LCTS-B
Stainless Steel Load Cell

Summary

The LCTS-B is a stainless-steel load cell for measuring compressive loads of hoppers and weighing tanks. The built-in steady brace mechanism makes LCTS-B suitable for weighing stirring tanks or tank feet.
Rated Capacity: 5 kN to 100 kN
Diameter: 175 mm (5 kN to 30 kN), 200 mm (50 kN, 100 kN)
Nonlinearity: Within ±0.05% RO

Features

• Easily install on hopper's brackets and tank's legs
• Hermetically-sealed structure (IP67 (IEC 60529))
• TEDS-installed versions can be manufactured.

Products table

All display

LCTS-B-5KN
5 kN

Specifications

Performance
Rated Capacity 5 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 10 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 5 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

LCTS-B-10KN
10 kN

Specifications

Performance
Rated Capacity 10 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 10 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 5 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

LCTS-B-20KN
20 kN

Specifications

Performance
Rated Capacity 20 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 10 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 5 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

LCTS-B-30KN
30 kN

Specifications

Performance
Rated Capacity 30 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 10 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 6 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

LCTS-B-50KN
50 kN

Specifications

Performance
Rated Capacity 50 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long , bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 30 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 11 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

LCTS-B-100KN
100 kN

Specifications

Performance
Rated Capacity 100 kN
Nonlinearity Within ±0.05% RO
Hysteresis Within ±0.05% RO
Repeatability 0.02% RO or less
Rated Output 2 mV/V ±0.1%
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature -10 to 60ºC
Temperature Effect on Zero Within ±0.003% RO/ºC
Temperature Effect on Output Within ±0.003%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 700 Ω ±0.7%
Output Resistance 700 Ω ±0.7%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long , bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Ultimate Lateral Load 30 kN
(Max. load which does not cause any mechanical damage)
Weight Approx. 13 kg (Excluding calbe)
Materials Stainless steel
Degree of Protection IP67 (IEC 60529)

Dimensions

LCTS-B

Page Top

To Ensure Safe Usage

(Note 1) No LCTS-B is used for any onboard measurement.
(Note 2) No LCTS-B is used in an environment where it is frequently
exposed to lateral loads.
(Note 3) No LCTS-B is installed to any inclined or vertical surfaces.

To Ensure Safe Usage
∙ Accessories to Load Cells
Do not disassemble or remodel accessories such as top plate and mounting plate designed for
installation of LCTS-B series load cells.
∙ Installation of Floating Prevention Stoppers
Install the hazard prevention stopper when using in an environment where the load cell may be
damaged or the hopper or tank may overturn due to lateral loads or lateral displacement caused by thermal expansion of structure or vibration of stirrers.