DTS-A
Displacement Transducer

Summary
The DTS-A is a displacement transducer for both tension and compression measurement.
Rated Capacity: 100 mm
Nonlinearity: Within ±0.3% RO
Measuring Force: Approx. 5 N
Rated Output: 2.5 mV/V ±10%
Features
• Reduce creep
• Both tension and compression
• High frequency response (DC to 50 Hz when the tip is fixed)
• Strain-gage type
Products table
All display
DTS-A-100
100 mm

Specifications
Performance
Rated Capacity | 100 mm |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.3% RO |
Repeatability | 0.1% RO or less |
Rated Output | 2.5 mV/V ±10% |
Environmental Characteristics
Safe Temperature | -10 to 70ºC (Non-condensing) |
---|---|
Compensated Temperature | 0 to 60ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.05% RO/ºC |
Temperature Effect on Output | Within ±0.05% /ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 5 V AC or DC |
I/O Resistance | In: 350 Ω ±3% Out: 255 Ω ±10% |
Cable | 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by 1 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Frequency Response | DC to approx. 6 Hz (When the tip is touching to the testing machine, displacement: 100 mm) (Reference: DC to approx. 50 Hz, when the tip is fixed, displacement: 30 mm) |
---|---|
Measuring Force | Approx. 5 N |
Weight | Approx. 110 g (Excluding cable) |
Degree of Protection | IP40 (IEC 60529) |
Standard Accessories | Mounting band FXBP-100A: 2 Adapter: 1 |
---|---|
Optional Accessories | Extension rods: EB-50, EB-100, EB-200, EB-300 Mounting band FXBP-100A Replacement probes: X, XS, SH |
Dimensions

Remarks
(Note 1) Do not apply any displacement in other than expansion/contraction direction of the rod.
*CE compliant models are available. Inquiries are welcome.