GTI-E210-S
Pad-type Soil Pressure Transducers

Summary

The surface of transducer-installed segment is smooth and does not disturb soil pressure distribution.
Soil pressure transducers in GTI-E210-S series provide a pressure-sensing pad for installation along the curvature of a segment in shield driving applications. Thus, these transducers can accurately measure average soil pressure applied to a wide area of a segment or back-filling.

Features

● Large-sized pressure-sensing surface enables detection of average soil pressure.
● Sensor can be installed without any loss of the segment section due to blocking.
● Smooth segment surface after installation does not affect soil pressure distribution.
● Can be installed independent of the type of segment or engineering process.
● Can be installed even to a surface having a curvature. (For the limit of the curvature, contact a KYOWA representative.)

Products table

All display

GTI-E210-500KPS
500 kPa

Specifications

Performance
Rated Capacity 500 kPa
Nonlinearity Within ±1%RO
Hysteresis Within ±1%RO
Rated Output Approx. 1 mV/V or more
Environmental Characteristics
Safe Temperature 0 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1%RO/ºC (*)
Temperature Effect on Output Within ±0.1%/ºC (*)
Electrical Characteristics
Recommended Excitation 2 to 10 VAC or DC
Input Resistance 350 Ω±1%
Output Resistance 350 Ω±1%
Cable 4-conductor ( 0.5 mm2 ) chloroprene cable, 11.5 mm diameter by 5 m long, bared at the tip
Mechanical Properties
Safe Overloads 120%
Wrapping corrosion-proof painting,Steel metallic finish
Degree of Protection IP68 (Safe overload), (IEC 60529)

Dimensions

GTI-E210-1MPS
1 MPa

Specifications

Performance
Rated Capacity 1 MPa
Nonlinearity Within ±1%RO
Hysteresis Within ±1%RO
Rated Output Approx. 1 mV/V or more
Environmental Characteristics
Safe Temperature 0 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1%RO/ºC (*)
Temperature Effect on Output Within ±0.1%/ºC (*)
Electrical Characteristics
Recommended Excitation 2 to 10 VAC or DC
Input Resistance 350 Ω±1%
Output Resistance 350 Ω±1%
Cable 4-conductor ( 0.5 mm2 ) chloroprene cable, 11.5 mm diameter by 5 m long, bared at the tip
Mechanical Properties
Safe Overloads 120%
Wrapping corrosion-proof painting,Steel metallic finish
Degree of Protection IP68 (Safe overload), (IEC 60529)

Dimensions

Page Top

To Ensure Safe Usage

●The pad is made of a thin metal sheet. Do not strike it against any sharp or angular matters.
●Mounting fixture is required for installation.

Remarks

Transducers in this series were developed jointly with the Regional Ground and Environment Research Center.