LCS-D
Explosion-proof Construction Compression Load Cell

Summary

The LCS-D is a load cell for measuring compressive loads. It can be used under environment to be subjected to explosion. For details, please contact us.

Features

* For details, please contact us.

Products table

All display

LCS-500KD
5 kN

Specifications

Performance
Rated Capacity 5 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Repeatability 0.2% RO or less
Rated Output 2 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -15 to 75ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.007% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Explosion-proof Environmental Conditions Ambient Temperature: -10 to 40ºC
Relative Humidity: 45 to 85%
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 120%
Natural Frequencies Approx. 4 kHz
Weight Approx. 4.5 kg
Optional Accessories Saddle CA-B
Mount Base CF
Movable saddle ER-B

Dimensions

LCS-D

LCS-1TD
10 kN

Specifications

Performance
Rated Capacity 10 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Repeatability 0.2% RO or less
Rated Output 2 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -15 to 75ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.007% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Explosion-proof Environmental Conditions Ambient Temperature: -10 to 40ºC
Relative Humidity: 45 to 85%
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 120%
Natural Frequencies Approx. 5.3 kHz
Weight Approx. 4.5 kg
Optional Accessories Saddle CA-B
Mount Base CF
Movable saddle ER-B

Dimensions

LCS-D

LCS-2TD
20 kN

Specifications

Performance
Rated Capacity 20 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Repeatability 0.2% RO or less
Rated Output 2 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -15 to 75ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.007% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Explosion-proof Environmental Conditions Ambient Temperature: -10 to 40ºC
Relative Humidity: 45 to 85%
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 120%
Natural Frequencies Approx. 6.2 kHz
Weight Approx. 4.5 kg
Optional Accessories Saddle CA-B
Mount Base CF
Movable saddle ER-B

Dimensions

LCS-D

LCS-5TD
50 kN

Specifications

Performance
Rated Capacity 50 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Repeatability 0.2% RO or less
Rated Output 2 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -15 to 75ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.007% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Explosion-proof Environmental Conditions Ambient Temperature: -10 to 40ºC
Relative Humidity: 45 to 85%
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 120%
Natural Frequencies Approx. 6 kHz
Weight Approx. 4.5 kg
Optional Accessories Saddle CA-B
Mount Base CF
Movable saddle ER-B

Dimensions

LCS-D

Page Top

Download

Catalogs