The LCH-F is a high accuracy load cell. It is the highest measuring accuracy in high humidity place. Rated Capacity: 100 kN, 200 kN Diameter: 156 mm (100 kN), 176 mm (200 kN) Nonlinearity: Within ±0.02% RO
Features
• Remote sensing* * To use the remote sensing function, use the remote-sensing compatible products. • Degrees of protection: IP67 (IEC 60529)
Products table
All display
LCH-10TF 100 kN
Specifications
Performance
Rated Capacity
100 kN
Nonlinearity
Within ±0.02% RO
Hysteresis
Within ±0.02% RO
Repeatability
0.02% RO or less
Rated Output
2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature
-35 to 80ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.0015% RO/ºC
Temperature Effect on Output
Within ±0.001%/ºC
Electrical Characteristics
Safe Excitation
20 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±0.5%
Output Resistance
350 Ω ±0.5%
Cable
6-conductor (0.5 mm2) chloroprene shielded cable,9.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Natural Frequencies
Approx. 7.5 kHz
Weight
Approx. 12 kg (Excluding cable)
Degree of Protection
IP64 (IEC 60529)
Optional Accessories
Saddle CA-50B
Dimensions
LCH-20TF 200 kN
Specifications
Performance
Rated Capacity
200 kN
Nonlinearity
Within ±0.02% RO
Hysteresis
Within ±0.02% RO
Repeatability
0.02% RO or less
Rated Output
2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature
-35 to 80ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.0015% RO/ºC
Temperature Effect on Output
Within ±0.001%/ºC
Electrical Characteristics
Safe Excitation
20 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±0.5%
Output Resistance
350 Ω ±0.5%
Cable
6-conductor (0.5 mm2) chloroprene shielded cable,9.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)