The DT-A is a displacement transducer for both tension and compression measurement. It has a dial for reading measured displacement directly. Rated Capacity: 50, 100 mm Nonlinearity: Within ±0.5% RO Measuring Force: Approx. 4.4 N Rated Output: 1.5 mV/V ±20%
Features
• Easy installation, handling & maintenance • Connectable to strain amplifier for measurement • TEDS-installed versions can be manufactured.
Products table
All display
DT-50A 50 mm
Specifications
Performance
Rated Capacity
50 mm
Nonlinearity
Within ±0.5% RO
Hysteresis
Within ±0.5% RO
Repeatability
0.3% RO or less
Rated Output
1.5 mV/V ±20%
Environmental Characteristics
Safe Temperature
0 to 60ºC (Non-condensing)
Compensated Temperature
0 to 50ºC (Non-condensing)
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
5 V AC or DC
Recommended Excitation
1 to 4 V AC or DC
Input Resistance
120 Ω ±3%
Output Resistance
120 Ω ±3%
Cable
4-conductor (0.08 mm2) chloroprene shielded cable, 4 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
Mechanical Properties
Frequency Response
DC to approx. 1.5 Hz
Measuring Force
Approx. 4.4 N
Weight
Approx. 380 g (Excluding cable)
Optional Accessories
Magnet base MB-B
Dimensions
DT-100A 100 mm
Specifications
Performance
Rated Capacity
100 mm
Nonlinearity
Within ±0.5% RO
Hysteresis
Within ±0.5% RO
Repeatability
0.3% RO or less
Rated Output
1.5 mV/V ±20%
Environmental Characteristics
Safe Temperature
0 to 60ºC (Non-condensing)
Compensated Temperature
0 to 50ºC (Non-condensing)
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
5 V AC or DC
Recommended Excitation
1 to 4 V AC or DC
Input Resistance
120 Ω ±3%
Output Resistance
120 Ω ±3%
Cable
4-conductor (0.08 mm2) chloroprene shielded cable, 4 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.)
(Note 1) Replacement probe X, XS, SH, or X does not apply. (Note 2) Extension rods do not apply. (Note 3) Avoid usage in vibration. (Note 4) If large displacement is applied momentarily, it takes some time that output is settled. (Note 5) Do not apply any displacement in other than expansion/contraction direction of the rod.
Remarks
To Ensure Safe Usage • Fix the transducer to a steady point by the M6 bolt. • DT-A series transducers are designed to provide the smallest possible measuring force. Thus, the rod may not move with the displacement when the transducer is mounted upward. In such a case, detach the probe and fix the rod to the steady point using a nut.