The LMC-A is a compact & lightweight load cell for measuring compressive loads. Rated Capacity: 5 kN to 50 kN Diameter: 12±0.1mm (5, 10 kN), 16±0.1mm (20 kN), 22±0.2mm (50 kN) Nonlinearity: Within ±0.5% RO for 5 kN to 10 kN, within ±1% RO for 20 kN to 50 kN
Features
• High output and high accuracy • Easy installation • Suitable for loads measurement at limited place and weight
Products table
All display
LMC-A-5KN 5 kN
Specifications
Performance
Rated Capacity
5 kN
Nonlinearity
Within ±0.5% RO
Hysteresis
Within ±0.5% RO
Repeatability
0.5% RO or less
Rated Output
1.5 mV/V or more
Environmental Characteristics
Safe Temperature
-10 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
7 V AC or DC
Recommended Excitation
1 to 6 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 32 kHz
Weight
Approx. 5 g (Excluding cable)
Materials
Stainless steel
Degree of Protection
IP64 (IEC 60529)
Dimensions
LMC-A-10KN 10 kN
Specifications
Performance
Rated Capacity
10 kN
Nonlinearity
Within ±0.5% RO
Hysteresis
Within ±0.5% RO
Repeatability
0.5% RO or less
Rated Output
1.5 mV/V or more
Environmental Characteristics
Safe Temperature
-10 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
7 V AC or DC
Recommended Excitation
1 to 6 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 38 kHz
Weight
Approx. 6 g (Excluding cable)
Materials
Stainless steel
Degree of Protection
IP64 (IEC 60529)
Dimensions
LMC-A-20KN 20 kN
Specifications
Performance
Rated Capacity
20 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Repeatability
0.5% RO or less
Rated Output
1.5 mV/V or more
Environmental Characteristics
Safe Temperature
-10 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
7 V AC or DC
Recommended Excitation
1 to 6 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 41 kHz
Weight
Approx. 10 g (Excluding cable)
Materials
Stainless steel
Degree of Protection
IP64 (IEC 60529)
Dimensions
LMC-A-50KN 50 kN
Specifications
Performance
Rated Capacity
50 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Repeatability
0.5% RO or less
Rated Output
1.5 mV/V or more
Environmental Characteristics
Safe Temperature
-10 to 80ºC
Compensated Temperature
0 to 70ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
7 V AC or DC
Recommended Excitation
1 to 6 V AC or DC
Input Resistance
350 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.)
Compact large capacity load cells result in high surface pressure on the mounting surfaces under rated load. For the mount base material, use HRC40 or better metals such as SUS630-H900. Example of recommended materials ・ Patch material: HRC (35 to 38), SCM440, etc. ・ Installation Plane material: HRC40 or better,SUS630-H900 SCM440, etc.
Remarks
*Operating conditions may adversely affect characteristics.For details, see the instruction manual. *CE compliant models are available. Inquiries are welcome.