LCX-A-ID
Small-sized Compression Load Cell

Summary
The LCX-A-ID is a stainless-steel load cell, for measuring compressive loads. It is compact & lightweight.
Rated Capacity: 500 N to 20 kN
Diameter: 28 mm (500 N to 2 kN), 43 mm (5 kN to 20 kN)
Nonlinearity: Within ±0.1% RO
Features
• Easily replace cables
• Exchange to a bending resistance cable possible
• TEDS installed
Products table
All display
LCX-A-500N-ID
500 N

Specifications
Performance
Rated Capacity | 500 N |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.0 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.01% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 24 kHz |
Materials | Stainless steel |
Weight | Approx. 45 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

LCX-A-1KN-ID
1 kN

Specifications
Performance
Rated Capacity | 1 kN |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 29 kHz |
Materials | Stainless steel |
Weight | Approx. 45 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

LCX-A-2KN-ID
2 kN

Specifications
Performance
Rated Capacity | 2 kN |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 37 kHz |
Materials | Stainless steel |
Weight | Approx. 45 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

LCX-A-5KN-ID
5 kN

Specifications
Performance
Rated Capacity | 5 kN |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 24 kHz |
Materials | Stainless steel |
Weight | Approx. 120 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

LCX-A-10KN-ID
10 kN

Specifications
Performance
Rated Capacity | 10 kN |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 28 kHz |
Materials | Stainless steel |
Weight | Approx. 120 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

LCX-A-20KN-ID
20 kN

Specifications
Performance
Rated Capacity | 20 kN |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.1% RO |
Repeatability | 0.05% RO or less |
Rated Output | Within 1.5 mV/V or more |
Environmental Characteristics
Safe Temperature | -20 to 80°C (Non-condensing) |
---|---|
Compensated Temperature | -10 to 70°C (Non-condensing) |
Temperature Effect on Zero | Within ±0.005% RO/ºC |
Temperature Effect on Output | Within ±0.005%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 375 Ω ±1.5% |
Output Resistance | 350 Ω ±1% |
Cable | Model: TE-45 6-conductor (0.08 mm2) chloroprene shielded cable,4.4 mm diameter by 3 m long Sensor side: Terminated with a connector plug 213FCW-8P Measuring instrument side: Bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Safe Lateral Loads | 15% the rated capacity |
Natural Frequencies | Approx. 37 kHz |
Materials | Stainless steel |
Weight | Approx. 120 g (Excluding cable) |
Degree of Protection | IP67 (IEC 60529) |
Optional Accessories | Saddle CA Mount base CX |
---|
Dimensions

Mount Base
CX-5
Mount Base

Object Product Model | LCX-A-500N-ID LCX-A-1KN-ID LCX-A-2KN-ID |
---|---|
Weight (Approx.) | Approx.100 g |
CX-7
Mount Base

Object Product Model | LCX-A-500N-ID LCX-A-1KN-ID LCX-A-2KN-ID |
---|---|
Weight (Approx.) | 280 g |
CA-2F
Saddle

Object Product Model | LCN-A LCX-A-ID |
---|
Remarks
Work is also possible if the cable is replaced with one resistant to repeated bending (flexible cable). Please add M1Z3K to the end of the model name.