DLT-BS
Inductance-type Displacement Transducer

Summary

The DLT-BS is a water-proof displacement transducer.
Rated Capacity: ±5 to ±500 mm
Nonlinearity: Within ±0.5%RO
Rated Output: Approx. 2 mV/V

Features

• Complete shielding against magnetism makes the transducers hard to receive external electric effects.
• Stable against temperature changes
• Non-contact design between the core and mainframe ensures durability.
• A carrier-type dynamic strain amplifier in DPM series should be used for combination.

Products table

All display

DLT-5BS
±5 mm

Specifications

Performance
Rated Capacity ±5 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 200 Hz
Weight Approx. 700 g

Dimensions

DLT-BS

DLT-10BS
±10 mm

Specifications

Performance
Rated Capacity ±10 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 100 Hz
Weight Approx. 700 g

Dimensions

DLT-BS

DLT-20BS
±20 mm

Specifications

Performance
Rated Capacity ±20 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 50 Hz
Weight Approx. 800 g

Dimensions

DLT-BS

DLT-30BS
±30 mm

Specifications

Performance
Rated Capacity ±30 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 30 Hz
Weight Approx. 800 g

Dimensions

DLT-BS

DLT-50BS
±50 mm

Specifications

Performance
Rated Capacity ±50 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 20 Hz
Weight Approx. 900 g

Dimensions

DLT-BS

DLT-100BS
±100 mm

Specifications

Performance
Rated Capacity ±100 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 15 Hz
Weight Approx. 1.2 kg

Dimensions

DLT-AS

DLT-150BS
±150 mm

Specifications

Performance
Rated Capacity ±150 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 10 Hz
Weight Approx. 2.3 kg

Dimensions

DLT-BS

DLT-200BS
±200 mm

Specifications

Performance
Rated Capacity ±200 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 9Hz
Weight Approx. 2.6 kg

Dimensions

DLT-BS

DLT-300BS
±300 mm

Specifications

Performance
Rated Capacity ±300 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 7Hz
Weight Approx. 3.3 kg

Dimensions

DLT-AS

DLT-500BS
±500 mm

Specifications

Performance
Rated Capacity ±500 mm (Watertight model conforming to IEC 60529)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2 mV/V
Environmental Characteristics
Safe Temperature -15 to 75ºC (Non-condensing)
Compensated Temperature -10 to 60ºC (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Detection Method Inductance
Safe Excitation 5 VAC (Carrier frequency 5 kHz)
Recommended Excitation 2 VAC (Carrier frequency 5 kHz)
Input Resistance 120 Ω ±1%
Output Resistance 120 Ω ±1%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
Mechanical Properties
Frequency Response DC to 5 Hz
Weight Approx. 5 kg

Dimensions

DLT-BS

Page Top

To Ensure Safe Usage

To Ensure Safe Usage
• The transducer may be mounted with an accessory mounting fixture or with the mounting screws on the top of case.
• The carrier frequency affects the output voltage and characteristics of transducers. Thus, any dynamic strain amplifier with bridge excitation at other than 5 kHz mustn't be used.
(Also, any amplifier with DC bridge excitation mustn't be used.)

Download

Recommended products for combination