DTK-A
Displacement Transducer

Summary
The DTK-A is a small-sized displacement transducer for both tension and compression measurement.
A measuring scale provided.
Rated Capacity: 30, 50 mm
Nonlinearity: Within ±0.3% RO
Measuring Force: Approx. 2 N
Rated Output: 2.5 mV/V or more
Features
• Small and angular
• Easy installation
• TEDS-installed models are available.
Products table
All display
DTK-A-30
30 mm

Specifications
Performance
Rated Capacity | 30 mm |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.3% RO |
Repeatability | 0.3% RO or less |
Rated Output | 2.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -10 to 70ºC (Non-condensing) |
---|---|
Compensated Temperature | 0 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.05% RO/ºC |
Temperature Effect on Output | Within ±0.05% /ºC |
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 5 V AC or DC |
Input Resistance | 350 Ω ±3% |
Output Resistance | 350 Ω ±3% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Frequency Response | DC to approx. 10 Hz |
---|---|
Measuring Force | Approx. 2 N |
Weight | Approx. 25 g (Excluding cable) |
Standard Accessories | Mounting plate: 1 Hexagon socket head bolt (M3×6): 2 Pin (φ2×20): 1 |
---|---|
Optional Accessories | Extension rod EB-50, EB-100 Mounting band FXB-30B Replacement probes X, XS, SH, H Magnet base MB-B |
Dimensions

DTK-A-50
50 mm

Specifications
Performance
Rated Capacity | 50 mm |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.3% RO |
Repeatability | 0.3% RO or less |
Rated Output | 2.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -10 to 70ºC (Non-condensing) |
---|---|
Compensated Temperature | 0 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.05% RO/ºC |
Temperature Effect on Output | Within ±0.05% /ºC |
Electrical Characteristics
Safe Excitation | 6 V AC or DC |
---|---|
Recommended Excitation | 1 to 5 V AC or DC |
Input Resistance | 350 Ω ±3% |
Output Resistance | 350 Ω ±3% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Frequency Response | DC to approx. 6 Hz |
---|---|
Measuring Force | Approx. 2 N |
Weight | Approx. 34 g (Excluding cable) |
Standard Accessories | Mounting plate: 1 Hexagon socket head bolt (M3×6): 2 Pin (φ2×20): 1 |
---|---|
Optional Accessories | Extension rod EB-50, EB-100 Mounting band FXB-30B Replacement probes X, XS, SH, H Magnet base MB-B |
Dimensions

To Ensure Safe Usage
Fix the transducer by using the provided mounting plate and a M6 bolt.
Remarks
(Note 1) Avoid usage in vibration.
(Note 2) If large displacement is applied momentarily, it takes some time that output is settled.
(Note 3) Do not apply any displacement in other than expansion/contraction direction of the rod.
*CE compliant models are available. Inquiries are welcome.