LCR-G-SA2
Small-sized Large-capacity Compression Load Cell

Summary

The LCR-G-SA2 is a compact & lightweight load cell for measuring compressive loads.
Rated Capacity: 10 to 50 kN
Diameter: 20 mm (10 to 30 kN), 25 mm (50 kN)
Nonlinearity: Within ±1% RO
Others: Since the cable comes from the bottom, the load cells can be inserted into cylindrical objects for measurement.

Features

• For cylinders
• Diameter: φ11 to 16.5 mm
• Metallic finish

Products table

All display

LCR-G-10KNSA2
10 kN

Specifications

Performance
Rated Capacity 10 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -10 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 100 g (Excluding cable)
Materials Metallic finish

Dimensions

LCR-G-SA2

LCR-G-20KNSA2
20 kN

Specifications

Performance
Rated Capacity 20 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -10 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 100 g (Excluding cable)
Materials Metallic finish

Dimensions

LCR-G-SA2

LCR-G-30KNSA2
30 kN

Specifications

Performance
Rated Capacity 30 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -10 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 100 g (Excluding cable)
Materials Metallic finish

Dimensions

LCR-G-SA2

LCR-G-50KNSA2
50 kN

Specifications

Performance
Rated Capacity 50 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1 mV/V or more
Environmental Characteristics
Safe Temperature -10 to 70ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 120%
Weight Approx. 130 g (Excluding cable)
Materials Metallic finish

Dimensions

LCR-G-SA2

Page Top

Download

Catalogs

Recommended products for combination