LCF-2TA
Femur Load Cell

Summary
For Femur of a Crash Dummy
Mounted to the femur of a crash dummy such as Hybrid III, the LCF-2TA detects impact-initiated load to the femur.
Features
●Conforms to Federal Motor Vehicle Safety Standard 208 as a sensor to obtain injury rating
Products table
All display
LCF-2TA
20 kN

Specifications
Performance
Rated Capacity | 20 kN |
---|---|
Nonlinearity | Within ±0.4% RO |
Hysteresis | Within ±0.4% RO |
Repeatability | 0.2% RO or less |
Rated Output | 1 to 1.5 mV/V (2000 to 3000 ×10-6 strain) |
Environmental Characteristics
Safe Temperature | -10 to 70ºC |
---|---|
Compensated Temperature | 0 to 60ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Electrical Characteristics
Safe Excitation | 10 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±3% |
Output Resistance | 350 Ω ±3% |
Cable | 4-conductor (0.065 mm2) vinyl shielded cable, 4 mm diameter by 5 m long, bared at the tip (Shield wire is connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Weight | Approx. 700 g |
Dimensions