Enables measure concrete stress directly as stress and not via strain A temperature measuring function enable them to measure stress and temperature simultaneously.
Features
●Theoretically backed performance of direct concrete stress measurement with no conversion from a detected strain quantity. ●Receive minimal effects of creep and changing elastic modulus of concrete. and there by ensure accurate stress measurement. ●Also usable for stress measurement of the natural ground by installing at the rear of a tunnel lining.
Products table
All display
BR-20KBT 2 MPa
Specifications
Performance
Stress Measurement
Rated Capacity
2 MPa
Temperature Measurement
Rated Capacity
-30 to 70ºC
Stress Measurement
Nonlinearity
Within ±1% RO
Hysteresis
Within ±0.5% RO
Rated Output
1 mV/V or more
Temperature Measurement
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% (At 0ºC)
Output Resistance
450 Ω ±0.8% (At 0ºC)
Cable
4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
150%
Weight
Approx. 2.9 kg (Excluding cable)
Dimensions
BR-50KBT 5 MPa
Specifications
Performance
Stress Measurement
Rated Capacity
5 MPa
Temperature Measurement
Rated Capacity
-30 to 70ºC
Stress Measurement
Nonlinearity
Within ±1% RO
Hysteresis
Within ±0.5% RO
Rated Output
1 mV/V or more
Temperature Measurement
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% (At 0ºC)
Output Resistance
450 Ω ±0.8% (At 0ºC)
Cable
4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip
Mechanical Properties
Safe Overloads
150%
Weight
Approx. 2.9 kg (Excluding cable)
Dimensions
BR-100KBT 10 MPa
Specifications
Performance
Stress Measurement
Rated Capacity
10 MPa
Temperature Measurement
Rated Capacity
-30 to 70ºC
Stress Measurement
Nonlinearity
Within ±1% RO
Hysteresis
Within ±0.5% RO
Rated Output
1 mV/V or more
Temperature Measurement
Measurement Error
±0.5ºC (-30 to 70ºC) (When measuring temperatures by using Kyowa's civil engineering transducers with a thermal sensor.)
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
10 V AC or DC
Recommended Excitation
2 to 10 V AC or DC
Input Resistance
350 Ω ±1% (At 0ºC)
Output Resistance
450 Ω ±0.8% (At 0ºC)
Cable
4-conductor (0.5 mm2) chloroprene cable, 8 mm diameter by 1 m long, bared at the tip