity Within ±1% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 1 mV/V
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Degree of Protection IP67 (IEC 60529)
Weight Approx. 6.2 kg

Dimensions

BLW-B

Page Top

Remarks

1) Both nonlinearity and hysteresis are the calibrated values.
 Depends on the load surface and the load direction, they may exceed the spec. value.
2) When installing, never apply eccentricity load on it.
3) The specifications are the values under uniform load on the load surface.

As for 1.5 MN and others, please contact us.

As for existed anchors, the collaborative items Tensile Jigs and Jacks are required.