The LTA-C-S is a crane load cell developed as detectors for jib crane weighing systems and for general tension measurement.
Rated Capacity: 20 to 500 kN Diameter: 410 mm (20 kN), 430 mm (50 kN), 470 mm (100 kN), 540 mm (200 kN), 610 mm (300 kN), 670 mm (500 kN) Nonlinearity: Within ±1% RO
Features
• Easy handling • High reliability • High stability
Products table
All display
LTA-C-20KNS 20 kN
Specifications
Performance
Rated Capacity
20 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Ultimate Overloads
Approx. 500%
Safe Overloads
150%
Weight
Approx. 5 kg (Excluding cable)
Dimensions
LTA-C-50KNS 50 kN
Specifications
Performance
Rated Capacity
50 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Ultimate Overloads
Approx. 500%
Safe Overloads
150%
Weight
Approx. 5.5 kg (Excluding cable)
Dimensions
LTA-C-100KNS 100 kN
Specifications
Performance
Rated Capacity
100 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Ultimate Overloads
Approx. 500%
Safe Overloads
150%
Weight
Approx. 11 kg (Excluding cable)
Dimensions
LTA-C-200KNS 200 kN
Specifications
Performance
Rated Capacity
200 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Ultimate Overloads
Approx. 500%
Safe Overloads
150%
Weight
Approx. 21 kg (Excluding cable)
Dimensions
LTA-C-300KNS 300 kN
Specifications
Performance
Rated Capacity
300 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
Mechanical Properties
Ultimate Overloads
Approx. 500%
Safe Overloads
150%
Weight
Approx. 35 kg (Excluding cable)
Dimensions
LTA-C-500KNS 500 kN
Specifications
Performance
Rated Capacity
500 kN
Nonlinearity
Within ±1% RO
Hysteresis
Within ±1% RO
Rated Output
0.6 to 0.7 mV/V
Environmental Characteristics
Safe Temperature
-20 to 70ºC
Compensated Temperature
-10 to 60ºC
Temperature Effect on Zero
Within ±0.05% RO/ºC
Temperature Effect on Output
Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation
12 V AC or DC
Recommended Excitation
1 to 10 V AC or DC
Input Resistance
350 Ω ±5%
Output Resistance
350 Ω ±5%
Cable
4-conductor (0.75 mm2) chloroprene shielded cable, 10 mm diameter by 10 m long, with crimp-style terminals (For 4 mm) (Shield wire is not connected to the case.)
∙ Install the load cell carefully to avoid applying tensile and impact force to the cable and prevent the load cell from receiving bending or twisting force. ∙ Prepare a safety device such as a link against accidental hazards so that it supports loads in place of a broken load cell.