LC-V
Small-sized Compression Load Cell

  • CE

Summary

The LC-V is a compact & lightweight load cell for measuring compressive loads. It is easy installation into existing facilities. The Steady Brace ensures to cancel transverse loads resulted from horizontal displacement.
Rated Capacity: 50 kN to 200 kN
Diameter: 68 mm (50 kN), 78 mm (100 kN), 98 mm (200 kN)
Nonlinearity: Within ±0.05% RO

Features

• Hermetically-sealed structure with inert gas filled in
• Long cycle life: 10 million cycles or more
• BISELCOM® gages are used
* BISELCOM gages are self-temperature-compensation strain gages with the sensitivity-temperature-compensation function added.

Products table

All display

LC-5TV
50 kN

  • CE

Specifications

Performance
Rated Capacity 50 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.03% RO or less
Rated Output 2.5 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm)
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 17 kHz
Weight Approx. 1 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Compliance Directive 2011/65/EU (RoHS)
Optional Accessories Saddle CA-B
Mount Base CF
Steady brace CR

Dimensions

LC-TV

LC-10TV
100 kN

  • CE

Specifications

Performance
Rated Capacity 100 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.03% RO or less
Rated Output 2.5 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm)
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 16 kHz
Weight Approx. 1.3 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Compliance Directive 2011/65/EU (RoHS)
Optional Accessories Saddle CA-B
Mount Base CF
Steady brace CR

Dimensions

LC-TV

LC-20TV
200 kN

  • CE

Specifications

Performance
Rated Capacity 200 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.03% RO or less
Rated Output 2.5 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm)
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 15 kHz
Weight Approx. 3.1 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Compliance Directive 2011/65/EU (RoHS)
Optional Accessories Saddle CA-B
Mount Base CF
Steady brace CR