For underground pore pressure measurement Embedded in soil, BPC-A transducers measure underground pore pressures. A double-cased structure lets them perform without receiving any adverse effect from lateral pressures and makes them suitable for measurement where underground soil pressures change significantly. The cable length may be as desired.
Features
Double-cased structure ensures measurement without receiving any effect of lateral pressure. Flat filter (10μm mesh standard) is provided to prevent the sensing part from clogging. Stainless steel case (including flat filter FB-10SUS)
Products table
All display
BPC-A-200KP 200 kPa
Specifications
Performance
Rated Capacity
200 kPa
Nonlinearity
Within ±2% RO
Hysteresis
Within ±1% RO
Rated Output
0.75 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC (Non-freezing)
Compensated Temperature
0 to 60ºC (Non-freezing)
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1%
Output Resistance
350 Ω ±1%
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
150%
Weight
Approx. 550 g (Excluding cable)
Dimensions
BPC-A-500KP 500 kPa
Specifications
Performance
Rated Capacity
500 kPa
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC (Non-freezing)
Compensated Temperature
0 to 60ºC (Non-freezing)
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1%
Output Resistance
350 Ω ±1%
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
150%
Weight
Approx. 550 g (Excluding cable)
Dimensions
BPC-A-1MP 1 MPa
Specifications
Performance
Rated Capacity
1 MPa
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC (Non-freezing)
Compensated Temperature
0 to 60ºC (Non-freezing)
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1%
Output Resistance
350 Ω ±1%
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
150%
Weight
Approx. 550 g (Excluding cable)
Dimensions
BPC-A-2MP 2 MPa
Specifications
Performance
Rated Capacity
2 MPa
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
1 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC (Non-freezing)
Compensated Temperature
0 to 60ºC (Non-freezing)
Temperature Effect on Zero
Within ±0.1% RO/ºC
Temperature Effect on Output
Within ±0.1%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1%
Output Resistance
350 Ω ±1%
Cable
4-conductor (0.5 mm2) chloroprene cable, 11.5 mm diameter by 1 m long, bared at the tip