DTP-E-S
Drip Proof Large-capacity Displacement Transducer

Summary

The DTP-E-S is a potentiometer type displacement transducer with drip proof for measuring displacement by extending or contracting wire.
Rated Capacity: 500, 1000, 2000 mm
Nonlinearity: Within ±1% RO
Measuring Force: Approx. 9.8 N (500 mm), approx. 4.9 N (1000, 2000 mm)
Rated Output: Approx. 5 mV/V

Features

• Connectable to strain amplifier for measurement
• Degrees of protection: IP67 (IEC 60529)

Products table

All display

DTP-E-500S
500mm

Specifications

Performance
Rated Capacity 500 mm
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 5 mV/V
Environmental Characteristics
Compensated Temperature -10 to 60ºC
Electrical Characteristics
Detection Method Potentiometer
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Measuring Force Approx. 9.8 N
Cycling Life 104 times
Degree of Protection IP67 (IEC 60529)
Frame Stainless

Dimensions

DTP-E-S

DTP-E-1KS
1000mm

Specifications

Performance
Rated Capacity 1000 mm
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 5 mV/V
Environmental Characteristics
Compensated Temperature -10 to 60ºC
Electrical Characteristics
Detection Method Potentiometer
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Measuring Force Approx. 4.9 N
Cycling Life 104 times
Degree of Protection IP67 (IEC 60529)
Frame Stainless

DTP-E-2KS
2000mm

Specifications

Performance
Rated Capacity 2000 mm
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output Approx. 5 mV/V
Environmental Characteristics
Compensated Temperature -10 to 60ºC
Electrical Characteristics
Detection Method Potentiometer
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 9.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Measuring Force Approx. 4.9 N
Cycling Life 104 times
Degree of Protection IP67 (IEC 60529)
Frame Stainless

Page Top

To Ensure Safe Usage

This Transducer cannot be used for a dynamic measurement,a measurement object with rapid movement and a micr o vibration.