LCX-A-ID
Small-sized Compression Load Cell

  • TEDS

LCX-A-ID

Summary

The LCX-A-ID is a stainless-steel load cell, for measuring compressive loads. It is compact & lightweight.
Rated Capacity: 500 N to 20 kN
Diameter: 28 mm (500 N to 2 kN), 43 mm (5 kN to 20 kN)
Nonlinearity: Within ±0.1% RO

Features

• Easily replace cables
• Exchange to a bending resistance cable possible
• TEDS installed

Products table

All display

LCX-A-500N-ID
500 N

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 500 N
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.0 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 24 kHz
Materials Stainless steel
Weight Approx. 45 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

LCX-A-1KN-ID
1 kN

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 1 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.5 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 29 kHz
Materials Stainless steel
Weight Approx. 45 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

LCX-A-2KN-ID
2 kN

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 2 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.5 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 37 kHz
Materials Stainless steel
Weight Approx. 45 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

LCX-A-5KN-ID
5 kN

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 5 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.5 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 24 kHz
Materials Stainless steel
Weight Approx. 120 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

LCX-A-10KN-ID
10 kN

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 10 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.5 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 28 kHz
Materials Stainless steel
Weight Approx. 120 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

LCX-A-20KN-ID
20 kN

LCX-A-ID
  • TEDS

Specifications

Performance
Rated Capacity 20 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output Within 1.5 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 70°C (Non-condensing)
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Cable Model: TE-45
6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Safe Lateral Loads 15% the rated capacity
Natural Frequencies Approx. 37 kHz
Materials Stainless steel
Weight Approx. 120 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Saddle CA
Mount base CX

Dimensions

LCX-A-ID

Mount Base

CX-5
Mount Base

CX-5
Object Product Model LCX-A-500N-ID
LCX-A-1KN-ID
LCX-A-2KN-ID
Weight (Approx.) Approx.100 g

CX-7
Mount Base

CX-7
Object Product Model LCX-A-500N-ID
LCX-A-1KN-ID
LCX-A-2KN-ID
Weight (Approx.) 280 g

CA-2F
Saddle

CA-2F
Object Product Model LCN-A
LCX-A-ID

Page Top

Remarks

Work is also possible if the cable is replaced with one resistant to repeated bending (flexible cable). Please add M1Z3K to the end of the model name.

eBook

Download

Recommended products for combination