LCV-A
Small-sized Compression Load Cell

  • CE

Summary

The LCV-A is a compact load cell for measuring compressive large loads. It is Easy installation into existing facilities. It is hermetically-sealed structure with inert gas filled in.
Rated Capacity: 500 kN, 1 MN
Diameter: 126 mm (500 kN), 146 mm (1 MN)
Nonlinearity: Within ±0.1% RO

Features

• High output
• Long cycle life: 10 million cycles or more
• BISELCOM® gages are used
* BISELCOM gages are self-temperature-compensation strain gages with the sensitivity-temperature-compensation function added.

Products table

All display

LCV-A-500KN
500 kN

  • CE

Specifications

Performance
Rated Capacity 500 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output 2.5 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm)
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 13 kHz
Weight Approx. 6 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Compliance Directive 2011/65/EU (RoHS)
Optional Accessories Saddle CA-B, CA-MH
Mount base CF

Dimensions

LCV-A-1MN
1 MN

  • CE

Specifications

Performance
Rated Capacity 1 MN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output 2.5 mV/V ±0.2%
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 20 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 350 Ω ±0.5%
Output Resistance 350 Ω ±0.5%
Cable 4-conductor (0.5 mm2) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with crimp-style terminals (For 4 mm)
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 12 kHz
Weight Approx. 10 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Compliance Directive 2011/65/EU (RoHS)
Optional Accessories Saddle CA-B, CA-MH
Mount base CF